SearcharxivSearch

arXiv subjects

Markus Kuster

Publications and source records attributed to Markus Kuster.

At least 19 recordsLinked to original sources

On the Influence of Parallax Effects in Thick Silicon Sensors in Coherent Diffraction Imaging

Structure determination is a key application of XFELs and 4th generation synchrotron sources, particularly using the coherent and pulsed X-ray radiation from X-ray free-electron lasers (XFEL). Scientific interest focuses on understanding the physical, biological, and chemical properties of samples at the nanometer scale. The X-rays from XFELs enable Coherent X-ray Diffraction Imaging (CXDI), where coherent X-rays irradiate a sample, and a far-field diffraction pattern is captured by an imaging detector. By the nature of the underlying physics, the resolution, at which the sample can be probed with the CXDI technique, is limited by the wavelength of the X-ray radiation and the exposure time if a detector can record the diffraction pattern to very large scattering angles. The resolution that can be achieved under real experimental conditions, depends strongly on additional parameters. The Shannon pixel size, linked to the detector resolution, the coherent dose that can be deposited in the sample without changing its structure, the image contrast, and the signal-to-noise ratio of the detected scattered radiation at high $q$, i.e. at high scattering angles $2\Theta$, have a strong influence on the resolution. The signal-to-noise ratio at high $q$ defines the "effective" maximum solid angle in a specific experiment setup up to which a detector can efficiently detect a signal and in consequence determines the achievable resolution. The image contrast defines how well bright image features can be distinguished from dark ones. We present the preliminary results of our study on the influence of the PSF on SNR, image contrast, position resolution, and achievable sample resolution for different pixel sizes.

physics.ins-det

Generation of Large Vortex-Free Superfluid Helium Nanodroplets

Superfluid helium nanodroplets are an ideal environment for the formation of metastable, self-organized dopant nanostructures. However, the presence of vortices often hinders their formation. Here, we demonstrate the generation of vortex-free helium nanodroplets and explore the size range in which they can be produced. From x-ray diffraction images of xenon-doped droplets, we identify that single compact structures, assigned to vortex-free aggregation, prevail up to $10^8$ atoms per droplet. This finding builds the basis for exploring the assembly of far-from-equilibrium nanostructures at low temperatures.

cond-mat.mes-hall

Megahertz-rate Ultrafast X-ray Scattering and Holographic Imaging at the European XFEL

The advent of X-ray free-electron lasers (XFELs) has revolutionized fundamental science, from atomic to condensed matter physics, from chemistry to biology, giving researchers access to X-rays with unprecedented brightness, coherence, and pulse duration. All XFEL facilities built until recently provided X-ray pulses at a relatively low repetition rate, with limited data statistics. Here, we present the results from the first megahertz repetition rate X-ray scattering experiments at the Spectroscopy and Coherent Scattering (SCS) instrument of the European XFEL. We illustrate the experimental capabilities that the SCS instrument offers, resulting from the operation at MHz repetition rates and the availability of the novel DSSC 2D imaging detector. Time-resolved magnetic X-ray scattering and holographic imaging experiments in solid state samples were chosen as representative, providing an ideal test-bed for operation at megahertz rates. Our results are relevant and applicable to any other non-destructive XFEL experiments in the soft X-ray range.

cond-mat.mes-hall

Design and first tests of the Gotthard-II readout ASIC for the European X-ray Free-Electron Laser

Gotthard-II is a charge-integrating microstrip detector developed for experiments and diagnostics at free-electron lasers using hard X-rays of 5 keV - 20 keV. Thanks to its excellent single photon sensitivity, large dynamic range as well as high frame rate of 4.5 MHz in burst mode, its potential scientific applications include X-ray absorption/emission spectroscopy, hard X-ray high resolution single-shot spectrometry (HiREX), beam diagnostics, as well as veto signal generation for pixel detectors. The Gotthard-II ASIC has been designed and fabricated using UMC-110 nm technology. The final ASIC design and performance in terms of noise, linearity, dynamic range, coupling between channels and speed will be discussed in the paper. In addition, a first measurement of an X-ray absorption spectrum of a standard copper sample has been done. The performance of the Gotthard-II in an experiment using energy dispersive X-rays has been demonstrated.

physics.ins-det

The 1-Megapixel pnCCD Detector for the Small Quantum Systems Instrument at the European XFEL: System and Operation Aspects

The X-ray free-electron lasers that became available during the last decade, like the European XFEL (EuXFEL), place high demands on their instrumentation. Especially at low photon energies below $1\,\text{keV}$, detectors with high sensitivity, and consequently low noise and high quantum efficiency, are required to enable facility users to fully exploit the scientific potential of the photon source. A 1-Megapixel pnCCD detector with a $1024\times 1024$ pixel format has been installed and commissioned for imaging applications at the Nano-Sized Quantum System (NQS) station of the Small Quantum System (SQS) instrument at EuXFEL. The instrument is currently operating in the energy range between $0.5$ and $3\,\text{keV}$ and the NQS station is designed for investigations of the interaction of intense FEL pulses with clusters, nano-particles and small bio-molecules, by combining photo-ion and photo-electron spectroscopy with coherent diffraction imaging techniques. The core of the imaging detector is a pn-type charge coupled device (pnCCD) with a pixel pitch of $75\,\mu\text{m}\times 75\,\mu\text{m}$. Depending on the experimental scenario, the pnCCD enables imaging of single photons thanks to its very low electronic noise of $3$e$^-$ and high quantum efficiency. Here we present an overview on the EuXFEL pnCCD detector and the results from the commissioning and first user operation at the SQS experiment in June 2019. The detailed descriptions of the detector design and capabilities, its implementation at EuXFEL both mechanically and from the controls side as well as important data correction steps aim to provide useful background for users planning and analyzing experiments at EuXFEL and may serve as a benchmark for comparing and planning future endstations at other FELs.

physics.ins-det

First functionality tests of a 64 x 64 pixel DSSC sensor module connected to the complete ladder readout

The European X-ray Free Electron Laser (XFEL.EU) will provide every 0.1 s a train of 2700 spatially coherent ultrashort X-ray pulses at 4.5 MHz repetition rate. The Small Quantum Systems (SQS) instrument and the Spectroscopy and Coherent Scattering instrument (SCS) operate with soft X-rays between 0.5 keV - 6keV. The DEPFET Sensor with Signal Compression (DSSC) detector is being developed to meet the requirements set by these two XFEL.EU instruments. The DSSC imager is a 1 mega-pixel camera able to store up to 800 single-pulse images per train. The so-called ladder is the basic unit of the DSSC detector. It is the single unit out of sixteen identical-units composing the DSSC-megapixel camera, containing all representative electronic components of the full-size system and allows testing the full electronic chain. Each DSSC ladder has a focal plane sensor with 128 x 512 pixels. The read-out ASIC provides full-parallel readout of the sensor pixels. Every read-out channel contains an amplifier and an analog filter, an up-to 9 bit ADC and the digital memory. The ASIC amplifier have a double front-end to allow one to use either DEPFET sensors or Mini-SDD sensors. In the first case, the signal compression is a characteristic intrinsic of the sensor; in the second case, the compression is implemented at the first amplification stage. The goal of signal compression is to meet the requirement of single-photon detection capability and wide dynamic range. We present the first results of measurements obtained using a 64 x 64 pixel DEPFET sensor attached to the full final electronic and data-acquisition chain.

physics.ins-det

Performance of the LBNL FastCCD for the European XFEL

The European X-ray Free Electron Laser (XFEL.EU) is currently being commissioned in Schenefeld, Germany. From 2017 onwards it will provide spatially coherent X-rays of energies between 0.25\,keV and 25\,keV with a unique timing structure. One of the detectors foreseen at XFEL.EU for the soft X-ray regime (energies below 6\,keV) is a quasi column-parallel readout FastCCD developed by Lawrence Berkeley National Lab (LBNL) specifically for the XFEL.EU requirements. Its sensor has 1920$\times$960 pixels of 30\,$\mu$m $\times$30\,$\mu$m size with a beam hole in the middle of the sensor. The camera can be operated in full frame and frame store mode. With the FastCCD a frame rate of up to 120~fps can be achieved, but at XFEL.EU the camera settings are optimized for the 10\,Hz XFEL bunch-mode. The detector has been delivered to XFEL.EU. Results of the performance tests and calibration done using the XFEL.EU detector calibration infrastructure are presented quantifying noise level, gain and energy resolution.

physics.ins-det

Safety-Interlock System of the DSSC X-Ray Imager

In this paper, the DSSC safety-interlock system is introduced. It is designed to keep the DSSC mega-pixel camera in a safe-state. The system is composed of four inter-communicating sub-systems referred here as a master SIB (safety-interlock board) and three partner SIBs. Each SIB monitors and processes 75 temperature sensors mainly located in the focal plane and also distributed inside the camera-head electronics. It monitors the signals from two pressure sensors, one humidity sensor as well as the connectivity to sixteen low-voltage and two high-voltage cables. The master SIB supervises the signals to and from external equipments like the cooling system, pressure gauge, power crates and status information from experimental environment. SIB is an 8-layer printed-circuit board (PCB) with a micro-controller sitting on top as its central processing unit. A decision-matrix software reads the sensor status continuously and determines whether the camera is in a safe state or not. All error and warnings flags are sent to the detector control software framework and the end user directly. These flags are also stored every 100 ms together with the image data. The full SIB sensor data is sent to the back end for offline analysis. A shutdown sequence is initiated by SIB in case of a critical failure. The safety-interlock philosophy, hardware design, and software architecture along with test results will be presented.

physics.ins-det

X-CSIT: a toolkit for simulating 2D pixel detectors

A new, modular toolkit for creating simulations of 2D X-ray pixel detectors, X-CSIT (X-ray Camera SImulation Toolkit), is being developed. The toolkit uses three sequential simulations of detector processes which model photon interactions, electron charge cloud spreading with a high charge density plasma model and common electronic components used in detector readout. In addition, because of the wide variety in pixel detector design, X-CSIT has been designed as a modular platform so that existing functions can be modified or additional functionality added if the specific design of a detector demands it. X-CSIT will be used to create simulations of the detectors at the European XFEL, including three bespoke 2D detectors: the Adaptive Gain Integrating Pixel Detector (AGIPD), Large Pixel Detector (LPD) and DePFET Sensor with Signal Compression (DSSC). These simulations will be used by the detector group at the European XFEL for detector characterisation and calibration. For this purpose, X-CSIT has been integrated into the European XFEL's software framework, Karabo. This will further make it available to users to aid with the planning of experiments and analysis of data. In addition, X-CSIT will be released as a standalone, open source version for other users, collaborations and groups intending to create simulations of their own detectors.

physics.ins-det

Geant4 and beyond: recent progress in precision physics modeling

This extended abstract briefly summarizes ongoing research activity on the evaluation and experimental validation of physics methods for photon and electron transport. The analysis includes physics models currently implemented in Geant4 as well as modeling methods used in other Monte Carlo codes, or not yet considered in general purpose Monte Carlo simulation systems. The validation of simulation models is performed with the support of rigorous statistical methods, which involve goodness-of-fit tests followed by categorical analysis. All results are quantitative, and are fully documented.

physics.comp-ph

Validation of Compton Scattering Monte Carlo Simulation Models

Several models for the Monte Carlo simulation of Compton scattering on electrons are quantitatively evaluated with respect to a large collection of experimental data retrieved from the literature. Some of these models are currently implemented in general purpose Monte Carlo systems; some have been implemented and evaluated for possible use in Monte Carlo particle transport for the first time in this study. Here we present first and preliminary results concerning total and differential Compton scattering cross sections.

physics.comp-ph

Performance of an LPD prototype detector at MHz frame rates under Synchrotron and FEL radiation

A MHz frame rate X-ray area detector (LPD - Large Pixel Detector) is under development by the Rutherford Appleton Laboratory for the European XFEL. The detector will have 1 million pixels and allows analogue storage of 512 images taken at 4.5 MHz in the detector front end. The LPD detector has 500 mm thick silicon sensor tiles that are bump bonded to a readout ASIC. The ASICs preamplifier provides relatively low noise at high speed which results in a high dynamic range of 10^5 photons over an energy range of 5-20 keV. Small scale prototypes of 32x256 pixels (LPD 2-Tile detector) and 256x256 pixels (LPD supermodule detector) are now available for X-ray tests. The performance of prototypes of the detector is reported for first tests under synchrotron radiation (PETRA III at DESY) and Free-Electron-Laser radiation (LCLS at SLAC). The initial performance of the detector in terms of signal range and noise, radiation hardness and spatial and temporal response are reported. The main result is that the 4.5 MHz sampling detection chain is reliably working, including the analogue on-chip memory concept. The detector is at least radiation hard up to 5 MGy at 12 keV. In addition the multiple gain concept has been demonstrated over a dynamic range to 10^4 at 12 keV with a readout noise equivalent to <1 photon rms in its most sensitive mode.

physics.ins-det

Radioactive Decays in Geant4

The simulation of radioactive decays is a common task in Monte-Carlo systems such as Geant4. Usually, a system either uses an approach focusing on the simulations of every individual decay or an approach which simulates a large number of decays with a focus on correct overall statistics. The radioactive decay package presented in this work permits, for the first time, the use of both methods within the same simulation framework - Geant4. The accuracy of the statistical approach in our new package, RDM-extended, and that of the existing Geant4 per-decay implementation (original RDM), which has also been refactored, are verified against the ENSDF database. The new verified package is beneficial for a wide range of experimental scenarios, as it enables researchers to choose the most appropriate approach for their Geant4-based application.

physics.comp-ph

Validation of Geant4-based Radioactive Decay Simulation

Radioactive decays are of concern in a wide variety of applications using Monte-Carlo simulations. In order to properly estimate the quality of such simulations, knowledge of the accuracy of the decay simulation is required. We present a validation of the original Geant4 Radioactive Decay Module, which uses a per-decay sampling approach, and of an extended package for Geant4-based simulation of radioactive decays, which, in addition to being able to use a refactored per-decay sampling, is capable of using a statistical sampling approach. The validation is based on measurements of calibration isotope sources using a high purity Germanium (HPGe) detector; no calibration of the simulation is performed. For the considered validation experiment equivalent simulation accuracy can be achieved with per-decay and statistical sampling.

physics.comp-ph

Status of detector development for the European XFEL

The European X-ray Free Electron Laser (XFEL.EU) will provide as-yet-unrivaled peak brilliance and ultra-short pulses of spatially coherent X-rays with a pulse length of less than 100 fs in the energy range between 0.25 and 25 keV. The high radiation intensity and ultra-short pulse duration will open a window for novel scientific techniques and will allow to explore new phenomena in biology, chemistry, material science, as well as matter at high energy density, atomic, ion and molecular physics. The variety of scientific applications and especially the unique XFEL.EU time structure require adequate instrumentation to be developed in order to exploit the full potential of the light source. To make optimal use of the unprecedented capabilities of the European XFEL and master these vast technological challenges, the European XFEL GmbH has started a detector R&D program. The technology concepts of the detector system presently under development are complementary in their performance and will cover the requirements of a large fraction of the scientific applications envisaged for the XFEL.EU facility. The actual status of the detector development projects which includes ultra-fast 2D imaging detectors, low repetition rate 2D detectors as well as strip detectors for e.g. spectroscopy applications and the infrastructure for the detectors' calibration and tests will be presented. Furthermore, an overview of the forthcoming implementation phase of the European XFEL in terms of detector R&D will be given.

physics.ins-det

Detector Development for the European XFEL: Requirements and Status

The variety of applications and especially the unique European XFEL time structure will require adequate instrumentation to be developed to exploit the full potential of the light source. Two-dimensional integrating X-ray detectors with ultra-fast read out up to 4.5 MHz for 1024 x 1024 pixel images are under development for a variety of imaging applications. The actual status of the European XFEL detector development projects is presented. Furthermore, an outlook will be given with respect to detector research and development, performance optimization, integration, and commissioning.

physics.ins-det

Background Simulations of the Wide Field Imager of the ATHENA X-Ray Observatory

The ATHENA X-ray Observatory-IXO is a planned multinational orbiting X-ray observatory with a focal length of 11.5m. ATHENA aims to perform pointed observations in an energy range from 0.1 keV to 15 keV with high sensitivity. For high spatial and timing resolution imaging and spectroscopic observations the 640x640 pixel^2 large DePFET-technology based Wide field Imager (WFI) focal plane detector, providing a field of view of 18 arcsec will be the main detector. Based on the actual mechanics, thermal and shielding design we present estimates for the WFI cosmic ray induced background obtained by the use of Monte-Carlo simulations and possible background reduction measures.

astro-ph.IM

Data libraries as a collaborative tool across Monte Carlo codes

The role of data libraries in Monte Carlo simulation is discussed. A number of data libraries currently in preparation are reviewed; their data are critically examined with respect to the state-of-the-art in the respective fields. Extensive tests with respect to experimental data have been performed for the validation of their content.

physics.comp-ph