Searcharxiv⌕ Search

arXiv subjects

M. Silarski

Publications and source records attributed to M. Silarski.

At least 55 records · Page 3Linked to original sources

Measurement of the charge asymmetry for the $K_S \rightarrow πe ν$ decay and test of CPT symmetry with the KLOE detector

Using 1.63 fb$^{-1}$ of integrated luminosity collected by the KLOE experiment about $7\times 10^4$ $K_S \rightarrow π^{\pm}e^{\mp}ν$ decays have been reconstructed. The measured value of the charge asymmetry for this decay is $A_S = (-4.9 \pm 5.7_{stat} \pm 2.6_{syst}) \times 10^{-3}$, which is almost twice more precise than the previous KLOE result. The combination of these two measurements gives $A_S = (-3.8 \pm 5.0_{stat} \pm 2.6_{syst}) \times 10^{-3}$ and, together with the asymmetry of the $K_L$ semileptonic decay, provides significant tests of the CPT symmetry. The obtained results are in agreement with CPT invariance.

hep-ex↗

Combined limit on the production of a light gauge boson decaying into $μ^+μ^-$ and $π^+π^-$

We searched for the $μ^+μ^-$ decay of a light vector gauge boson, also known as dark photon, in the $e^+ e^- \to μ^+ μ^- γ_{\rm ISR}$ process by means of the Initial State Radiation (ISR) method. We used 1.93~fb$^{-1}$ of data collected by the KLOE experiment at the DA$Φ$NE $ϕ$-factory. No structures have been observed over the irreducible $μ^+ μ^-$ background. A 90\% CL limit on the ratio $\varepsilon^2=α^{\prime}/α$ between the dark coupling constant and the fine structure constant of $ 3\times 10^{-6}-2\times 10^{-7}$ has been set in the dark photon mass region between 519 MeV and 973 MeV. This new limit has been combined with the published result obtained investigating the hypothesis of the dark photon decaying into hadrons in $e^+ e^- \to π^+ π^- γ_{\rm ISR}$ events. The combined 90\% CL limit increases the sensitivity especially in the $ρ-ω$ interference region and excludes $\varepsilon^2$ greater than $(13-2)\times 10^{-7}$. For dark photon masses greater than 600 MeV the combined limit is lower than 8~$\times\, 10^{-7}$ resulting more stringent than present constraints from other experiments.

hep-ex↗

Evaluation of Single-Chip, Real-Time Tomographic Data Processing on FPGA - SoC Devices

A novel approach to tomographic data processing has been developed and evaluated using the Jagiellonian PET (J-PET) scanner as an example. We propose a system in which there is no need for powerful, local to the scanner processing facility, capable to reconstruct images on the fly. Instead we introduce a Field Programmable Gate Array (FPGA) System-on-Chip (SoC) platform connected directly to data streams coming from the scanner, which can perform event building, filtering, coincidence search and Region-Of-Response (ROR) reconstruction by the programmable logic and visualization by the integrated processors. The platform significantly reduces data volume converting raw data to a list-mode representation, while generating visualization on the fly.

physics.ins-det↗

Combination of KLOE $σ\big(e^+e^-\rightarrowπ^+π^-γ(γ)\big)$ measurements and determination of $a_μ^{π^+π^-}$ in the energy range $0.10 < s < 0.95$ GeV$^2$

The three precision measurements of the cross section $σ\big(e^+e^-\rightarrowπ^+π^-γ(γ)\big)$ using initial state radiation by the KLOE collaboration provide an important input for the prediction of the hadronic contribution to the anomalous magnetic moment of the muon. These measurements are correlated for both statistical and systematic uncertainties and, therefore, the simultaneous use of these measurements requires covariance matrices that fully describe the correlations. We present the construction of these covariance matrices and use them to determine a combined KLOE measurement for $σ\big(e^+e^-\rightarrowπ^+π^-γ(γ)\big)$. We find, from this combination, a two-pion contribution to the muon magnetic anomaly in the energy range $0.10 < s < 0.95$ GeV$^2$ of $a_μ^{π^+π^-} = (489.8 \pm 1.7_{\rm stat} \pm 4.8_{\rm sys} ) \times 10^{-10}$.

hep-ex↗

Feasibility study of the time reversal symmetry tests in decays of metastable positronium atoms with the J-PET detector

This article reports on the feasibility of testing of the symmetry under reversal in time in a purely leptonic system constituted by positronium atoms using the J-PET detector. The present state of T symmetry tests is discussed with an emphasis on the scarcely explored sector of leptonic systems. Two possible strategies of searching for manifestations of T violation in non-vanishing angular correlations of final state observables in the decays of metastable triplet states of positronium available with J-PET are proposed and discussed. Results of a pilot measurement with J-PET and assessment of its performance in reconstruction of three-photon decays are shown along with an analysis of its impact on the sensitivity of the detector for the determination of T -violation sensitive observables.

physics.ins-det↗

The kaonic atoms research program at DAΦNE: from SIDDHARTA to SIDDHARTA-2

The interaction of antikaons with nucleons and nuclei in the low-energy regime represents an active research field in hadron physics with still many important open questions. The investigation of light kaonic atoms, in which one electron is replaced by a negatively charged kaon, is a unique tool to provide precise information on this interaction; the energy shift and the broadening of the low-lying states of such atoms, induced by the kaon-nucleus hadronic interaction, can be determined with high precision from the atomic X-ray spectroscopy, and this experimental method provides unique information to understand the low energy kaon-nucleus interaction at the production threshold. The lightest atomic systems, like the kaonic hydrogen and the kaonic deuterium deliver, in a model-independent way, the isospin-dependent kaon-nucleon scattering lengths. The most precise kaonic hydrogen measurement to-date, together with an exploratory measurement of kaonic deuterium, were carried out in 2009 by the SIDDHARTA collaboration at the DAΦNE electron-positron collider of LNF-INFN, combining the excellent quality kaon beam delivered by the collider with new experimental techniques, as fast and very precise X-ray detectors, like the Silicon Drift Detectors. The SIDDHARTA results triggered new theoretical work, which achieved major progress in the understanding of the low-energy strong interaction with strangeness reflected by the antikaon-nucleon scattering lengths calculated with the antikaon-proton amplitudes constrained by the SIDDHARTA data. The most important open question is the experimental determination of the hadronic energy shift and width of kaonic deuterium; presently, a major upgrade of the setup, SIDDHARTA-2, is being realized to reach this goal. In this paper, the results obtained in 2009 and the proposed SIDDHARTA-2 upgrades are presented.

nucl-ex↗

Towards 2+1 photon tomography: Energy-based selection of two 511 keV photons and a prompt photon with the J-PET scanner

The possibility to separate signals caused by 511 keV photons created in annihilation of electron-positron pairs and the so-called prompt photons from nuclei de- excitation is investigated. It could potentially be used to improve the quality of reconstructed images in the J-PET scanner in 2+1 photon tomography. Firstly, a research is conducted for several radioisotopes that decay via \b{eta}+ decay followed by de-excitation of an excited nucleus. Efficiency, purity and false positive rate are calculated for each isotope as a function of energy deposited threshold, with a hypothesis that signals caused by 511 keV photons deposit smaller values of energy than 1 z 13the selected threshold, while prompt photons deposit larger energy than the threshold. Analysis of the results accompanied with physical properties of radioisotopes suggests using 44 Sc, which is the most promising candidate for medical applications. With the use of GATE and J-POS simulation software, in-phantom scattering was introduced and the best energy deposited threshold value was estimated to be approximately 375 keV. It corresponds to almost 100% efficiency for 511 keV signals, 75% purity for 511 keV photons, and approximately 70% efficiency and purity for prompt photons.

physics.med-ph↗

Underwater detection of dangerous substances: status the SABAT project

The Neutron Activation Analysis (NAA) plays an exceptional role in the modern nuclear engineering, especially in detection of hazardous substances. However, in the aquatic environment, there are still many problems to be solved for effective usage of this technique. We present status of SABAT (Stoichiometry Analysis By Activation Techniques), one of the projects aiming at construction of an underwater device for non-invasive threat detection based on the NAA.

physics.ins-det↗

Human Tissues Investigation Using PALS Technique

Samples of uterine leiomyomatis and normal tissues taken from patients after surgery were investigated using the Positron Annihilation Lifetime Spectroscopy (PALS). Significant differences in all PALS parameters between normal and diseased tissues were observed. For all studied patients, it was found that the values of the free annihilation and ortho-positronium lifetime are larger for the tumorous tissues than for the healthy ones. For most of the patients, the intensity of the free annihilation and ortho-positronium annihilation was smaller for the tumorous than for the healthy tissues. For the first time, in this kind of studies, the $3γ$ fraction of positron annihilation was determined to describe changes in the tissue porosity during morphologic alteration.

physics.med-ph↗

Commissioning of the J-PET detector for studies of decays of positronium atoms

The Jagiellonian Positron Emission Tomograph (J-PET) is a detector for medical imaging of the whole human body as well as for physics studies involving detection of electron-positron annihilation into photons. J-PET has high angular and time resolution and allows for measurement of spin of the positronium and the momenta and polarization vectors of annihilation quanta. In this article, we present the potential of the J-PET system for background rejection in the decays of positronium atoms.

physics.ins-det↗

J-PET: a new technology for the whole-body PET imaging

The Jagiellonian Positron Emission Tomograph (J-PET) is the first PET built from plastic scintillators. J-PET prototype consists of 192 detection modules arranged axially in three layers forming a cylindrical diagnostic chamber with the inner diameter of 85 cm and the axial field-of-view of 50 cm. An axial arrangement of long strips of plastic scintillators, their small light attenuation, superior timing properties, and relative ease of the increase of the axial field-of-view opens promising perspectives for the cost effective construction of the whole-body PET scanner, as well as construction of MR and CT compatible PET inserts. Present status of the development of the J-PET tomograph will be presented and discussed.

physics.ins-det↗

Introduction of total variation regularization into filtered backprojection algorithm

In this paper we extend the state-of-the-art filtered backprojection (FBP) method with application of the concept of Total Variation regularization. We compare the performance of the new algorithm with the most common form of regularizing in the FBP image reconstruction via apodizing functions. The methods are validated in terms of cross-correlation coefficient between reconstructed and real image of radioactive tracer distribution using standard Derenzo-type phantom. We demonstrate that the proposed approach results in higher cross-correlation values with respect to the standard FBP method.

physics.med-ph↗

Three-dimensional image reconstruction in J-PET using Filtered Back Projection method

We present a method and preliminary results of the image reconstruction in the Jagiellonian PET tomograph. Using GATE (Geant4 Application for Tomographic Emission), interactions of the 511 keV photons with a cylindrical detector were generated. Pairs of such photons, flying back-to-back, originate from e+e- annihilations inside a 1-mm spherical source. Spatial and temporal coordinates of hits were smeared using experimental resolutions of the detector. We incorporated the algorithm of the 3D Filtered Back Projection, implemented in the STIR and TomoPy software packages, which differ in approximation methods. Consistent results for the Point Spread Functions of ~5/7,mm and ~9/20, mm were obtained, using STIR, for transverse and longitudinal directions, respectively, with no time of flight information included.

physics.ins-det↗

Analysis procedure of the positronium lifetime spectra for the J-PET detector

Positron Annihilation Lifetime Spectroscopy (PALS) has shown to be a powerful tool to study the nanostructures of porous materials. Positron Emissions Tomography (PET) are devices allowing imaging of metabolic processes e.g. in human bodies. A newly developed device, the J-PET (Jagiellonian PET), will allow PALS in addition to imaging, thus combining both analyses providing new methods for physics and medicine. In this contribution we present a computer program that is compatible with the J-PET software. We compare its performance with the standard program LT 9.0 by using PALS data from hexane measurements at different temperatures. Our program is based on an iterative procedure, and our fits prove that it performs as good as LT 9.0.

physics.ins-det↗

Time calibration of the J-PET detector

The Jagiellonian Positron Emission Tomograph (J-PET) project carried out in the Institute of Physics of the Jagiellonian University is focused on construction and tests of the first prototype of PET scanner for medical diagnostic which allows for the simultaneous 3D imaging of the whole human body using organic scintillators. The J-PET prototype consists of 192 scintillator strips forming three cylindrical layers which are optimized for the detection of photons from the electron-positron annihilation with high time- and high angular-resolutions. In this article we present time calibration and synchronization of the whole J-PET detection system by irradiating each single detection module with a 22Na source and a small detector providing common reference time for synchronization of all the modules.

physics.ins-det↗

Calculation of time resolution of the J-PET tomograph using the Kernel Density Estimation

In this paper we estimate the time resolution of the J-PET scanner built from plastic scintillators. We incorporate the method of signal processing using the Tikhonov regularization framework and the Kernel Density Estimation method. We obtain simple, closed-form analytical formulas for time resolutions. The proposed method is validated using signals registered by means of the single detection unit of the J-PET tomograph built out from 30 cm long plastic scintillator strip. It is shown that the experimental and theoretical results, obtained for the J-PET scanner equipped with vacuum tube photomultipliers, are consistent.

physics.ins-det↗

Multichannel FPGA based MVT system for high precision time (20~ps~RMS) and charge measurement

In this article it is presented an FPGA based $M$ulti-$V$oltage $T$hreshold (MVT) system which allows of sampling fast signals ($1-2$ ns rising and falling edge) in both voltage and time domain. It is possible to achieve a precision of time measurement of $20$ ps RMS and reconstruct charge of signals, using a simple approach, with deviation from real value smaller than 10$\%$. Utilization of the differential inputs of an FPGA chip as comparators together with an implementation of a TDC inside an FPGA allowed us to achieve a compact multi-channel system characterized by low power consumption and low production costs. This paper describes realization and functioning of the system comprising 192-channel TDC board and a four mezzanine cards which split incoming signals and discriminate them. The boards have been used to validate a newly developed Time-of-Flight Positron Emission Tomography system based on plastic scintillators. The achieved full system time resolution of $σ$(TOF) $\approx 68$ ps is by factor of two better with respect to the current TOF-PET systems.

physics.ins-det↗