SearcharxivSearch

arXiv subjects

Maxim Masyukov

Publications and source records attributed to Maxim Masyukov.

2 recordsLinked to original sources

Permittivity Characterization of 3D-Printed Materials at Millimeter Waves

In this study, we characterize the permittivity of various commercially available materials commonly used in 3D printing over the millimeter-wave frequency range of 70-110 GHz. The open-waveguide extraction method is employed to efficiently determine the permittivity of these 3D-printed materials, and key strategies for improving its accuracy are discussed. This methodology can be readily applied to the characterization of similar materials and extended to higher frequency ranges. The resulting permittivity data are expected to support advances in 6G and beyond wireless communication technologies, in which 3D-printed materials and millimeter-wave frequencies are anticipated to play an increasingly important role in the development of novel antennas and metasurfaces.

physics.optics

Quasioptic, Calibrated, Full 2-port Measurements of Cryogenic Devices under Vacuum in the 220-330 GHz Band

A quasi-optical (QO) test bench was designed, simulated, and calibrated for characterizing S-parameters of devices in the 220-330 GHz (WR-3.4) frequency range, from room temperature down to 4.8 K. The devices were measured through vacuum windows via focused beam radiation. A de-embedding method employing line-reflect-match (LRM) calibration was established to account for the effects of optical components and vacuum windows. The setup provides all four S-parameters with the reference plane located inside the cryostat, and achieves a return loss of 30 dB with an empty holder. System validation was performed with measurements of cryogenically cooled devices, such as bare silicon wafers and stainless-steel frequency-selective surface (FSS) bandpass filters, and superconducting bandpass FSS fabricated in niobium. A permittivity reduction of Si based on 4-GHz resonance shift was observed concomitant with a drop in temperature from 296 K to 4.8 K. The stainless steel FSS measurements revealed a relatively temperature invariant center frequency and return loss level of 263 GHz and 35 dB on average, respectively. Finally, a center frequency of 257 GHz was measured with the superconducting filters, with return loss improved by 7 dB on average at 4.8 K. To the best of our knowledge, this is the first reported attempt to scale LRM calibration to 330 GHz and use it to de-embed the impact of optics and cryostat from cryogenically cooled device S-parameters.

physics.ins-det