SearcharxivSearch

arXiv subjects

M. Tzanov

Publications and source records attributed to M. Tzanov.

At least 19 recordsLinked to original sources

Total Neutron Cross-section Measurement on CH with a Novel 3D-projection Scintillator Detector

In order to extract neutrino oscillation parameters, precision long-baseline neutrino oscillation experiments rely on detailed models of neutrino interactions with nuclei. These models constitute an important source of systematic uncertainty, partially because detectors to date have been blind to final state neutrons. Three-dimensional projection scintillator trackers comprise components of the near detectors of the next generation long-baseline neutrino experiments. Due to the good timing resolution and fine granularity, this technology is capable of measuring neutron kinetic energy in neutrino interactions on an event-by-event basis and will provide valuable data for refining neutrino interaction models and ways to reconstruct neutrino energy. Two prototypes have been exposed to the neutron beamline at Los Alamos National Laboratory (LANL) in both 2019 and 2020, with neutron energies between 0 and 800 MeV. In order to demonstrate the capability of neutron detection, the total neutron-scintillator cross section is measured and compared to external measurements. The measured total neutron cross section in scintillator between 98 and 688 MeV is 0.36 $\pm$ 0.05 barn.

physics.ins-det

Measurement of the Neutron Cross Section on Argon Between 95 and 720 MeV

We report an extended measurement of the neutron cross section on argon in the energy range of 95-720 MeV. The measurement was obtained with a 4.3-hour exposure of the Mini-CAPTAIN detector to the WNR/LANSCE beam at LANL. Compared to an earlier analysis of the same data, this extended analysis includes a reassessment of systematic uncertainties, in particular related to unused wires in the upstream part of the detector. Using this information we doubled the fiducial volume in the experiment and increased the statistics by a factor of 2.4. We also shifted the analysis from energy bins to time-of-flight bins. This change reduced the overall considered energy range, but improved the understanding of the energy spectrum of incoming neutrons in each bin. Overall, the new measurements are extracted from a fit to the attenuation of the neutron flux in five time-of-flight regions: 140 ns - 180 ns, 120 ns - 140 ns, 112 ns - 120 ns, 104 ns - 112 ns, 96 ns - 104 ns. The final cross sections are given for the flux-averaged energy in each time-of-flight bin: $σ(146~\rm{MeV})=0.60^{+0.14}_{-0.14}\pm0.08$(syst) b, $σ(236~\rm{MeV})=0.72^{+0.10}_{-0.10}\pm0.04$(syst) b, $σ(319~\rm{MeV})=0.80^{+0.13}_{-0.12}\pm0.040$(syst) b, $σ(404~\rm{MeV})=0.74^{+0.14}_{-0.09}\pm0.04$(syst) b, $σ(543~\rm{MeV})=0.74^{+0.09}_{-0.09}\pm0.04$(syst) b.

nucl-ex

SuperFGD prototype time resolution studies

The SuperFGD will be a part of the ND280 near detector of the T2K and Hyper Kamiokande projects, that will help to reduce systematic uncertainties related with neutrino flux and cross-section modeling. The upgraded ND280 will be able to perform a full exclusive reconstruction of the final state from neutrino-nucleus interactions, including measurements of low momentum protons, pions and, for the first time, event-by event measurements of neutron kinematics. The time resolution defines the neutron energy resolution. We present the results of time resolution measurements made with the SuperFGD prototype that consists of 9216 plastic scintillator cubes (cube size is 1 cm$^3$) readout with 1728 wavelength-shifting fibers going along three orthogonal directions. We use data from the muon beam exposure at CERN. The time resolution of 0.97 ns was obtained for one readout channel after implementing the time calibration with a correction for the time-walk effect. The time resolution improves with energy deposited in a scintillator cube. Averaging two readout channels for one scintillator cube improves the time resolution to 0.68 ns which means that signals in different channels are not synchronous. Therefore the contribution from the time recording step of 2.5 ns is averaged as well. Averaging time values from N channels improves the time resolution by $\sim 1/\sqrt{N}$. Therefore a very good time resolution should be achievable for neutrons since neutron recoils hit typically several scintillator cubes and in addition produce larger amplitudes than muons. Measurements performed with a laser and a wide-bandwidth oscilloscope demonstrated that the time resolution obtained with the muon beam is not far from its expected limit. The intrinsic time resolution of one channel is 0.67 ns for signals of 56 photo-electron typical for minimum ionizing particles.

physics.ins-det

Neutron detection and application with a novel 3D-projection scintillator tracker in the future long-baseline neutrino oscillation experiments

Neutrino oscillation experiments require a precise measurement of the neutrino energy. However, the kinematic detection of the final-state neutron in the neutrino interaction is missing in current neutrino oscillation experiments. The missing neutron kinematic detection results in a feed-down of the detected neutrino energy compared to the true neutrino energy. A novel 3D\textcolor{black}{-}projection scintillator tracker, which consists of roughly ten million active cubes covered with an optical reflector, is capable of measuring the neutron kinetic energy and direction on an event-by-event basis using the time-of-flight technique thanks to the fast timing, fine granularity, and high light yield. The $\barν_μ$ interactions tend to produce neutrons in the final state. By inferring the neutron kinetic energy, the $\barν_μ$ energy can be reconstructed better, allowing a tighter incoming neutrino flux constraint. This paper shows the detector's ability to reconstruct neutron kinetic energy and the $\barν_μ$ flux constraint achieved by selecting the charged-current interactions without mesons or protons in the final state.

hep-ex

MiniBooNE and MicroBooNE Combined Fit to a 3+1 Sterile Neutrino Scenario

This letter presents the results from the MiniBooNE experiment within a full "3+1" scenario where one sterile neutrino is introduced to the three-active-neutrino picture. In addition to electron-neutrino appearance at short-baselines, this scenario also allows for disappearance of the muon-neutrino and electron-neutrino fluxes in the Booster Neutrino Beam, which is shared by the MicroBooNE experiment. We present the 3+1 fit to the MiniBooNE electron-(anti)neutrino and muon-(anti)neutrino data alone, and in combination with MicroBooNE electron-neutrino data. The best-fit parameters of the combined fit with the exclusive CCQE analysis (inclusive analysis) are $Δm^2 = 0.29 eV^2 (0.33 eV^2)$, $|U_{e4}|^2 = 0.016 (0.500)$, $|U_{μ4}|^2 = 0.500 (0.500)$, and $\sin^2(2θ_{μe})=0.0316 (1.0)$. Comparing the no-oscillation scenario to the 3+1 model, the data prefer the 3+1 model with a $Δχ^2/\text{dof} = 24.7 / 3 (17.3 / 3)$, a $4.3σ(3.4σ)$ preference assuming the asymptotic approximation given by Wilks' theorem.

hep-ex

Measurement of the ($π^-$, Ar) total hadronic cross section at the LArIAT experiment

We present the first measurement of the negative pion total hadronic cross section on argon, which we performed at the Liquid Argon In A Testbeam (LArIAT) experiment. All hadronic reaction channels, as well as hadronic elastic interactions with scattering angle greater than 5~degrees are included. The pions have a kinetic energies in the range 100-700~MeV and are produced by a beam of charged particles impinging on a solid target at the Fermilab Test Beam Facility. LArIAT employs a 0.24~ton active mass Liquid Argon Time Projection Chamber (LArTPC) to measure the pion hadronic interactions. For this measurement, LArIAT has developed the ``thin slice method", a new technique to measure cross sections with LArTPCs. While generally higher than the prediction, our measurement of the ($π^-$,Ar) total hadronic cross section is in agreement with the prediction of the Geant4 model when considering a model uncertainty of $\sim$5.1\%.

hep-ex

MiniBooNE Data Releases

The MiniBooNE experiment has provided data releases for most publications. Occasionally it is necessary to move data release pages. This document provides a single point of reference that will be updated by the collaboration to point to the present location of the MiniBooNE data releases.

hep-ex

Updated MiniBooNE Neutrino Oscillation Results with Increased Data and New Background Studies

The MiniBooNE experiment at Fermilab reports a total excess of $638.0 \pm 132.8$ electron-like events ($4.8 σ$) from a data sample corresponding to $18.75 \times 10^{20}$ protons-on-target in neutrino mode, which is a 46\% increase in the data sample with respect to previously published results, and $11.27 \times 10^{20}$ protons-on-target in antineutrino mode. The additional statistics allow several studies to address questions on the source of the excess. First, we provide two-dimensional plots in visible energy and cosine of the angle of the outgoing lepton, which can provide valuable input to models for the event excess. Second, we test whether the excess may arise from photons that enter the detector from external events or photons exiting the detector from $π^0$ decays in two model independent ways. Beam timing information shows that almost all of the excess is in time with neutrinos that interact in the detector. The radius distribution shows that the excess is distributed throughout the volume, while tighter cuts on the fiducal volume increase the significance of the excess. We conclude that models of the event excess based on entering and exiting photons are disfavored.

hep-ex

Theia: An advanced optical neutrino detector

New developments in liquid scintillators, high-efficiency, fast photon detectors, and chromatic photon sorting have opened up the possibility for building a large-scale detector that can discriminate between Cherenkov and scintillation signals. Such a detector could exploit these two distinct signals to observe particle direction and species using Cherenkov light while also having the excellent energy resolution and low threshold of a scintillator detector. Situated in a deep underground laboratory, and utilizing new techniques in computing and reconstruction techniques, such a detector could achieve unprecedented levels of background rejection, thus enabling a rich physics program that would span topics in nuclear, high-energy, and astrophysics, and across a dynamic range from hundreds of keV to many GeV. The scientific program would include observations of low- and high-energy solar neutrinos, determination of neutrino mass ordering and measurement of the neutrino CP violating phase, observations of diffuse supernova neutrinos and neutrinos from a supernova burst, sensitive searches for nucleon decay and, ultimately, a search for NeutrinoLess Double Beta Decay (NLDBD) with sensitivity reaching the normal ordering regime of neutrino mass phase space. This paper describes Theia, a detector design that incorporates these new technologies in a practical and affordable way to accomplish the science goals described above. We consider two scenarios, one in which Theia would reside in a cavern the size and shape of the caverns intended to be excavated for the Deep Underground Neutrino Experiment (DUNE) which we call Theia 25, and a larger 100 ktonne version (Theia 100) that could achieve an even broader and more sensitive scientific program.

physics.ins-det

The Mini-CAPTAIN Liquid Argon Time Projection Chamber

This manuscript describes the commissioning of the Mini-CAPTAIN liquid argon detector in a neutron beam at the Los Alamos Neutron Science Center (LANSCE), which led to a first measurement of high-energy neutron interactions in argon. The Mini-CAPTAIN detector consists of a Time Projection Chamber (TPC) with an accompanying photomultiplier tube (PMT) array sealed inside a liquid-argon-filled cryostat. The liquid argon is constantly purified and recirculated in a closed-loop cycle during operation. The specifications and assembly of the detector subsystems and an overview of their performance in a neutron beam are reported.

physics.ins-det

The ProtoDUNE-SP LArTPC Electronics Production, Commissioning, and Performance

The ProtoDUNE-SP detector is a large-scale prototype of the Single-Phase (SP) Liquid Argon Time Projection Chamber (LArTPC) design proposed for the Deep Underground Neutrino Experiment (DUNE). 15,360 LArTPC wires are instrumented with low electronic noise pre-amplifier and digitization ASICs integrated into Front End Motherboards (FEMBs) operating at cryogenic temperature within the cryostat. The large number of electronics channels and high performance specifications required a large-scale production electronics quality control effort, careful installation into Anode Plane Assemblies (APAs), and rigorous detector commissioning. This successful collaboration-wide effort achieved a working LArTPC electronics channel percentage of 99.7% (15,318 of 15,360 channels in total), whose operating performance exceeded expectations. We summarize the ProtoDUNE-SP cold electronics design and quality control, installation, and commissioning efforts that enabled this excellent electronics performance.

physics.ins-det

The Liquid Argon In A Testbeam (LArIAT) Experiment

The LArIAT liquid argon time projection chamber, placed in a tertiary beam of charged particles at the Fermilab Test Beam Facility, has collected large samples of pions, muons, electrons, protons, and kaons in the momentum range 300-1400 MeV/c. This paper describes the main aspects of the detector and beamline, and also reports on calibrations performed for the detector and beamline components.

physics.ins-det

Calorimetry for low-energy electrons using charge and light in liquid argon

Precise calorimetric reconstruction of 5-50 MeV electrons in liquid argon time projection chambers (LArTPCs) will enable the study of astrophysical neutrinos in DUNE and could enhance the physics reach of oscillation analyses. Liquid argon scintillation light has the potential to improve energy reconstruction for low-energy electrons over charge-based measurements alone. Here we demonstrate light-augmented calorimetry for low-energy electrons in a single-phase LArTPC using a sample of Michel electrons from decays of stopping cosmic muons in the LArIAT experiment at Fermilab. Michel electron energy spectra are reconstructed using both a traditional charge-based approach as well as a more holistic approach that incorporates both charge and light. A maximum-likelihood fitter, using LArIAT's well-tuned simulation, is developed for combining these quantities to achieve optimal energy resolution. A sample of isolated electrons is simulated to better determine the energy resolution expected for astrophysical electron-neutrino charged-current interaction final states. In LArIAT, which has very low wire noise and an average light yield of 18 pe/MeV, an energy resolution of $σ/E \simeq 9.3\%/\sqrt{E} \oplus 1.3\%$ is achieved. Samples are then generated with varying wire noise levels and light yields to gauge the impact of light-augmented calorimetry in larger LArTPCs. At a charge-readout signal-to-noise of S/N $\simeq$ 30, for example, the energy resolution for electrons below 40 MeV is improved by $\approx$ 10%, $\approx$ 20%, and $\approx$ 40% over charge-only calorimetry for average light yields of 10 pe/MeV, 20 pe/MeV, and 100 pe/MeV, respectively.

physics.ins-det

First Measurement of the Total Neutron Cross Section on Argon Between 100 and 800 MeV

We report the first measurement of the neutron cross section on argon in the energy range of 100-800 MeV. The measurement was obtained with a 4.3-hour exposure of the Mini-CAPTAIN detector to the WNR/LANSCE beam at LANL. The total cross section is measured from the attenuation coefficient of the neutron flux as it traverses the liquid argon volume. A set of 2,631 candidate interactions is divided in bins of the neutron kinetic energy calculated from time-of-flight measurements. These interactions are reconstructed with custom-made algorithms specifically designed for the data in a time projection chamber the size of the Mini-CAPTAIN detector. The energy averaged cross section is $0.91 \pm{} 0.10~\mathrm{(stat.)} \pm{} 0.09~\mathrm{(sys.)}~\mathrm{barns}$. A comparison of the measured cross section is made to the GEANT4 and FLUKA event generator packages.

hep-ex

Significant Excess of ElectronLike Events in the MiniBooNE Short-Baseline Neutrino Experiment

The MiniBooNE experiment at Fermilab reports results from an analysis of $ν_e$ appearance data from $12.84 \times 10^{20}$ protons on target in neutrino mode, an increase of approximately a factor of two over previously reported results. A $ν_e$ charged-current quasielastic event excess of $381.2 \pm 85.2$ events ($4.5 σ$) is observed in the energy range $200<E_ν^{QE}<1250$~MeV. Combining these data with the $\bar ν_e$ appearance data from $11.27 \times 10^{20}$ protons on target in antineutrino mode, a total $ν_e$ plus $\bar ν_e$ charged-current quasielastic event excess of $460.5 \pm 99.0$ events ($4.7 σ$) is observed. If interpreted in a two-neutrino oscillation model, $ν_μ \rightarrow ν_e$, the best oscillation fit to the excess has a probability of $21.1\%$, while the background-only fit has a $χ^2$ probability of $6 \times 10^{-7}$ relative to the best fit. The MiniBooNE data are consistent in energy and magnitude with the excess of events reported by the Liquid Scintillator Neutrino Detector (LSND), and the significance of the combined LSND and MiniBooNE excesses is $6.0 σ$. A two-neutrino oscillation interpretation of the data would require at least four neutrino types and indicate physics beyond the three neutrino paradigm.Although the data are fit with a two-neutrino oscillation model, other models may provide better fits to the data.

hep-ex

Development and operational experience of magnetic horn system for T2K experiment

A magnetic horn system to be operated at a pulsed current of 320 kA and to survive high-power proton beam operation at 750 kW was developed for the T2K experiment. The first set of T2K magnetic horns was operated for over 12 million pulses during the four years of operation from 2010 to 2013, under a maximum beam power of 230 kW, and $6.63\times10^{20}$ protons were exposed to the production target. No significant damage was observed throughout this period. This successful operation of the T2K magnetic horns led to the discovery of the $ν_μ\rightarrowν_e$ oscillation phenomenon in 2013 by the T2K experiment. In this paper, details of the design, construction, and operation experience of the T2K magnetic horns are described.

physics.ins-det

LArIAT: Liquid Argon In A Testbeam

Liquid Argon Time Projection Chambers (LArTPCs) are ideal detectors for precision neutrino physics. These detectors, when located deep underground, can also be used for measurements of proton decay, and astrophysical neutrinos. The technology must be completely developed, up to very large mass scales, and fully mastered to construct and operate these detectors for this physics program. As part of an integrated plan of developing these detectors, accurate measurements in LArTPC of known particle species in the relevant energy ranges are now deemed as necessary. The LArIAT program aims to directly achieve these goals by deploying LArTPC detectors in a dedicated calibration test beam line at Fermilab. The set of measurements envisaged here are significant for both the short-baseline (SBN) and long-baseline (LBN) neutrino oscillation programs in the US, starting with MicroBooNE in the near term and with the adjoint near and far liquid argon detectors in the Booster beam line at Fermilab envisioned in the mid-term, and moving towards deep underground physics such as with the long-baseline neutrino facility (LBNF) in the longer term.

physics.ins-det