SearcharxivSearch

arXiv subjects

Mani Tripathi

Publications and source records attributed to Mani Tripathi.

16 recordsLinked to original sources

Gas Electroluminescence in a Dual Phase Xenon-Doped Argon Detector

Noble element detectors using argon or xenon as the detection medium are widely used in the searches for rare neutrino and dark matter interactions. Xenon doping in liquid argon can preserve attractive properties of an argon target while enhancing the detectable signals with properties of xenon. In this work, we deployed a dual-phase liquid argon detector with up to 4% xenon doping in the liquid and studied its gas electroluminescence properties as a function of xenon concentration. At $\sim$2% xenon doping in liquid argon, we measured $\sim$34 ppm of xenon in the gas and observed $\sim$2.5 times larger electroluminescence signals in the detector than those in pure argon. By analyzing signals recorded by photosensors of different wavelength sensitivities, we confirm that the argon gas electroluminescence process is strongly affected by the addition of xenon. We propose an analytical model to describe the underlying energy transfer mechanism in argon-xenon gas mixtures. Lastly, the implications of this measurement for low energy ionization signal detection will be discussed.

physics.ins-det

Investigating Resource-efficient Neutron/Gamma Classification ML Models Targeting eFPGAs

There has been considerable interest and resulting progress in implementing machine learning (ML) models in hardware over the last several years from the particle and nuclear physics communities. A big driver has been the release of the Python package, hls4ml, which has enabled porting models specified and trained using Python ML libraries to register transfer level (RTL) code. So far, the primary end targets have been commercial FPGAs or synthesized custom blocks on ASICs. However, recent developments in open-source embedded FPGA (eFPGA) frameworks now provide an alternate, more flexible pathway for implementing ML models in hardware. These customized eFPGA fabrics can be integrated as part of an overall chip design. In general, the decision between a fully custom, eFPGA, or commercial FPGA ML implementation will depend on the details of the end-use application. In this work, we explored the parameter space for eFPGA implementations of fully-connected neural network (fcNN) and boosted decision tree (BDT) models using the task of neutron/gamma classification with a specific focus on resource efficiency. We used data collected using an AmBe sealed source incident on Stilbene, which was optically coupled to an OnSemi J-series SiPM to generate training and test data for this study. We investigated relevant input features and the effects of bit-resolution and sampling rate as well as trade-offs in hyperparameters for both ML architectures while tracking total resource usage. The performance metric used to track model performance was the calculated neutron efficiency at a gamma leakage of 10$^{-3}$. The results of the study will be used to aid the specification of an eFPGA fabric, which will be integrated as part of a test chip.

cs.LG

Search for the Migdal effect in liquid xenon with keV-level nuclear recoils

The Migdal effect predicts that a nuclear recoil interaction can be accompanied by atomic ionization, allowing many dark matter direct detection experiments to gain sensitivity to sub-GeV masses. We report the first direct search for the Migdal effect for M- and L-shell electrons in liquid xenon using 7.0$\pm$1.6 keV nuclear recoils produced by tagged neutron scatters. Despite an observed background rate lower than that of expected signals in the region of interest, we do not observe a signal consistent with predictions. We discuss possible explanations, including inaccurate predictions for either the Migdal rate or the signal response in liquid xenon. We comment on the implications for direct dark-matter searches and future Migdal characterization efforts.

hep-ex

Calibrating the scintillation and ionization responses of xenon recoils for high-energy dark matter searches

Liquid xenon-based direct detection dark matter experiments have recently expanded their searches to include high-energy nuclear recoil events as motivated by effective field theory dark matter and inelastic dark matter interaction models, but few xenon recoil calibrations above 100 keV are currently available. In this work, we measured the scintillation and ionization yields of xenon recoils up to 426 keV. The experiment uses 14.1 MeV neutrons to scatter off xenon in a compact liquid xenon time projection chamber and produce quasi-monoenergetic xenon recoils between 39 keV and 426 keV. We report the xenon recoil responses and their electric field-dependence for recoil energies up to 306 keV; due to the low event statistics and the relatively mild field dependence, the yield values at higher energies are reported as the average of xenon responses for electric fields between 0.2-2.0 kV/cm. This result will enable xenon-based dark matter experiments to significantly increase their high energy dark matter sensitivities by including energy regions that were previously inaccessible due to lack of calibrations.

physics.ins-det

Thermodynamic Stability of Xenon-Doped Liquid Argon Detectors

Liquid argon detectors are employed in a wide variety of nuclear and particle physics experiments. The addition of small quantities of xenon to argon modifies its scintillation, ionization, and electroluminescence properties and can improve its performance as a detection medium. However, a liquid argon-xenon mixture can develop instabilities, especially in systems that require phase transitions or that utilize high xenon concentrations. In this work, we discuss the causes for such instabilities and describe a small (liter-scale) apparatus with a unique cryogenic circuit specifically designed to handle argon-xenon mixtures. The system is capable of condensing argon gas mixed with O(1%) xenon by volume and maintains a stable liquid mixture near the xenon saturation limit while actively circulating it in the gas phase. We also demonstrate control over instabilities that develop when the detector condition is allowed to deviate from optimized settings. This progress enables future liquid argon detectors to benefit from the effects of high concentrations of xenon doping, such as more efficient detection of low-energy ionization signals. This work also develops tools to study and mitigate instabilities in large argon detectors that use low concentration xenon doping.

physics.ins-det

Measurement of the ionization yield from nuclear recoils in liquid xenon between 0.3 -- 6 keV with single-ionization-electron sensitivity

Dual-phase xenon TPC detectors are a highly scalable and widely used technology to search for low-energy nuclear recoil signals from WIMP dark matter or coherent nuclear scattering of $\sim$MeV neutrinos. Such experiments expect to measure O(keV) ionization or scintillation signals from such sources. However, at $\sim1\,$keV and below, the signal calibrations in liquid xenon carry large uncertainties that directly impact the assumed sensitivity of existing and future experiments. In this work, we report a new measurement of the ionization yield of nuclear recoil signals in liquid xenon down to 0.3$\,$keV$\,\,$-- the lowest energy calibration reported to date -- at which energy the average event produces just 1.1~ionized~electrons. Between 2 and 6$\,$keV, our measurements agree with existing measurements, but significantly improve the precision. At lower energies, we observe a decreasing trend that deviates from simple extrapolations of existing data. We also study the dependence of ionization yield on the applied drift field in liquid xenon between 220V/cm and 6240V/cm, allowing these measurements to apply to a broad range of current and proposed experiments with different operating parameters.

physics.ins-det

Electron extraction efficiency study for dual-phase xenon dark matter experiments

Dual-phase xenon detectors are widely used in dark matter direct detection experiments, and have demonstrated the highest sensitivities to a variety of dark matter interactions. However, a key component of the dual-phase detector technology--the efficiency of charge extraction from liquid xenon into gas--has not been well characterized. In this paper, we report a new measurement of the electron extraction efficiency (EEE) in a small xenon detector using two mono-energetic decay features of $^{37}$Ar. By achieving stable operation at very high voltages, we measured the EEE values at the highest extraction electric field strength reported to date. For the first time, an apparent saturation of the EEE is observed over a large range of electric field; between 7.5 kV/cm and 10.4 kV/cm extraction field in the liquid xenon the EEE stays stable at the level of 1%(kV/cm)$^{-1}$. In the context of electron transport models developed for xenon, we discuss how the observed saturation may help calibrate this relative EEE measurement to the absolute EEE values. In addition, we present the implications of this result not only to current and future xenon-based dark matter searches, but also to xenon-based searches for coherent elastic neutrino-nucleus scatters.

physics.ins-det

Pressure Dependence of Carbon Foam Bonding Strength using Reactive Film

Reactive bonding film is a relatively new method of fusing materials with the potential to meet needs of particle tracker mechanics under development due to its resulting tensile strength, thermal conductivity, radiation tolerance, and low mass. Employing a new apparatus to vary pressure applied to samples during bonding, we find improved ultimate tensile strengths compared with previous results.

physics.ins-det

On the Evaluation of Silicon Photomultipliers for Use as Photosensors in Liquid Xenon Detectors

Silicon photomultipliers (SiPMs) are potential solid-state alternatives to traditional photomultiplier tubes (PMTs) for single-photon detection. In this paper, we report on evaluating SensL MicroFC-10035-SMT SiPMs for their suitability as PMT replacements. The devices were successfully operated in a liquid-xenon detector, which demonstrates that SiPMs can be used in noble element time projection chambers as photosensors. The devices were also cooled down to 170 K to observe dark count dependence on temperature. No dependencies on the direction of an applied 3.2 kV/cm electric field were observed with respect to dark-count rate, gain, or photon detection efficiency.

physics.ins-det

Reactive Bonding Film for Bonding Carbon Foam Through Metal Extrusion

Future tracking detectors, such as those under development for the High Luminosity LHC, will require mechanical structures employing novel materials to reduce mass while providing excellent strength, thermal conductivity, and radiation tolerance. Adhesion methods for such materials are under study at present. This paper demonstrates the use of reactive bonding film as an adhesion method for bonding carbon foam.

physics.ins-det

Thermal and Tensile Strength Testing of Thermally-Conductive Adhesives and Carbon Foam

Future collider detectors, including silicon tracking detectors planned for the High Luminosity LHC, will require components and mechanical structures providing unprecedented strength-to-mass ratios, thermal conductivity, and radiation tolerance. This paper studies carbon foam used in conjunction with thermally conductive epoxy and thermally conductive tape for such applications. Thermal performance and tensile strength measurements of aluminum-carbon foam-adhesive stacks are reported, along with initial radiation damage test results.

physics.ins-det

Position Reconstruction of Bubble Formation in Liquid Nitrogen using Piezoelectric Sensors

Cryogenic liquids, particularly liquid xenon and argon, are of interest as detector media for experiments in nuclear and particle physics. Here we present a new detector diagnostic technique using piezoelectric sensors to detect bubbling of the liquid. Bubbling can indicate locations of excess heat dissipation e.g., in immersed electronics. They can also interfere with normal event evolution by scattering of light or by interrupting the drift of ionization charge. In our test apparatus, four sensors are placed in the vacuum space of a double-walled dewar of liquid nitrogen and used to detect and locate a source of bubbling inside the liquid volume. Utilizing the differences in transmitted frequencies through the different media present in the experiment, we find that sound traveling in a direct path from the source to the sensor can be isolated with appropriate filtering. The location of the source is then reconstructed using the time difference of arrivals (TDOA) information. The reconstruction algorithm is shown to have a 95.8% convergence rate and reconstructed positions are self-consistent to an average +/-0.5cm around the mean in x, y, and z. Systematic effects are observed to cause errors in reconstruction when bubbles occur very close to the surfaces of the liquid volume.

physics.ins-det

A Global Analysis of Light and Charge Yields in Liquid Xenon

We present an updated model of light and charge yields from nuclear recoils in liquid xenon with a simultaneously constrained parameter set. A global analysis is performed using measurements of electron and photon yields compiled from all available historical data, as well as measurements of the ratio of the two. These data sweep over energies from 1 - 300 keV and external applied electric fields from 0 - 4060 V/cm. The model is constrained by constructing global cost functions and using a gradient descent minimizer, a simulated annealing algorithm, and a Markov Chain Monte Carlo approach to optimize and find confidence intervals on all free parameters in the model. This analysis contrasts with previous work in that we do not unnecessarily exclude data sets nor impose artificially conservative assumptions, do not use spline functions, and reduce the number of parameters used in NEST v0.98. We report our results and the calculated best-fit charge and light yields. These quantities are crucial to understanding the response of liquid xenon detectors in the energy regime important for rare event searches such as the direct detection of dark matter particles.

astro-ph.IM

Searching for Dark Matter at Hadron Colliders

Theoretical and experimental techniques employed in dedicated searches for dark matter at hadron colliders are reviewed. Bounds from the 7 and 8 TeV proton-proton collisions at the LHC on dark matter interactions have been collected and the results interpreted. We review the current status of the Effective Field Theory picture of dark matter interactions with the Standard Model. Currently, LHC experiments have stronger bounds on operators leading to spin-dependent scattering than direct detection experiments, while direct detection probes are more constraining for spin-independent scattering for WIMP masses above a few GeV.

hep-ph

Modeling Pulse Characteristics in Xenon with NEST

A comprehensive model for describing the characteristics of pulsed signals, generated by particle interactions in xenon detectors, is presented. An emphasis is laid on two-phase time projection chambers, but the models presented are also applicable to single phase detectors. In order to simulate the pulse shape due to primary scintillation light, the effects of the ratio of singlet and triplet dimer state populations, as well as their corresponding decay times, and the recombination time are incorporated into the model. In a two phase time projection chamber, when simulating the pulse caused by electroluminescence light, the ionization electron mean free path in gas, the drift velocity, singlet and triplet decay times, diffusion constants, and the electron trapping time, have been implemented. This modeling has been incorporated into a complete software package, which realistically simulates the expected pulse shapes for these types of detectors.

physics.ins-det

Enhancement of NEST Capabilities for Simulating Low-Energy Recoils in Liquid Xenon

The Noble Element Simulation Technique (NEST) is an exhaustive collection of models explaining both the scintillation light and ionization yields of noble elements as a function of particle type (nuclear recoil, electron recoil, alphas), electric field, and incident energy or energy loss dE/dx. It is packaged as C++ code for Geant4 that implements said models, overriding the default model which does not account for certain complexities, such as the reduction in yields for nuclear recoils (NR) compared to electron recoils (ER). We present here improvements to the existing NEST models and updates to the code which make the package even more realistic and turn it into a more full-fledged Monte Carlo simulation. All available liquid xenon data on NR and ER to date have been taken into consideration in arriving at the current models. Furthermore, NEST addresses the question of the magnitude of the light and charge yields of nuclear recoils, including their electric field dependence, thereby shedding light on the possibility of detection or exclusion of a low-mass dark matter WIMP by liquid xenon detectors.

physics.ins-det