SearcharxivSearch

arXiv subjects

Marco Faverzani

Publications and source records attributed to Marco Faverzani.

12 recordsLinked to original sources

Growth and characterization of planar hexagonal Ge on CdS

Hexagonal group-IV semiconductors have attracted increasing interest owing to their unconventional electronic and optical properties compared to the cubic diamond phase. However, the stabilization of these metastable allotropes in planar heterostructures remains a major challenge. In this work, we demonstrate the epitaxial growth of planar hexagonal germanium on non-basal $m$-plane CdS substrates by low-energy plasma-enhanced chemical vapor deposition. The role of growth temperature in the formation and stabilization of the hexagonal phase is investigated. X-ray diffraction, scanning transmission electron microscopy, and polarization-resolved Raman spectroscopy reveal the formation of epitaxial hexagonal germanium with the expected crystal symmetry. In particular, the Raman response exhibits the characteristic polarization selection rules of the E$_\text{2g}$ phonon mode of hexagonal Ge. Conversely, photoluminescence spectroscopy does not reveal any Ge-related emission feature. Combined transmission electron microscopy observations and atomistic modeling show that strain relaxation is governed by a limited set of dislocation mechanisms, which efficiently relieve most of the mismatch strain within a few nanometers from the interface and can involve localized cubic stacking insertions. At greater distances from the interface, the progressive loss of hexagonal order is increasingly dominated by stacking-fault disorder, particularly I3-type defects. These results establish CdS as a promising template for the planar stabilization of hexagonal Ge and provide insight into the defect mechanisms governing strain relaxation in metastable group-IV heterostructures.

cond-mat.mtrl-sci

NTL-amplified cryogenic light detectors with optically transparent electrodes

The Neganov-Trofimov-Luke (NTL) effect is used by experiments based on cryogenic detectors to boost the sensitivity of light-sensitive devices down to a few optical photons. In this work we introduce a silicon light-detector technology that implements NTL amplification at millikelvin temperatures using transparent indium-tin-oxide (ITO) electrodes. The ITO electrodes enable an electric field perpendicular to the wafer surface, mitigating surface charge recombination, and thanks to their optical properties, simultaneously serve as an anti-reflective coating. By combining these two functions in a single element, the fabrication process is simplified, yielding more robust and cost-effective devices. We report on the production and characterization of the first batch of these detectors. We performed a room-temperature characterization of the ITO electrodes, verifying the structural and optical characteristics of the deposited electrodes. We then operated 2 of these devices as cryogenic calorimeters at millikelvin temperatures. Finally, we develop a consistent analytical model for the NTL gain for both ionizing particles and optical photons, successfully describing the gain dependence on the NTL bias and explicitly accounting for the partial electrode coverage of the device surface.

physics.ins-det

Achieving speedup in Dark Matter search experiments with a transmon-based NISQ algorithm

Coherent detection of ultralight bosonic dark matter can be achieved by monitoring slow Rabi oscillations in superconducting qubits. We introduce an ancilla-assisted, gate-based protocol that enhances sensitivity to the hidden photon kinetic mixing parameter $\epsilon$ using a single two-qubit gate, bypassing the need to maintain long-lived multi-qubit entangled states and remaining compatible with the limitations of modern quantum hardware. We characterized the increase in sensitivity accounting for decoherence, thermal occupation, errors in readout and reset, indicating up to a ten-fold reduction in the required integration time to reach the same exclusion limit on $\epsilon$ achievable via Rabi-sampling experiments. Under plausible hardware assumptions and three years of data taking, the projected $95\%$ C.L. exclusion limit on the hidden photon mixing parameter reaches $\epsilon\approx 1\times 10^{-14}$ across $2.5$-$6.0$ GHz ($10$-$25$ \textmu eV).

quant-ph

Impact of embedded $^{163}$Ho on the performance of the transition-edge sensor microcalorimeters of the HOLMES experiment

We present a detailed investigation of the performance of transition-edge sensor (TES) microcalorimeters with $^{163}$Ho atoms embedded by ion implantation, as part of the HOLMES experiment aimed at neutrino mass determination. The inclusion of $^{163}$Ho atoms introduces an excess heat capacity due to a pronounced Schottky anomaly, which can affect the detector's energy resolution, signal height, and response time. We fabricated TES arrays with varying levels of $^{163}$Ho activity and characterized their performance in terms of energy resolution, decay time constants, and heat capacity. The intrinsic energy resolution was found to degrade with increasing $^{163}$Ho activity, consistent with the expected scaling of heat capacity. From the analysis, we determined the specific heat capacity of $^{163}$Ho to be $(2.9 \pm 0.4 \mathrm{(stat)} \pm 0.7 \mathrm{(sys)})$ J/K/mol at $(94 \pm 1)$\,mK, close to the literature values for metallic holmium. No additional long decay time constants correlated with $^{163}$Ho activity were observed, indicating that the excess heat capacity does not introduce weakly coupled thermodynamic systems. These results suggest that our present TES microcalorimeters can tolerate $^{163}$Ho activities up to approximately 5 Bq without significant performance degradation. For higher activities, reducing the TES transition temperature is necessary to maintain energy resolution. These findings provide critical insights for optimizing TES microcalorimeters for future neutrino mass experiments and other applications requiring embedded radioactive sources. The study also highlights the robustness of TES technology in handling implanted radionuclides while maintaining high-resolution performance.

physics.ins-det

On-chip pulse generation at 8 {\mu}m wavelength

The mid-infrared spectral region holds growing importance for applications such as gas sensing and spectroscopy. Although compact ultrashort pulse laser sources are essential to enable these applications, their realization in this spectral range remains an open challenge. We demonstrate an integrated approach to generate pulses in the mid-infrared based on chirped Bragg gratings engineered to compensate for the group delay dispersion of quantum cascade laser frequency comb sources. SiGe graded-index photonic circuits are used for operation around 8 {\mu}m wavelength. With this approach, pulses as short as 1.39 picoseconds were obtained, marking a key step towards fully integrated ultrashort pulse sources in the mid-infrared.

physics.optics

Nonlinear Behavior of Josephson Traveling Wave Parametric Amplifiers

Recent advancements in quantum technologies and advanced detection experiments have underscored the pressing need for the detection of exceedingly weak signals within the microwave frequency spectrum. Addressing this challenge, the Josephson Traveling Wave Parametric Amplifier (JTWPA) has been proposed as a cryogenic front-end amplifier capable of approaching the quantum noise limit while providing a relevant bandwidth. This research is centered on a comprehensive numerical investigation of the JTWPA, without resorting to simplifications regarding the nonlinearity of the essential components. Specifically, this study focuses on a thorough examination of the system, characterized by coupled nonlinear differential equations representing all components of the device. Proper input and output signals at the device's boundaries are considered. The analysis of the output signals undergoing the parametric amplification process involves a detailed exploration of phase-space dynamics and Fourier spectral analysis of the output voltage. This study is conducted while considering the parameters ruling the response of the device under pump and signal excitations. In addition to the expected signal amplification, the findings reveal that the nonlinear nature of the system can give rise to unforeseen phenomena, depending on the system's operational conditions, which include: the generation of pump tone harmonics, modulation of the signal gain, and incommensurate frequency generation-effects that are not easily accommodated by simplistic linearized approaches

cond-mat.supr-con

Broadband parametric amplification in DARTWARS

Superconducting parametric amplifiers offer the capability to amplify feeble signals with extremely low levels of added noise, potentially reaching quantum-limited amplification. This characteristic makes them essential components in the realm of high-fidelity quantum computing and serves to propel advancements in the field of quantum sensing. In particular, Traveling-Wave Parametric Amplifiers (TWPAs) may be especially suitable for practical applications due to their multi-Gigahertz amplification bandwidth, a feature lacking in Josephson Parametric Amplifiers (JPAs), despite the latter being a more established technology. This paper presents recent developments of the DARTWARS (Detector Array Readout with Traveling Wave AmplifieRS) project, focusing on the latest prototypes of Kinetic Inductance TWPAs (KITWPAs). The project aims to develop a KITWPA capable of achieving $20\,$ dB of amplification. To enhance the production yield, the first prototypes were fabricated with half the length and expected gain of the final device. In this paper, we present the results of the characterization of one of the half-length prototypes. The measurements revealed an average amplification of approximately $9\,$dB across a $2\,$GHz bandwidth for a KITWPA spanning $17\,$mm in length.

quant-ph

Development of KI-TWPAs for the DARTWARS project

Noise at the quantum limit over a broad bandwidth is a fundamental requirement for future cryogenic experiments for neutrino mass measurements, dark matter searches and Cosmic Microwave Background (CMB) measurements as well as for fast high-fidelity read-out of superconducting qubits. In the last years, Josephson Parametric Amplifiers (JPA) have demonstrated noise levels close to the quantum limit, but due to their narrow bandwidth, only few detectors or qubits per line can be read out in parallel. An alternative and innovative solution is based on superconducting parametric amplification exploiting the travelling-wave concept. Within the DARTWARS (Detector Array Readout with Travelling Wave AmplifieRS) project, we develop Kinetic Inductance Travelling-Wave Parametric Amplifiers (KI-TWPAs) for low temperature detectors and qubit read-out. KI-TWPAs are typically operated in a threewave mixing (3WM) mode and are characterised by a high gain, a high saturation power, a large amplification bandwidth and nearly quantum limited noise performance. The goal of the DARTWARS project is to optimise the KI-TWPA design, explore new materials, and investigate alternative fabrication processes in order to enhance the overall performance of the amplifier. In this contribution we present the advancements made by the DARTWARS collaboration to produce a working prototype of a KI-TWPA, from the fabrication to the characterisation.

quant-ph

Design and simulation of a transmon qubit chip for Axion detection

Quantum Sensing is a rapidly expanding research field that finds one of its applications in Fundamental Physics, as the search for Dark Matter. Devices based on superconducting qubits have already been successfully applied in detecting few-GHz single photons via Quantum Non-Demolition measurement (QND). This technique allows us to perform repeatable measurements, bringing remarkable sensitivity improvements and dark count rate suppression in experiments based on high-precision microwave photon detection, such as for Axions and Dark Photons search. In this context, the INFN Qub-IT project goal is to realize an itinerant single-photon counter based on superconducting qubits that will exploit QND for enhancing Axion search experiments. In this study, we present Qub-IT's status towards the realization of its first superconducting qubit device, illustrating design and simulation procedures and the characterization of fabricated Coplanar Waveguide Resonators (CPWs) for readout. We match target qubit parameters and assess a few-percent level agreement between lumped and distributed element simulation models. We reach a maximum internal quality factor of 9.2x10^5 for -92 dBm on-chip readout power.

quant-ph

High kinetic inductance NbTiN films for quantum limited travelling wave parametric amplifiers

A wide-bandwidth and low-noise amplification chain in the microwave regime is crucial for the efficient read-out of quantum systems based on superconducting detectors, such as Microwave Kinetic Inductance Detectors (MKIDs), Transition Edge Sensors (TESs), Magnetic Microcalorimeters (MMCs), and RF cavities, as well as qubits. Kinetic Inductance Travelling Wave Parametric Amplifiers (KI-TWPAs) operated in a three-wave mixing fashion have demonstrated exceptional dynamic range and low-noise performance, approaching the quantum limit. These amplifiers can be fabricated using a single layer of a high kinetic inductance film as weakly dispersive artificial transmission lines, with the ability to control the phase-matched bandwidth through dispersion engineering. In this study, we present the optimisation of the rf sputter-deposition process of NbTiN films using a Nb80%T20 target, with the goal of achieving precise control over film characteristics, resulting in high kinetic inductance while maintaining a high transition temperature. The parameter landscape related to the different sputtering conditions, such as pressure, power, and nitrogen flow, has been explored and the film thickness has been used as a fine-tuning parameter to adjust the properties of the final NbTiN films used for the fabrication of KI-TWPAs. As a final result, we have obtained a NbTiN film with a kinetic inductance of 8.5 pH/sq which we have exploited to fabricate KI-TWPA prototype devices, showing promising amplification performance.

physics.app-ph

The matrix optimum filter for Low Temperature Detectors dead-time reduction

Experiments aiming at high sensitivities usually demand for a very high statistics in order to reach more precise measurements. However, for those exploiting Low Temperature Detectors (LTDs), a high source activity may represent a drawback, if the events rate becomes comparable with the detector characteristic temporal response. Indeed, since commonly used optimum filtering approaches can only process LTDs signals well isolated in time, a non-negligible part of the recorded experimental data-set is discarded and hence constitute the dead-time. In the presented study we demonstrate that, thanks to the matrix optimum filtering approach, the dead-time of an experiment exploiting LTDs can be strongly reduced.

physics.data-an

Electron-phonon coupling in Ti/TiN MKIDs multilayer microresonator

Over the last few years there has been a growing interest toward the use of superconducting microwave microresonators operated in quasi-thermal equilibrium mode, especially applied to single particle detection. Indeed, previous devices designed and tested by our group with X-ray sources in the keV range evidenced that several issues arise from the attempt of detection through athermal quasiparticles produced within direct strikes of X-rays in the superconductor material of the resonator. In order to prevent issues related to quasiparticles self-recombination and to avoid exchange of athermal phonons with the substrate, our group focused on the development of thermal superconducting microresonators. In this configuration resonators composed of multilayer films of Ti/TiN sense the temperature of an absorbing material. To maximize the thermal response, low critical temperature films are preferable. By lowering the critical temperature, though, the maximum probing power bearable by the resonators decrease abruptly because of the weakening of the electron-phonon coupling. A proper compromise has to be found in order to avoid signal to noise ratio degradation. In this contribution we report the latest measurement of the electron-phonon coupling.

physics.ins-det