SearcharxivSearch

arXiv · 1307.5233

GeFRO: a New Charge Sensitive Amplifier Design with a Minimal Number of Front-end Components

Abstract

A new approach was developed for the design of front-end circuits for semiconductor radiation detectors. The readout scheme consists of a first stage made of only a few components located close to the detector, and of a remote second stage located far from the detector, several meters away. The second stage amplifies the signals from the first stage and closes the feedback loop to discharge the input node after each event. The circuit has two outputs: one gives a "fast" signal, with a bandwidth larger than 20 MHz, allowing to preserve the high frequency components of the detector signals, which may be useful for timing measurements, pile-up rejection or pulse shape discrimination. The second output gives a "slow" signal, whose gain depends only on the value of the feedback capacitor, as happens with a classic charge sensitive amplifier, allowing to obtain higher resolution and lower drift. The prototype was named GeFRO for Germanium front-end, and was tested with a BEGe detector from Canberra. The wide bandwidth of the "fast" signal gave a timing resolution of the order of 20 ns. The noise of the circuit at the "slow" output after a 10 us Gaussian shaping was close to 160 electrons RMS with an input capacitance of 26 pF.

Explore related subjects

Keep this discovery

BibTeXRIS

L. Cassina, C. Cattadori, A. Giachero, C. Gotti, M. Maino, G. Pessina. 2013-07-19. GeFRO: a New Charge Sensitive Amplifier Design with a Minimal Number of Front-end Components. https://arxiv.org/abs/1307.5233

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det