Searcharxiv⌕ Search

arXiv subjects

Maryvonne De Jesus

Publications and source records attributed to Maryvonne De Jesus.

4 recordsLinked to original sources

Single-electron detection in a high-purity Ge device

High-purity germanium (HPGe) detectors are among the most powerful instruments for gamma ray spectroscopy, combining exceptional energy resolution with large active volumes. Although they operate close to the fundamental resolution limit at high energies, their performance at very low energies has long been limited by electronic noise, restricting detection thresholds to above approximately 30 electron-hole pairs ($\sim$100 eV). Here we introduce a cryogenic HPGe detector architecture that achieves single electron-hole pair sensitivity by calorimetrically measuring ionization at temperatures near 20 mK. The device integrates a NbSi transition-edge sensor into a point-contact-inspired geometry, concentrating athermal phonon energy generated during charge drift and enabling eV-scale sensitivity ultimately set by the semiconductor band gap. Beyond single-charge detection, the device rejects the low-energy excess background that limits existing cryogenic low-threshold technologies, establishing a pathway towards discrimination between electron- and nuclear-recoil events below 100 eV. These advances open a route towards next-generation detectors for direct dark matter searches, coherent elastic neutrino-nucleus scattering, and nuclear reactor monitoring for non-proliferation applications.

physics.ins-det↗

Characterization of Aluminum Microwave SQUID Multiplexers for CE$ν$NS Detection

We present the design, fabrication, and characterization of an aluminum-based six-channel microwave SQUID multiplexer ($μ$MUX) prototype for transition-edge sensor (TES) readout in the RICOCHET experiment. The device consists of aluminum coplanar-waveguide resonators and RF SQUIDs with Dolan-style Al/AlO$_x$/Al Josephson junctions. By measuring the resonator scattering parameters at a range of probe tone frequencies, powers, and flux bias points, we demonstrate agreement between the device response and existing multiplexer models. We also characterize the noise performance in both open-loop and flux-ramping modes. With a high electron mobility transistor (HEMT) amplifier, open-loop measurements yield a flux sensitivity of 1-1.5 $μΦ_0/\sqrt{Hz}$. With flux-ramp modulation, low-frequency 1/f noise is suppressed, and the flux sensitivity is around 3-4 $μΦ_0/\sqrt{Hz}$, corresponding to a current sensitivity of 24-33 $pA/\sqrt{Hz}$ at the input coil. We further demonstrate a reduction in readout noise by incorporating a Josephson traveling-wave parametric amplifier (JTWPA) between the $μ$MUX and the HEMT. This achieves an open-loop flux sensitivity of 0.3-0.6 $μΦ_0/\sqrt{Hz}$ and an effective system noise temperature below 1 K. These results establish aluminum $μ$MUX devices as a viable and extensible readout technology for low-noise cryogenic detector arrays.

physics.ins-det↗

Characterization of mini-CryoCube detectors from the Ricochet experiment commissioning at the Institut Laue-Langevin

The Ricochet experiment aims to measure the coherent elastic neutrino-nucleus scattering process from antineutrinos emitted by a research nuclear reactor operated by the Institut Laue-Langevin (Grenoble, France). This article presents a description of the Ricochet experimental installation and the detector performance achieved during its commissioning with a mini-CryoCube module consisting of three 42-gram germanium cryogenic calorimeters. The baseline resolutions and background levels are reported both during reactor-on and reactor-off periods, and as noise mitigation techniques were improved. A baseline resolution of 40 eV electron equivalent was achieved for the ionization channel after setup improvements, and the phonon channel resolutions ranged from 50 to 80 eV of total phonon energy. In the energy region from 2 to 7 keV, a nuclear recoil rate of 15(2) events/(kg day keV) is measured during the reactor-off period selecting events in coincidence with muon veto signals. This rate is in agreement with the cosmogenic neutron rate calculated from GEANT4 simulations. After the rejection of events in coincidence with signals in the muon veto detectors, a combined 90% C.L. limit on the nuclear recoil background of < 9 events/(kg day keV) is obtained in that energy region during the reactor-on period, which is compatible with our GEANT4 model calculation corresponding to a total rate of 5 events/(kg day keV). The sensitivity of this analysis was however found to be limited by a surface event contamination which is currently being addressed by the Ricochet Collaboration with upgraded detectors.

hep-ex↗

Contact-less phonon detection with massive cryogenic absorbers

We have developed a contact-less technique for the real time measurement of a-thermal (Cooper-pair breaking) phonons in an absorber held at sub-Kelvin temperatures. In particular, a thin-film aluminum superconducting resonator was realized on a 30-grams high-resistivity silicon crystal. The lumped-element resonator is inductively excited/read-out by a radio-frequency microstrip feed-line deposited on another wafer; the sensor, a Kinetic Inductance Detector (KID), is read-out without any physical contact or wiring to the absorber. The resonator demonstrates excellent electrical properties, particularly in terms of its internal quality factor. The detection of alphas and gammas in the massive absorber is achieved, with an RMS energy resolution of about 1.4 keV, which is already interesting for particle physics applications. The resolution of this prototype detector is mainly limited by the low (about 0.3%) conversion efficiency of deposited energy to superconducting excitations (quasi-particles). The demonstrated technique can be further optimized, and used to produce large arrays of a-thermal phonon detectors, for use in rare events searches such as: dark matter direct detection,neutrino-less double beta decay, or coherent elastic neutrino-nucleus scattering.

physics.ins-det↗