SearcharxivSearch

arXiv subjects

M. Y. Guan

Publications and source records attributed to M. Y. Guan.

At least 19 recordsLinked to original sources

A study of liquid argon detector's $n$/$γ$ discrimination capability with PMT or SiPM readout

Liquid Argon (LAr) is used as a target material in several current and planned experiments related to dark matter direct searching and neutrino detection. Argon provides excellent Pulse Shape Discrimination (PSD) capability which could separate the electron recoil backgrounds from the expected nuclear recoil signals. This essay simulated the PSD capability of an LAr detector when PMTs or three kinds of SiPMs are used as photosensors based on the experimental data. The results show that the J-60035 SiPM could help the LAr detector achieve the highest PSD capability event though SiPM's After-Pulse (AP) and Cross-Talk (CT) deteriorate its PSD capability. In addition, the results also show that the effect from AP is greater than CT. This is instructive for selecting photosensors for LAr detectors.

physics.ins-det

Analysis of signal waveform from a midsize liquid argon detetor

The midsize single-phase liquid argon prototype detector, operating at the surface laboratory, is designed to measure scintillation light emitted by the liquid argon (LAr). The detector employs 42 8-inch photomultiplier tubes (PMT) to collect the light. By analyzing the waveform of the signal, important detector characteristics such as the slow decay time constant that characterizes the purity of the liquid argon can be obtained. To describe the signal waveform, a model that considers the TPB re-emission process and the signal reflection effects based on the principles of liquid argon light emission, including fast and slow components of light decay, is used. The TPB re-emission process is introduced using a three-exponential time structure. Additionally, experimental results provide comprehensive validation for a post-peak hump structure, which is attributed to signal reflection.

physics.ins-det

Characterization of two SiPM arrays from Hamamatsu and Onsemi for liquid argon detector

Silicon photomultiplier (SiPM), a new type of photosensor, is considered a substitute for traditional photomultiplier tube (PMT) in the next generation of dark matter and neutrino detectors, especially in noble gas detectors like liquid argon. However, the design of compact SiPM arrays and their cryogenic electronics that can work in liquid argon is barely developed. Thus, two candidate SiPM arrays from Hamamatsu and Onsemi were selected to verify the feasibility and effectiveness of the design. In this work, we successfully developed a cryogenic electronics read-out system that connects and works with 1-inch 4$\times$4 SiPM arrays at 87~K. The power dissipation of amplifiers is less than 10 $μ$W/mm$^2$. Furthermore, multiply significant characteristics of both types of SiPM arrays were measured at liquid argon temperature, such as dark count rate (DCR), breakdown voltage (V${_{bd}}$), single photoelectron (SPE) performance, signal to noise ratio (SNR) and correlated signal probability.

physics.ins-det

Characterization of VUV4 SiPM for Liquid Argon Detector

Particle detectors based on liquid argon are now recognised as an attractive technology for dark matter direct detection and coherent elastic neutrino-nucleus scattering measurement. A program using a dual-phase liquid argon detector with a fiducial mass of 200~kg to detect coherent elastic neutrino-nucleus scattering at Taishan Nuclear Power Plant has been proposed. SiPMs will be used as the photon sensor because of their high radio-purity and high photon detection efficiency. S13370-6050CN SiPM, made by Hamamatsu, is a candidate for the detector. In this paper, the characterisation of S13370-6050CN SiPM, including the cross talk and after pulse probabilities at liquid argon temperature and the temperature dependence of break down voltage, dark counting rate and relative quantum efficiency were presented.

physics.ins-det

Using $^{22}$Na and $^{83{\rm m}}$Kr to calibrate and study the properties of scintillation in xenon-doped liquid argon

We have measured the properties of scintillation light in liquid argon doped with xenon concentrations from 165 ppm to 10,010 ppm using a $^{22}$Na source. The energy transfer processes in the xenon-doped liquid argon are discussed in detail, and a new waveform model is established and used to fit the average waveform. The time profile of the scintillation photon in the xenon-doped liquid argon and of the TPB emission are presented. The quantities of xenon-doped are controlled by a Mass Flow Controller which is calibrated via a Redusial Gas Analyzer to ensure that the xenon concentration is accurate. In addition, a successful test of $^{83{\rm m}}$Kr as a calibration source has been implemented in the xenon-doped liquid argon detector for the first time. By comparing the light yield of the $^{22}$Na and $^{83{\rm m}}$Kr, it can be concluded that the scintillation efficiency is almost same over the range of 41.5 keV to 511 keV.

physics.ins-det

The development of $^{222}$Rn detectors for JUNO prototype

The radioactive noble gas $^{222}$Rn, which can be dissolved in water, is an important background source for JUNO. In this paper, based on the water system of JUNO prototype, two kinds of high sensitivity radon detectors have been proposed and developed. The sensitivity of Si-PIN Rn detector, which uses a Si-PIN photodiode to detect the $α$ from $^{214}$Po decay, is $\sim$9.0~mBq/m$^3$. The sensitivity of LS Rn detector, which uses liquid scintillator to detect the coincident signals of $β$ from $^{214}$Bi decay and $α$ from $^{214}$Po decay, is $\sim$64.0~mBq/m$^3$. Both of the two kinds of Rn detector have the potential to be developed as an online Rn concentration monitoring equipment for JUNO veto detector.

physics.ins-det

Using Mineral Oil to Improve the Performance of Multi-Crystal Detector for Dark Matter Searching

The inorganic crystals have been widely used for dark matter direct searching for many decades. However, limited by the crystal growth technique, a lot of small crystals have to be used together for large target mass, which results in a degradation of light collection efficiency. An experiment was built up to study the degradation, and the method of soaking crystals into mineral oil to improve the efficiency as well as reduce the interface effect were proposed and validated. Good data and MC agreements were achieved in the experiment.

physics.ins-det

Improved Measurement of the Reactor Antineutrino Flux and Spectrum at Daya Bay

A new measurement of the reactor antineutrino flux and energy spectrum by the Daya Bay reactor neutrino experiment is reported. The antineutrinos were generated by six 2.9~GW$_{\mathrm{th}}$ nuclear reactors and detected by eight antineutrino detectors deployed in two near (560~m and 600~m flux-weighted baselines) and one far (1640~m flux-weighted baseline) underground experimental halls. With 621 days of data, more than 1.2 million inverse beta decay (IBD) candidates were detected. The IBD yield in the eight detectors was measured, and the ratio of measured to predicted flux was found to be $0.946\pm0.020$ ($0.992\pm0.021$) for the Huber+Mueller (ILL+Vogel) model. A 2.9~$σ$ deviation was found in the measured IBD positron energy spectrum compared to the predictions. In particular, an excess of events in the region of 4-6~MeV was found in the measured spectrum, with a local significance of 4.4~$σ$. A reactor antineutrino spectrum weighted by the IBD cross section is extracted for model-independent predictions.

hep-ex

Limits on Active to Sterile Neutrino Oscillations from Disappearance Searches in the MINOS, Daya Bay, and Bugey-3 Experiments

Searches for a light sterile neutrino have been performed independently by the MINOS and the Daya Bay experiments using the muon (anti)neutrino and electron antineutrino disappearance channels, respectively. In this Letter, results from both experiments are combined with those from the Bugey-3 reactor neutrino experiment to constrain oscillations into light sterile neutrinos. The three experiments are sensitive to complementary regions of parameter space, enabling the combined analysis to probe regions allowed by the LSND and MiniBooNE experiments in a minimally extended four-neutrino flavor framework. Stringent limits on $\sin^2 2θ_{μe}$ are set over 6 orders of magnitude in the sterile mass-squared splitting $Δm^2_{41}$. The sterile-neutrino mixing phase space allowed by the LSND and MiniBooNE experiments is excluded for $Δm^2_{41} < 0.8$ eV$^2$ at 95% CL$_s$.

hep-ex

Measurement of electron antineutrino oscillation based on 1230 days of operation of the Daya Bay experiment

A measurement of electron antineutrino oscillation by the Daya Bay Reactor Neutrino Experiment is described in detail. Six 2.9-GW$_{\rm th}$ nuclear power reactors of the Daya Bay and Ling Ao nuclear power facilities served as intense sources of $\overlineν_{e}$'s. Comparison of the $\overlineν_{e}$ rate and energy spectrum measured by antineutrino detectors far from the nuclear reactors ($\sim$1500-1950 m) relative to detectors near the reactors ($\sim$350-600 m) allowed a precise measurement of $\overlineν_{e}$ disappearance. More than 2.5 million $\overlineν_{e}$ inverse beta decay interactions were observed, based on the combination of 217 days of operation of six antineutrino detectors (Dec. 2011--Jul. 2012) with a subsequent 1013 days using the complete configuration of eight detectors (Oct. 2012--Jul. 2015). The $\overlineν_{e}$ rate observed at the far detectors relative to the near detectors showed a significant deficit, $R=0.949 \pm 0.002(\mathrm{stat.}) \pm 0.002(\mathrm{syst.})$. The energy dependence of $\overlineν_{e}$ disappearance showed the distinct variation predicted by neutrino oscillation. Analysis using an approximation for the three-flavor oscillation probability yielded the flavor-mixing angle $\sin^22θ_{13}=0.0841 \pm 0.0027(\mathrm{stat.}) \pm 0.0019(\mathrm{syst.})$ and the effective neutrino mass-squared difference of $\left|Δm^2_{\mathrm{ee}}\right|=(2.50 \pm 0.06(\mathrm{stat.}) \pm 0.06(\mathrm{syst.})) \times 10^{-3}\ {\rm eV}^2$. Analysis using the exact three-flavor probability found $Δm^2_{32}=(2.45 \pm 0.06(\mathrm{stat.}) \pm 0.06(\mathrm{syst.})) \times 10^{-3}\ {\rm eV}^2$ assuming the normal neutrino mass hierarchy and $Δm^2_{32}=(-2.56 \pm 0.06(\mathrm{stat.}) \pm 0.06(\mathrm{syst.})) \times 10^{-3}\ {\rm eV}^2$ for the inverted hierarchy.

hep-ex

Improved Search for a Light Sterile Neutrino with the Full Configuration of the Daya Bay Experiment

This Letter reports an improved search for light sterile neutrino mixing in the electron antineutrino disappearance channel with the full configuration of the Daya Bay Reactor Neutrino Experiment. With an additional 404 days of data collected in eight antineutrino detectors, this search benefits from 3.6 times the statistics available to the previous publication, as well as from improvements in energy calibration and background reduction. A relative comparison of the rate and energy spectrum of reactor antineutrinos in the three experimental halls yields no evidence of sterile neutrino mixing in the $2\times10^{-4} \lesssim |Δm^{2}_{41}| \lesssim 0.3$ eV$^{2}$ mass range. The resulting limits on $\sin^{2}2θ_{14}$ are improved by approximately a factor of 2 over previous results and constitute the most stringent constraints to date in the $|Δm^{2}_{41}| \lesssim 0.2$ eV$^{2}$ region.

hep-ex

Study of the wave packet treatment of neutrino oscillation at Daya Bay

The disappearance of reactor $\barν_e$ observed by the Daya Bay experiment is examined in the framework of a model in which the neutrino is described by a wave packet with a relative intrinsic momentum dispersion $σ_\text{rel}$. Three pairs of nuclear reactors and eight antineutrino detectors, each with good energy resolution, distributed among three experimental halls, supply a high-statistics sample of $\barν_e$ acquired at nine different baselines. This provides a unique platform to test the effects which arise from the wave packet treatment of neutrino oscillation. The modified survival probability formula was used to fit Daya Bay data, providing the first experimental limits: $2.38 \cdot 10^{-17} < σ_{\rm rel} < 0.23$. Treating the dimensions of the reactor cores and detectors as constraints, the limits are improved: $10^{-14} \lesssim σ_{\rm rel} < 0.23$, and an upper limit of $σ_{\rm rel} <0.20$ is obtained. All limits correspond to a 95\% C.L. Furthermore, the effect due to the wave packet nature of neutrino oscillation is found to be insignificant for reactor antineutrinos detected by the Daya Bay experiment thus ensuring an unbiased measurement of the oscillation parameters $\sin^22θ_{13}$ and $Δm^2_{32}$ within the plane wave model.

hep-ex

New measurement of $θ_{13}$ via neutron capture on hydrogen at Daya Bay

This article reports an improved independent measurement of neutrino mixing angle $θ_{13}$ at the Daya Bay Reactor Neutrino Experiment. Electron antineutrinos were identified by inverse $β$-decays with the emitted neutron captured by hydrogen, yielding a data-set with principally distinct uncertainties from that with neutrons captured by gadolinium. With the final two of eight antineutrino detectors installed, this study used 621 days of data including the previously reported 217-day data set with six detectors. The dominant statistical uncertainty was reduced by 49%. Intensive studies of the cosmogenic muon-induced $^9$Li and fast neutron backgrounds and the neutron-capture energy selection efficiency, resulted in a reduction of the systematic uncertainty by 26%. The deficit in the detected number of antineutrinos at the far detectors relative to the expected number based on the near detectors yielded $\sin^22θ_{13} = 0.071 \pm 0.011$ in the three-neutrino-oscillation framework. The combination of this result with the gadolinium-capture result is also reported.

hep-ex

The Detector System of The Daya Bay Reactor Neutrino Experiment

The Daya Bay experiment was the first to report simultaneous measurements of reactor antineutrinos at multiple baselines leading to the discovery of $\barν_e$ oscillations over km-baselines. Subsequent data has provided the world's most precise measurement of $\rm{sin}^22θ_{13}$ and the effective mass splitting $Δm_{ee}^2$. The experiment is located in Daya Bay, China where the cluster of six nuclear reactors is among the world's most prolific sources of electron antineutrinos. Multiple antineutrino detectors are deployed in three underground water pools at different distances from the reactor cores to search for deviations in the antineutrino rate and energy spectrum due to neutrino mixing. Instrumented with photomultiplier tubes (PMTs), the water pools serve as shielding against natural radioactivity from the surrounding rock and provide efficient muon tagging. Arrays of resistive plate chambers over the top of each pool provide additional muon detection. The antineutrino detectors were specifically designed for measurements of the antineutrino flux with minimal systematic uncertainty. Relative detector efficiencies between the near and far detectors are known to better than 0.2%. With the unblinding of the final two detectors' baselines and target masses, a complete description and comparison of the eight antineutrino detectors can now be presented. This paper describes the Daya Bay detector systems, consisting of eight antineutrino detectors in three instrumented water pools in three underground halls, and their operation through the first year of eight detector data-taking.

physics.ins-det

A new measurement of antineutrino oscillation with the full detector configuration at Daya Bay

We report a new measurement of electron antineutrino disappearance using the fully-constructed Daya Bay Reactor Neutrino Experiment. The final two of eight antineutrino detectors were installed in the summer of 2012. Including the 404 days of data collected from October 2012 to November 2013 resulted in a total exposure of 6.9$\times$10$^5$ GW$_{\rm th}$-ton-days, a 3.6 times increase over our previous results. Improvements in energy calibration limited variations between detectors to 0.2%. Removal of six $^{241}$Am-$^{13}$C radioactive calibration sources reduced the background by a factor of two for the detectors in the experimental hall furthest from the reactors. Direct prediction of the antineutrino signal in the far detectors based on the measurements in the near detectors explicitly minimized the dependence of the measurement on models of reactor antineutrino emission. The uncertainties in our estimates of $\sin^{2}2θ_{13}$ and $|Δm^2_{ee}|$ were halved as a result of these improvements. Analysis of the relative antineutrino rates and energy spectra between detectors gave $\sin^{2}2θ_{13} = 0.084\pm0.005$ and $|Δm^{2}_{ee}|= (2.42\pm0.11) \times 10^{-3}$ eV$^2$ in the three-neutrino framework.

hep-ex

Measurement of the Reactor Antineutrino Flux and Spectrum at Daya Bay

This Letter reports a measurement of the flux and energy spectrum of electron antineutrinos from six 2.9~GW$_{th}$ nuclear reactors with six detectors deployed in two near (effective baselines 512~m and 561~m) and one far (1,579~m) underground experimental halls in the Daya Bay experiment. Using 217 days of data, 296,721 and 41,589 inverse beta decay (IBD) candidates were detected in the near and far halls, respectively. The measured IBD yield is (1.55 $\pm$ 0.04) $\times$ 10$^{-18}$~cm$^2$/GW/day or (5.92 $\pm$ 0.14) $\times$ 10$^{-43}$~cm$^2$/fission. This flux measurement is consistent with previous short-baseline reactor antineutrino experiments and is $0.946\pm0.022$ ($0.991\pm0.023$) relative to the flux predicted with the Huber+Mueller (ILL+Vogel) fissile antineutrino model. The measured IBD positron energy spectrum deviates from both spectral predictions by more than 2$σ$ over the full energy range with a local significance of up to $\sim$4$σ$ between 4-6 MeV. A reactor antineutrino spectrum of IBD reactions is extracted from the measured positron energy spectrum for model-independent predictions.

hep-ex

First Results from the DarkSide-50 Dark Matter Experiment at Laboratori Nazionali del Gran Sasso

We report the first results of DarkSide-50, a direct search for dark matter operating in the underground Laboratori Nazionali del Gran Sasso (LNGS) and searching for the rare nuclear recoils possibly induced by weakly interacting massive particles (WIMPs). The dark matter detector is a Liquid Argon Time Projection Chamber with a (46.4+-0.7) kg active mass, operated inside a 30 t organic liquid scintillator neutron veto, which is in turn installed at the center of a 1 kt water Cherenkov veto for the residual flux of cosmic rays. We report here the null results of a dark matter search for a (1422+-67) kg d exposure with an atmospheric argon fill. This is the most sensitive dark matter search performed with an argon target, corresponding to a 90% CL upper limit on the WIMP-nucleon spin-independent cross section of 6.1x10^-44 cm^2 for a WIMP mass of 100 GeV/c^2.

astro-ph.CO

The Electronics and Data Acquisition System of the DarkSide Dark Matter Search

It is generally inferred from astronomical measurements that Dark Matter (DM) comprises approximately 27\% of the energy-density of the universe. If DM is a subatomic particle, a possible candidate is a Weakly Interacting Massive Particle (WIMP), and the DarkSide-50 (DS) experiment is a direct search for evidence of WIMP-nuclear collisions. DS is located underground at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy, and consists of three active, embedded components; an outer water veto (CTF), a liquid scintillator veto (LSV), and a liquid argon (LAr) time projection chamber (TPC). This paper describes the data acquisition and electronic systems of the DS detectors, designed to detect the residual ionization from such collisions.

astro-ph.IM