Searcharxiv⌕ Search

arXiv subjects

Marco Costa

Publications and source records attributed to Marco Costa.

26 records · Page 2Linked to original sources

The last Complex WIMPs standing

We continue the study of weakly interacting massive particles (WIMP) started in [arXiv:2107.09688], focusing on a single complex electroweak $n$-plet with non-zero hypercharge added to the Standard Model. The minimal splitting between the Dark Matter and its electroweak neutral partner required to circumvent direct detection constraints allows only multiplets with hypercharge smaller or equal to 1. We compute for the first time all the calculable WIMP masses up to the largest multiplet allowed by perturbative unitarity. For the minimal allowed splitting, most of these multiplets can be fully probed at future large-exposure direct detection experiments, with the notable exception of the doublet with hypercharge 1/2. We show how a future muon collider can fully explore the parameter space of the complex doublet combining missing mass, displaced track and long-lived track searches. In the same spirit, we study how a future muon collider can probe the parameter space of complex WIMPs in regions where the direct detection cross section drops below the neutrino floor. Finally, we comment on how precision observables can provide additional constraints on complex WIMPs.

hep-ph↗

Optimization of the Gain Layer Design of Ultra-Fast Silicon Detectors

In the past few years, the need of measuring accurately the spatial and temporal coordinates of the particles generated in high-energy physics experiments has spurred a strong R\&D in the field of silicon sensors. Within these research activities, the so-called Ultra-Fast Silicon Detectors (UFSDs), silicon sensors optimized for timing based on the Low-Gain Avalanche Diode (LGAD) design, have been proposed and adopted by the CMS and ATLAS collaborations for their respective timing layers. The defining feature of the Ultra-Fast Silicon Detectors (UFSDs) is the internal multiplication mechanism, determined by the gain layer design. In this paper, the performances of several types of gain layers, measured with a telescope instrumented with a $^{90}$Sr $β$-source, are reported and compared. The measured sensors are produced by Fondazione Bruno Kessler (FBK) and Hamamatsu Photonics (HPK). The sensor yielding the best performance, both when new and irradiated, is an FBK 45\mum-thick sensor with a carbonated deep gain implant, where the carbon and the boron implants are annealed concurrently with a low thermal load. This sensor is able to achieve a time resolution of 40~ps up to a radiation fluence of~\fluence{2.5}{15}, delivering at least 5~fC of charge.

physics.ins-det↗

Closing the window on WIMP Dark Matter

We study scenarios where Dark Matter is a weakly interacting particle (WIMP) embedded in an ElectroWeak multiplet. In particular, we consider real SU(2) representations with zero hypercharge, that automatically avoid direct detection constraints from tree-level Z-exchange. We compute for the first time all the calculable thermal masses for scalar and fermionic WIMPs, including Sommerfeld enhancement and bound states formation at leading order in gauge boson exchange and emission. WIMP masses of few hundred TeV are shown to be compatible both with s-wave unitarity of the annihilation cross-section, and perturbativity. We also provide theory uncertainties on the masses for all multiplets, which are shown to be significant for large SU(2) multiplets. We then outline a strategy to probe these scenarios at future experiments. Electroweak 3-plets and 5-plets have masses up to about 16 TeV and can efficiently be probed at a high energy muon collider. We study various experimental signatures, such as single and double gauge boson emission with missing energy, and disappearing tracks, and determine the collider energy and luminosity required to probe the thermal Dark Matter masses. Larger multiplets are out of reach of any realistic future collider, but can be tested in future gamma ray telescopes and possibly in large-exposure liquid Xenon experiments.

hep-ph↗

Asymmetric accidental composite dark matter

The goal of this work is to find the simplest UV completion of Accidental Composite Dark Matter Models (ACDM) that can dynamically generate an asymmetry for the DM candidate, the lightest \textit{dark baryon} (DCb), and simultaneously annihilate the symmetric component. In this framework the DCb is a bound state of a confining $\text{SU}(N)_{\text{DC}}$ gauge group, and can interact weakly with the visible sector. The constituents of the DCb can possess non-trivial charges under the Standard Model gauge group. The generation of asymmetry for such candidate is a two-flavor variation of the \emph{out-of-equilibrium} decay of a heavy scalar, with mass $M_ϕ\gtrsim 10^{10}$ GeV. Below the scale of the scalars, the models recover accidental stability, or long-livedness, of the DM candidate. The symmetric component is annihilated by residual confined interactions provided that the mass of the DCb $m_{\text{DCb}} \lesssim 75$ TeV. We implement the mechanism of asymmetry generation, or a variation of it, in all the original ACDM models, managing to generate the correct asymmetry for DCb of masses in this range. For some of the models found, the stability of the DM candidate is not spoiled even considering generic GUT completions or asymmetry generation mechanisms in the visible sector.

hep-ph↗

First Results with the ANET Compact Thermal Neutron Collimator

This paper presents the first determination of the spatial resolution of the ANET Compact Neutron Collimator, obtained with a measuring campaign at the LENA Mark-II TRIGA reactor in Pavia. This novel collimator consists of a sequence of collimating and absorbing channels organised in a chessboard-like geometry. It has a scalable structure both in length and in the field of view. It is characterized by an elevated collimation power within a limited length. Its scalability and compactness are added values with respect to traditional collimating system. The prototype tested in this article is composed of 4 concatenated stages, each 100mm long, with a channel width of 2.5mm, delivering a nominal L/D factor of 160. This measuring campaign illustrates the use of the ANET collimator and its potential application in neutron imaging for facilities with small or medium size neutron sources.

physics.ins-det↗

Design of a novel compact neutron collimator

In this work the concept of a novel slow neutron collimator and the way to operate it are presented. The idea is based on the possibility to decouple the device field-of-view from its collimation power. A multi-channel geometry is proposed consisting of a chess-board structure where highly neutron-absorbing channels are alternated to air channels. A borated polymer was purposely developed to produce the attenuating components in the form of square-sectioned long rods. A scalable structure consisting of multiple collimation sectors can be arranged. The geometrical parameter LD, corresponding to the ratio between the length of a channel and its width, defines the collimation power. Several sectors can be arranged one after the other to reach relevant collimation powers. Each sector, 100 mm long, is composed by several channels with D = 2.5 mm corresponding to an L/D coefficient of 40. The target field of view is 50x50 mm2. This novel collimator, developed inside the INFN-ANET collaboration, due to its intrinsic compactness, will be of great importance to enhance the neutron imaging capability of small to medium-size neutron sources.

physics.ins-det↗

First application of machine learning algorithms to the position reconstruction in Resistive Silicon Detectors

RSDs (Resistive AC-Coupled Silicon Detectors) are n-in-p silicon sensors based on the LGAD (Low-Gain Avalanche Diode) technology, featuring a continuous gain layer over the whole sensor area. The truly innovative feature of these sensors is that the signal induced by an ionising particle is seen on several pixels, allowing the use of reconstruction techniques that combine the information from many read-out channels. In this contribution, the first application of a machine learning technique to RSD devices is presented. The spatial resolution of this technique is compared to that obtained with the standard RSD reconstruction methods that use analytical descriptions of the signal sharing mechanism. A Multi-Output regressor algorithm, trained with a combination of simulated and real data, leads to a spatial resolution of less than 2 $μm$ for a sensor with a 100 $μm$ pixel. The prospects of future improvements are also discussed.

physics.ins-det↗

The e_LiBANS facility: a new compact thermal neutron source based on a medical electron LINAC

A new photonuclear thermal neutron facility has been developed at the Physics Department of University of Torino. The facility is based on a medical electron LINAC coupled to a compact converter and moderator assembly. A homogenous thermal neutron field of the order of 10$^6$ cm$^{-2}$s$^{-1}$ is achievable in the enclosed irradiation cavity with low gamma and fast neutron contaminations. Its intensity can be tuned varying the LINAC current. These characteristics make the source appropriate for several applications like detectors development, material studies and BNCT preclinical research. This work describes the project and the experimental characterization of the facility. This includes the measurement of the thermal neutron fluence rate, the determination of the neutron energy spectrum and of the thermal neutron field uniformity and the evaluation of the gamma contamination.

physics.app-ph↗