SearcharxivSearch

arXiv subjects

Matthew S. Rosen

Publications and source records attributed to Matthew S. Rosen.

At least 19 recordsLinked to original sources

Disease Is a Spectral Perturbation

We propose a novel method of understanding disease transformation from a healthy baseline with biomarker-level explainability. By modeling the biomarker covariance matrices of healthy controls and disease states, the perturbation can be individually characterized to accomplish mechanistic explanations of disease trajectories, both at a molecular level and for individual patients. Given a cohort of n patients each measured on p biomarkers, we define the biomarker "Hamiltonian" H = X^T X / n \in R^{p \times p}, where X \in R^{n \times p} is the covariant biomarker matrix. The eigenvectors of H define a set of normal modes of biomarker coordination, and the eigenvalues quantify the energy carried by each mode. In the healthy state, the reference Hamiltonian H_0 governs this structure where disease perturbs H_0 by an additive operator ΔH, thus shifting eigenvalues and rotating eigenvectors in proportion to the severity of pathological disruption. We formalize this framework, derive the spectral change given a disease perturbation, and demonstrate that the projection of a newly diagnosed patient's cumulative biomarker covariance structure onto disease-discriminant eigenmodes constitutes an optimal prognostic statistic for greater precision in disease prognosis. This work serves as a veritable white paper with application across a panoply of disease frameworks from cancer to neurodegenerative disorders.

cs.LG

Enhanced Portable Ultra Low-Field Diffusion Tensor Imaging with Bayesian Artifact Correction and Deep Learning-Based Super-Resolution

Portable, ultra-low-field (ULF) magnetic resonance imaging has the potential to expand access to neuroimaging but currently suffers from coarse spatial and angular resolutions and low signal-to-noise ratios. Diffusion tensor imaging (DTI), a sequence tailored to detect and reconstruct white matter tracts within the brain, is particularly prone to such imaging degradation due to inherent sequence design coupled with prolonged scan times. In addition, ULF DTI scans exhibit artifacting that spans both the space and angular domains, requiring a custom modelling algorithm for subsequent correction. We introduce a nine-direction, single-shell ULF DTI sequence, as well as a companion Bayesian bias field correction algorithm that possesses angular dependence and convolutional neural network-based superresolution algorithm that is generalizable across DTI datasets and does not require re-training (''DiffSR''). We show through a synthetic downsampling experiment and white matter assessment in real, matched ULF and high-field DTI scans that these algorithms can recover microstructural and volumetric white matter information at ULF. We also show that DiffSR can be directly applied to white matter-based Alzheimers disease classification in synthetically degraded scans, with notable improvements in agreement between DTI metrics, as compared to un-degraded scans. We freely disseminate the Bayesian bias correction algorithm and DiffSR with the goal of furthering progress on both ULF reconstruction methods and general DTI sequence harmonization. We release all code related to DiffSR for $\href{https://github.com/markolchanyi/DiffSR}{public \space use}$.

cs.CV

Reference-Free 3D Reconstruction of Brain Dissection Slabs via Learned Atlas Coordinates

Correlation of neuropathology with MRI has the potential to transfer microscopic signatures of pathology to in vivo scans. There is increasing interest in building these correlations from 3D reconstructed stacks of slab photographs, which are routinely taken during dissection at brain banks. These photographs bypass the need for ex vivo MRI, which is not widely accessible. However, existing methods either require a corresponding 3D reference (e.g., an ex vivo MRI scans, or a brain surface acquired with a structured light scanner) or a full stack of brain slabs, which severely limits applicability. Here we propose RefFree, a 3D reconstruction method for dissection photographs that does not require an external reference. RefFree coherently reconstructs a 3D volume for an arbitrary set of slabs (including a single slab) using predicted 3D coordinates in the standard atlas space (MNI) as guidance. To support RefFree's pipeline, we train an atlas coordinate prediction network that estimates the coordinate map from a 2D photograph, using synthetic photographs generated from digitally sliced 3D MRI data with randomized appearance for enhanced generalization. As a by-product, RefFree can propagate information (e.g., anatomical labels) from atlas space to one single photograph even without reconstruction. Experiments on simulated and real data show that, when all slabs are available, RefFree achieves performance comparable to existing classical methods but at substantially higher speed. Moreover, RefFree yields accurate reconstruction and registration for partial stacks or even a single slab. Our code is available at https://github.com/lintian-a/reffree.

eess.IV

Accelerating Low-field MRI: From Compressed Sensing to Deep Learning Reconstruction with CNNs and Transformers

Portable, low-field Magnetic Resonance Imaging (MRI) scanners are increasingly being deployed in clinical settings. However, key barriers to their widespread use include low signal-to-noise ratio (SNR), generally low image quality, and long scan durations. Hence, methods for accelerating acquisition and boosting image quality are critically important to enable clinically actionable, high-quality imaging in these systems. Despite the role that compressed sensing (CS) and deep learning (DL)-based methods have played in improving image quality for high-field MRI, their adoption for low-field imaging is still in its infancy, and it remains unclear how robust these methods are in low-SNR regimes. Here, we propose, investigate, and compare four reconstruction approaches: (i) L1-wavelet CS; (ii) a data-driven network; (iii) an unrolled network; and (iv) a Swin Transformer Cascade. We evaluate their performance across a range of SNR values using publicly available datasets and ultra-low field (6.5 mT) MRI data. Our results show that the unrolled network and Swin Transformer cascade outperform CS and data-driven models. While transformer-based models achieve the highest performance at high SNR, unrolled convolution-based networks are more robust in ultra-low SNR settings and often outperform transformers, indicating that simpler DL architectures may be better suited to low-field MRI. This work highlights both the potential and limitations of advanced reconstruction techniques in low-field MRI and pinpoints effective DL strategies for addressing SNR challenges.

physics.med-ph

Ultra-low field 13C MRI of hyperpolarized pyruvate

Medicine is evolving beyond therapy largely predicated on anatomical information and towards incorporating patient-specific molecular biomarkers of disease for more accurate diagnosis and effective treatment. The complementary combination of hyperpolarization by spin-lock induced crossing signal amplification by reversible exchange (SLIC SABRE) and low field magnetic resonance imaging (MRI) can enable accessible metabolic imaging to advance personalized medicine. Hyperpolarized 13C-enriched pyruvate has demonstrated utility for MRI of metabolism in cancer, heart disease and neurodegenerative disorders but has been restricted from widespread clinical adoption by a lack of access to affordable technology. Parahydrogen-based polarization techniques, paired with low-cost high-performance MRI at millitesla fields, offer a means of broadening the reach of metabolic imaging. Here we show results demonstrating in situ hyperpolarization of pyruvate at 6.5 mT by SLIC SABRE, followed by immediate readout without field cycling or sample shuttling. We achieve 13C signal enhancements several million times above thermal equilibrium at 6.5 mT, corresponding to polarization levels of approximately 3%. Leveraging this enhancement, we perform 13C MRI and acquire NMR spectra with resolution sufficient to distinguish chemical shifts between pyruvate isotopomers. These results show a viable pathway towards accessible metabolic imaging with hyperpolarized 13C MRI at ultra-low field.

physics.med-ph

From Low Field to High Value: Robust Cortical Mapping from Low-Field MRI

Three-dimensional reconstruction of cortical surfaces from MRI for morphometric analysis is fundamental for understanding brain structure. While high-field MRI (HF-MRI) is standard in research and clinical settings, its limited availability hinders widespread use. Low-field MRI (LF-MRI), particularly portable systems, offers a cost-effective and accessible alternative. However, existing cortical surface analysis tools are optimized for high-resolution HF-MRI and struggle with the lower signal-to-noise ratio and resolution of LF-MRI. In this work, we present a machine learning method for 3D reconstruction and analysis of portable LF-MRI across a range of contrasts and resolutions. Our method works "out of the box" without retraining. It uses a 3D U-Net trained on synthetic LF-MRI to predict signed distance functions of cortical surfaces, followed by geometric processing to ensure topological accuracy. We evaluate our method using paired HF/LF-MRI scans of the same subjects, showing that LF-MRI surface reconstruction accuracy depends on acquisition parameters, including contrast type (T1 vs T2), orientation (axial vs isotropic), and resolution. A 3mm isotropic T2-weighted scan acquired in under 4 minutes, yields strong agreement with HF-derived surfaces: surface area correlates at r=0.96, cortical parcellations reach Dice=0.98, and gray matter volume achieves r=0.93. Cortical thickness remains more challenging with correlations up to r=0.70, reflecting the difficulty of sub-mm precision with 3mm voxels. We further validate our method on challenging postmortem LF-MRI, demonstrating its robustness. Our method represents a step toward enabling cortical surface analysis on portable LF-MRI. Code is available at https://surfer.nmr.mgh.harvard.edu/fswiki/ReconAny

cs.CV

Deep learning of personalized priors from past MRI scans enables fast, quality-enhanced point-of-care MRI with low-cost systems

Magnetic resonance imaging (MRI) offers superb-quality images, but its accessibility is limited by high costs, posing challenges for patients requiring longitudinal care. Low-field MRI provides affordable imaging with low-cost devices but is hindered by long scans and degraded image quality, including low signal-to-noise ratio (SNR) and tissue contrast. We propose a novel healthcare paradigm: using deep learning to extract personalized features from past standard high-field MRI scans and harnessing them to enable accelerated, enhanced-quality follow-up scans with low-cost systems. To overcome the SNR and contrast differences, we introduce ViT-Fuser, a feature-fusion vision transformer that learns features from past scans, e.g. those stored in standard DICOM CDs. We show that \textit{a single prior scan is sufficient}, and this scan can come from various MRI vendors, field strengths, and pulse sequences. Experiments with four datasets, including glioblastoma data, low-field ($50mT$), and ultra-low-field ($6.5mT$) data, demonstrate that ViT-Fuser outperforms state-of-the-art methods, providing enhanced-quality images from accelerated low-field scans, with robustness to out-of-distribution data. Our freely available framework thus enables rapid, diagnostic-quality, low-cost imaging for wide healthcare applications.

eess.IV

TV-based Deep 3D Self Super-Resolution for fMRI

While functional Magnetic Resonance Imaging (fMRI) offers valuable insights into cognitive processes, its inherent spatial limitations pose challenges for detailed analysis of the fine-grained functional architecture of the brain. More specifically, MRI scanner and sequence specifications impose a trade-off between temporal resolution, spatial resolution, signal-to-noise ratio, and scan time. Deep Learning (DL) Super-Resolution (SR) methods have emerged as a promising solution to enhance fMRI resolution, generating high-resolution (HR) images from low-resolution (LR) images typically acquired with lower scanning times. However, most existing SR approaches depend on supervised DL techniques, which require training ground truth (GT) HR data, which is often difficult to acquire and simultaneously sets a bound for how far SR can go. In this paper, we introduce a novel self-supervised DL SR model that combines a DL network with an analytical approach and Total Variation (TV) regularization. Our method eliminates the need for external GT images, achieving competitive performance compared to supervised DL techniques and preserving the functional maps.

eess.IV

Machine Learning for Improved Current Density Reconstruction from 2D Vector Magnetic Images

The reconstruction of electrical current densities from magnetic field measurements is an important technique with applications in materials science, circuit design, quality control, plasma physics, and biology. Analytic reconstruction methods exist for planar currents, but break down in the presence of high spatial frequency noise or large standoff distance, restricting the types of systems that can be studied. Here, we demonstrate the use of a deep convolutional neural network for current density reconstruction from two-dimensional (2D) images of vector magnetic fields acquired by a quantum diamond microscope (QDM) utilizing a surface layer of Nitrogen Vacancy (NV) centers in diamond. Trained network performance significantly exceeds analytic reconstruction for data with high noise or large standoff distances. This machine learning technique can perform quality inversions on lower SNR data, reducing the data collection time by a factor of about 400 and permitting reconstructions of weaker and three-dimensional current sources.

physics.comp-ph

Probabilistic Contrastive Learning with Explicit Concentration on the Hypersphere

Self-supervised contrastive learning has predominantly adopted deterministic methods, which are not suited for environments characterized by uncertainty and noise. This paper introduces a new perspective on incorporating uncertainty into contrastive learning by embedding representations within a spherical space, inspired by the von Mises-Fisher distribution (vMF). We introduce an unnormalized form of vMF and leverage the concentration parameter, kappa, as a direct, interpretable measure to quantify uncertainty explicitly. This approach not only provides a probabilistic interpretation of the embedding space but also offers a method to calibrate model confidence against varying levels of data corruption and characteristics. Our empirical results demonstrate that the estimated concentration parameter correlates strongly with the degree of unforeseen data corruption encountered at test time, enables failure analysis, and enhances existing out-of-distribution detection methods.

cs.LG

Resolution- and Stimulus-agnostic Super-Resolution of Ultra-High-Field Functional MRI: Application to Visual Studies

High-resolution fMRI provides a window into the brain's mesoscale organization. Yet, higher spatial resolution increases scan times, to compensate for the low signal and contrast-to-noise ratio. This work introduces a deep learning-based 3D super-resolution (SR) method for fMRI. By incorporating a resolution-agnostic image augmentation framework, our method adapts to varying voxel sizes without retraining. We apply this innovative technique to localize fine-scale motion-selective sites in the early visual areas. Detection of these sites typically requires a resolution higher than 1 mm isotropic, whereas here, we visualize them based on lower resolution (2-3mm isotropic) fMRI data. Remarkably, the super-resolved fMRI is able to recover high-frequency detail of the interdigitated organization of these sites (relative to the color-selective sites), even with training data sourced from different subjects and experimental paradigms -- including non-visual resting-state fMRI, underscoring its robustness and versatility. Quantitative and qualitative results indicate that our method has the potential to enhance the spatial resolution of fMRI, leading to a drastic reduction in acquisition time.

eess.IV

Quantifying white matter hyperintensity and brain volumes in heterogeneous clinical and low-field portable MRI

Brain atrophy and white matter hyperintensity (WMH) are critical neuroimaging features for ascertaining brain injury in cerebrovascular disease and multiple sclerosis. Automated segmentation and quantification is desirable but existing methods require high-resolution MRI with good signal-to-noise ratio (SNR). This precludes application to clinical and low-field portable MRI (pMRI) scans, thus hampering large-scale tracking of atrophy and WMH progression, especially in underserved areas where pMRI has huge potential. Here we present a method that segments white matter hyperintensity and 36 brain regions from scans of any resolution and contrast (including pMRI) without retraining. We show results on eight public datasets and on a private dataset with paired high- and low-field scans (3T and 64mT), where we attain strong correlation between the WMH ($ρ$=.85) and hippocampal volumes (r=.89) estimated at both fields. Our method is publicly available as part of FreeSurfer, at: http://surfer.nmr.mgh.harvard.edu/fswiki/WMH-SynthSeg.

eess.IV

Uncertainty Estimation and Out-of-Distribution Detection for Deep Learning-Based Image Reconstruction using the Local Lipschitz

Accurate image reconstruction is at the heart of diagnostics in medical imaging. Supervised deep learning-based approaches have been investigated for solving inverse problems including image reconstruction. However, these trained models encounter unseen data distributions that are widely shifted from training data during deployment. Therefore, it is essential to assess whether a given input falls within the training data distribution for diagnostic purposes. Uncertainty estimation approaches exist but focus on providing an uncertainty map to radiologists, rather than assessing the training distribution fit. In this work, we propose a method based on the local Lipschitz-based metric to distinguish out-of-distribution images from in-distribution with an area under the curve of 99.94%. Empirically, we demonstrate a very strong relationship between the local Lipschitz value and mean absolute error (MAE), supported by a high Spearman's rank correlation coefficient of 0.8475, which determines the uncertainty estimation threshold for optimal model performance. Through the identification of false positives, the local Lipschitz and MAE relationship was used to guide data augmentation and reduce model uncertainty. Our study was validated using the AUTOMAP architecture for sensor-to-image Magnetic Resonance Imaging (MRI) reconstruction. We compare our proposed approach with baseline methods: Monte-Carlo dropout and deep ensembles, and further analysis included MRI denoising and Computed Tomography (CT) sparse-to-full view reconstruction using UNET architectures. We show that our approach is applicable to various architectures and learned functions, especially in the realm of medical image reconstruction, where preserving the diagnostic accuracy of reconstructed images remains paramount.

cs.CV

A statistical learning framework for mapping indirect measurements of ergodic systems to emergent properties

The discovery of novel experimental techniques often lags behind contemporary theoretical understanding. In particular, it can be difficult to establish appropriate measurement protocols without analytic descriptions of the underlying system-of-interest. Here we propose a statistical learning framework that avoids the need for such descriptions for ergodic systems. We validate this framework by using Monte Carlo simulation and deep neural networks to learn a mapping between low-field nuclear magnetic resonance spectra and proton exchange rates in ethanol-water mixtures. We found that trained networks exhibited normalized-root-mean-square errors of less than 1% for exchange rates under 150 s-1 but performed poorly for rates above this range. This differential performance occurred because low-field measurements are indistinguishable from one another at fast exchange. Nonetheless, where a discoverable relationship between indirect measurements and emergent dynamics exists, we demonstrate the possibility of approximating it without the need for precise analytic descriptions, allowing experimental science to flourish in the midst of ongoing theoretical work

physics.data-an

Synthetic Low-Field MRI Super-Resolution Via Nested U-Net Architecture

Low-field (LF) MRI scanners have the power to revolutionize medical imaging by providing a portable and cheaper alternative to high-field MRI scanners. However, such scanners are usually significantly noisier and lower quality than their high-field counterparts. The aim of this paper is to improve the SNR and overall image quality of low-field MRI scans to improve diagnostic capability. To address this issue, we propose a Nested U-Net neural network architecture super-resolution algorithm that outperforms previously suggested deep learning methods with an average PSNR of 78.83 and SSIM of 0.9551. We tested our network on artificial noisy downsampled synthetic data from a major T1 weighted MRI image dataset called the T1-mix dataset. One board-certified radiologist scored 25 images on the Likert scale (1-5) assessing overall image quality, anatomical structure, and diagnostic confidence across our architecture and other published works (SR DenseNet, Generator Block, SRCNN, etc.). We also introduce a new type of loss function called natural log mean squared error (NLMSE). In conclusion, we present a more accurate deep learning method for single image super-resolution applied to synthetic low-field MRI via a Nested U-Net architecture.

eess.IV

On Real-time Image Reconstruction with Neural Networks for MRI-guided Radiotherapy

MRI-guidance techniques that dynamically adapt radiation beams to follow tumor motion in real-time will lead to more accurate cancer treatments and reduced collateral healthy tissue damage. The gold-standard for reconstruction of undersampled MR data is compressed sensing (CS) which is computationally slow and limits the rate that images can be available for real-time adaptation. Here, we demonstrate the use of automated transform by manifold approximation (AUTOMAP), a generalized framework that maps raw MR signal to the target image domain, to rapidly reconstruct images from undersampled radial k-space data. The AUTOMAP neural network was trained to reconstruct images from a golden-angle radial acquisition, a benchmark for motion-sensitive imaging, on lung cancer patient data and generic images from ImageNet. Model training was subsequently augmented with motion-encoded k-space data derived from videos in the YouTube-8M dataset to encourage motion robust reconstruction. We find that AUTOMAP-reconstructed radial k-space has equivalent accuracy to CS but with much shorter processing times after initial fine-tuning on retrospectively acquired lung cancer patient data. Validation of motion-trained models with a virtual dynamic lung tumor phantom showed that the generalized motion properties learned from YouTube lead to improved target tracking accuracy. Our work shows that AUTOMAP can achieve real-time, accurate reconstruction of radial data. These findings imply that neural-network-based reconstruction is potentially superior to existing approaches for real-time image guidance applications.

physics.med-ph

Homonuclear J-Coupling Spectroscopy using J-Synchronized Echo Detection

In the strong coupling regime with J-coupling much larger than chemical shift differences, J-coupling spectroscopy enables spectral identification of molecules even when conventional NMR fails. While this classically required the presence of a heteronucleus, we recently showed that J-coupling spectra can be acquired in many homonuclear systems using spin-lock induced crossing (SLIC). Here, we present an alternative method using a spin echo train in lieu of a spin-locking SLIC pulse, which has a number of advantages. In particular, spin echo acquisition within the pulse train enables simultaneous collection of time and frequency data. The resulting 2D spectrum can be used to study dynamic spin evolution, and the time domain data can be averaged to create a 1D J-coupling spectrum with increased signal-to-noise ratio.

physics.chem-ph

RASER MRI: Magnetic Resonance Images formed Spontaneously exploiting Cooperative Nonlinear Interaction

The spatial resolution of magnetic resonance imaging (MRI) is fundamentally limited by the width of Lorentzian point spread functions (PSF) associated with the exponential decay rate of transverse magnetization (1/T2*). Here we show a different contrast mechanism in MRI by establishing RASER (Radio-frequency Amplification by Stimulated Emission of Radiation) in imaged media. RASER imaging bursts emerge out of noise and without applying (Radio Frequency) RF pulses when placing spins with sufficient population inversion in a weak magnetic field gradient. A small difference in initial population inversion density creates a stronger image contrast than conventional MRI. This contrast is based on the cooperative nonlinear interaction between all slices. On the other hand, the cooperative nonlinear interaction gives rise to imaging artifacts, such as amplitude distortions and side lobes outside of the imaging domain. Both the contrast and the artifacts are demonstrated experimentally and predicted by simulations based on a proposed theory. This theory of RASER MRI is strongly connected to many other distinct fields related to synergetics and non-linear dynamics.

physics.med-ph