Abstract
This paper presents the first determination of the spatial resolution of the ANET Compact Neutron Collimator, obtained with a measuring campaign at the LENA Mark-II TRIGA reactor in Pavia. This novel collimator consists of a sequence of collimating and absorbing channels organised in a chessboard-like geometry. It has a scalable structure both in length and in the field of view. It is characterized by an elevated collimation power within a limited length. Its scalability and compactness are added values with respect to traditional collimating system. The prototype tested in this article is composed of 4 concatenated stages, each 100mm long, with a channel width of 2.5mm, delivering a nominal L/D factor of 160. This measuring campaign illustrates the use of the ANET collimator and its potential application in neutron imaging for facilities with small or medium size neutron sources.
Explore related subjects
Keep this discovery
Oriol Sans-Planell, Marco Costa, Elisabetta Durisi, Ettore Mafucci, Luca Menzio, Valeria Monti, Lorenzo Visca, Francesco Grazzi, Roberto Bedogni, Saverio Altieri. 2021-10-18. First Results with the ANET Compact Thermal Neutron Collimator. https://doi.org/10.1088/1748-0221/16/11/p11025