SearcharxivSearch

arXiv · 2508.20834

High-Resolution Atomic Magnetometer-Based Imaging of Integrated Circuits and Batteries

Abstract

Optically pumped magnetometers (OPMs) have emerged as a powerful technique for high-resolution magnetic field imaging. However, achieving sub-millimeter spatial resolution at sub-picotesla sensitivities ($\mathrm{< 1\,pT/\sqrt{Hz}}$) remains challenging, particularly under finite-field conditions. We present a high-resolution magnetic imaging system based on a free-induction-decay (FID) OPM integrated with a two-axis scanning micromirror for automated beam steering. The double-pass optical configuration allows millimeter-scale devices under test (DUTs) to be positioned directly behind the vapor cell. This enables a standoff distance of 2.7 mm between the magnetic source and the atomic vapor, improving practical imaging resolution by increasing the amplitude of near-field magnetic signals sampled within the sensitive volume. Spatial resolution is experimentally demonstrated by imaging a custom printed circuit board (PCB) containing antiparallel copper tracks spaced 2 mm apart, with measured field maps in close agreement with Biot-Savart predictions. The OPM achieves an optimal field sensitivity of $\mathrm{0.5\,pT/\sqrt{Hz}}$, demonstrating the system's capability for high-precision magnetic field measurements. The imaging system is further validated by resolving polarity-dependent asymmetries in a bridge rectifier integrated circuit (IC) and tracking current dynamics in a ceramic battery in situ. These results highlight the potential of OPM-based systems for noninvasive diagnostics of electronic circuits and batteries.

Explore related subjects

Keep this discovery

BibTeXRIS

Dominic Hunter, Marcin S. Mrozowski, Stuart J. Ingleby, Timothy S. Read, Allan P. McWilliam, James P. McGilligan, Ralf Bauer, Peter D. D. Schwindt, Paul F. Griffin, Erling Riis. 2025-08-28. High-Resolution Atomic Magnetometer-Based Imaging of Integrated Circuits and Batteries. https://doi.org/10.1109/tim.2026.3664381

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Delay-engineered dynamical phases in a programmable non-Markovian spin oscillator

Non-Markovian dynamics offer a new route towards engineering non-equilibrium matter, where memory and feedback act as programmable resources for controlling order in time. Here we report the realization of a non-Markovian spin oscillator in a hot vapour $^{129}$Xe-Cs co-magnetometer with programmable feedback delay and gain. By tuning these parameters, we observe a hierarchy of dynamical phases, including time-crystalline response, nonlinear bifurcations, and frequency-comb formation. The measured spectra and phase boundaries are captured by linear stability analysis of delayed Bloch equations, revealing these phenomena as different manifestations of the same memory-induced instability structure. These results establish time-delayed feedback as a powerful strategy for controlling non-equilibrium phases, enabling quantum sensing, frequency referencing, and synchronization within a single spin-based platform.

physics.atom-ph

Non-stick vacuum wall collisions with a laser-coolable molecule

Molecular species that are suitable for direct laser cooling are typically considered lost or destroyed if they collide with an ambient temperature vacuum wall. Here, we study surface collisions with aluminum monofluoride (AlF), a laser-coolable molecule that survives this process with unusually high probability. We detect the outgoing AlF molecules from a single wall collision via Doppler-sensitive laser-induced fluorescence spectroscopy, using incoming supersonic (pulsed) and thermochemical (continuous) molecular beams. The angular, velocity and rovibrational level distributions of the outgoing molecules show near-complete thermalisation to the wall in a single collision event. We determine an upper limit to the surface residence time of about 5$~\mu$s, and by monitoring the decay in density of pulses of molecules loaded into a small storage volume, we deduce the surface sticking probability for different materials. For a siloxane-coated metallic surface, the sticking probability of AlF is about 0.015, allowing us to accumulate molecules from the thermochemical source into an ambient temperature storage vessel at densities near $10^{8}~$cm$^{-3}$. This provides a route to compact, portable traps for neutral molecules.

physics.atom-ph

Kinetic modeling of molecular beam formation in a cryogenic buffer-gas cell

Cryogenic buffer-gas cells are widely used to produce cold molecular beams, but the microscopic dynamics governing beam formation remain challenging to model. Here we present fully kinetic simulations of a cryogenic buffer-gas cell using the Direct Simulation Monte Carlo method implemented in the PICLas framework, treating the buffer gas and ablated molecules within a single unified model. We capture characteristic features of cryogenic buffer-gas sources, including plume cooling, directed transport toward the aperture, and the formation of a slow molecular beam, while also resolving energy transfer from the hot ablation plume to the helium buffer gas that is inaccessible to existing approaches relying on the background-gas approximation. Our results demonstrate that fully kinetic simulations can provide detailed insights into buffer-gas cell dynamics and open a route toward a systematic optimization of such sources.

physics.atom-ph