SearcharxivSearch

arXiv subjects

Maria Hempel

Publications and source records attributed to Maria Hempel.

3 recordsLinked to original sources

Design and performance of the Fast Beam Condition Monitor for luminosity and background measurement at the CMS Experiment in LHC Run 3

The Fast Beam Condition Monitor (BCM1F) has been used at the CMS Experiment since the first LHC circulating beams in 2008. Originally meant as a beam-induced background monitor for fast beam losses detection, it showed a potential also for luminosity measurements in 2012 running, and has been used for luminosity measurements since the beginning of Run 2 data taking in 2015 as a part of the Beam Radiation, Instrumentation and Luminosity (BRIL) system. Over the years, the system has undergone various upgrades to the sensors, the front-end and back-end electronics, providing improvements in the precision of the measurements, that remain valid in the higher pileup conditions of LHC Run 3 (2022-2026). Based on the experience of all BCM1F Run 2 upgrades, the detector was completely rebuilt prior to LHC Run 3 using AC-coupled silicon-pad diodes and active cooling. This latest detector version exhibits excellent linearity with instantaneous luminosity and achieves nanosecond-level timing precision, enabling improved systematic corrections for luminosity and background measurements. This paper presents a detailed overview of the detector system for LHC Run 3, including the selection and qualification of sensors as well as a summary of the readout system. It also outlines the processing and calibration strategy for luminosity data, discussing operational hurdles and comparing BCM1F measurements to other CMS luminosity measurements to assess the system's performance as a luminometer. Lastly, the implications for the design of a future luminosity detector to be used in the envisioned HL-LHC upgrade are discussed.

physics.ins-det

An Attack on Flexibility and Stoker's Problem

In view of solving problems of geometric realizability of polyhedra with given geometric constraints, we describe the space of geometric realizations of a simply-connected triangulated euclidean polyhedron in $\mathbb{R}^3$ up to similarity in terms of the angles of its faces and the angles between its faces. To do so we describe it as the set of its triangular faces glued together correspondingly and as the set of the polyhedral cones that it defines around its vertices. We recompute its dimension at smooth points modulo a combinatorial lemma.

math.MG

Fast Beam Condition Monitor for CMS: performance and upgrade

The CMS beam and radiation monitoring subsystem BCM1F (Fast Beam Condition Monitor) consists of 8 individual diamond sensors situated around the beam pipe within the pixel detector volume, for the purpose of fast bunch-by-bunch monitoring of beam background and collision products. In addition, effort is ongoing to use BCM1F as an online luminosity monitor. BCM1F will be running whenever there is beam in LHC, and its data acquisition is independent from the data acquisition of the CMS detector, hence it delivers luminosity even when CMS is not taking data. A report is given on the performance of BCM1F during LHC run I, including results of the van der Meer scan and on-line luminosity monitoring done in 2012. In order to match the requirements due to higher luminosity and 25 ns bunch spacing, several changes to the system must be implemented during the upcoming shutdown, including upgraded electronics and precise gain monitoring. First results from Run II preparation are shown.

physics.ins-det