SearcharxivSearch

arXiv · 1612.03642

Safety-Interlock System of the DSSC X-Ray Imager

Abstract

In this paper, the DSSC safety-interlock system is introduced. It is designed to keep the DSSC mega-pixel camera in a safe-state. The system is composed of four inter-communicating sub-systems referred here as a master SIB (safety-interlock board) and three partner SIBs. Each SIB monitors and processes 75 temperature sensors mainly located in the focal plane and also distributed inside the camera-head electronics. It monitors the signals from two pressure sensors, one humidity sensor as well as the connectivity to sixteen low-voltage and two high-voltage cables. The master SIB supervises the signals to and from external equipments like the cooling system, pressure gauge, power crates and status information from experimental environment. SIB is an 8-layer printed-circuit board (PCB) with a micro-controller sitting on top as its central processing unit. A decision-matrix software reads the sensor status continuously and determines whether the camera is in a safe state or not. All error and warnings flags are sent to the detector control software framework and the end user directly. These flags are also stored every 100 ms together with the image data. The full SIB sensor data is sent to the back end for offline analysis. A shutdown sequence is initiated by SIB in case of a critical failure. The safety-interlock philosophy, hardware design, and software architecture along with test results will be presented.

Explore related subjects

Keep this discovery

BibTeXRIS

Sneha Nidhi, Helmut Klaer, Karsten Hansen, Monica Turcato, Markus Kuster, Matteo Porro. 2016-12-12. Safety-Interlock System of the DSSC X-Ray Imager. https://arxiv.org/abs/1612.03642

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det