Searcharxiv⌕ Search

arXiv subjects

Marcin S. Mrozowski

Publications and source records attributed to Marcin S. Mrozowski.

3 recordsLinked to original sources

High-Resolution Atomic Magnetometer-Based Imaging of Integrated Circuits and Batteries

Optically pumped magnetometers (OPMs) have emerged as a powerful technique for high-resolution magnetic field imaging. However, achieving sub-millimeter spatial resolution at sub-picotesla sensitivities ($\mathrm{< 1\,pT/\sqrt{Hz}}$) remains challenging, particularly under finite-field conditions. We present a high-resolution magnetic imaging system based on a free-induction-decay (FID) OPM integrated with a two-axis scanning micromirror for automated beam steering. The double-pass optical configuration allows millimeter-scale devices under test (DUTs) to be positioned directly behind the vapor cell. This enables a standoff distance of 2.7 mm between the magnetic source and the atomic vapor, improving practical imaging resolution by increasing the amplitude of near-field magnetic signals sampled within the sensitive volume. Spatial resolution is experimentally demonstrated by imaging a custom printed circuit board (PCB) containing antiparallel copper tracks spaced 2 mm apart, with measured field maps in close agreement with Biot-Savart predictions. The OPM achieves an optimal field sensitivity of $\mathrm{0.5\,pT/\sqrt{Hz}}$, demonstrating the system's capability for high-precision magnetic field measurements. The imaging system is further validated by resolving polarity-dependent asymmetries in a bridge rectifier integrated circuit (IC) and tracking current dynamics in a ceramic battery in situ. These results highlight the potential of OPM-based systems for noninvasive diagnostics of electronic circuits and batteries.

physics.atom-ph↗

A triaxial vectorization technique for a single-beam zero-field atomic magnetometer to suppress cross-axis projection error

Zero-field optically pumped magnetometers (OPMs) have emerged as an important technology for biomagnetism due to their ulta-sensitive performance, contained within a non-cryogenic small-scale sensor-head. The compactness of such OPMs is often achieved through simplified detection schemes, which typically provide only single-axis magnetic field information. However, multi-axis static magnetic fields on non-measurement axes cause a systematic error that manifests as amplitude and phase errors across the measurement axis. Here we present a triaxial operational technique for a compact zero-field OPM which suppresses multi-axis systematic errors through simultaneous measurement and closed-loop active control of the static magnetic fields across all axes. The demonstrated technique requires magnetic modulation across two axes while providing static field information for all three axes. We demonstrate this technique on a rubidium laboratory-based zero-field magnetometer, achieving a bandwidth of 380 Hz with sensitivities of $<25$ fT/$\sqrt{\rm{Hz}}$ across both transverse axes and $65$ fT/$\sqrt{\rm{Hz}}$ along the beam axis. Using the proposed triaxial technique, we demonstrate precise tracking of a 2 Hz triaxial vector test signal and suppression of systematic cross-axis projection errors over an extended period, $\simeq20$~min.

physics.atom-ph↗

Optical pumping enhancement of a free-induction-decay magnetometer

Spin preparation prior to a free-induction-decay (FID) measurement can be adversely affected by transverse bias fields, particularly in the geophysical field range. A strategy that enhances the spin polarization accumulated before readout is demonstrated, by synchronizing optical pumping with a magnetic field pulse that supersedes any transverse fields by over two order of magnitude. The pulsed magnetic field is generated along the optical pumping axis using a compact electromagnetic coil pair encompassing a micro-electromechanical systems (MEMS) vapor cell. The coils also resistively heat the cesium (Cs) vapor to the optimal atomic density without spurious magnetic field contributions as they are rapidly demagnetized to approximately zero field during spin readout. The demagnetization process is analyzed electronically, and directly with a FID measurement, to confirm that the residual magnetic field is minimal during detection. The sensitivity performance of this technique is compared to existing optical pumping modalities across a wide magnetic field range. A noise floor sensitivity of $238\,\mathrm{fT/\surd{Hz}}$ was achieved in a field of approximately $\mathrm{50\,μ{T}}$, in close agreement with the Cramér-Rao lower bound (CRLB) predicted noise density of $258\,\mathrm{fT/\surd{Hz}}$.

physics.atom-ph↗