Searcharxiv⌕ Search

arXiv subjects

Maximilian Lindholz

Publications and source records attributed to Maximilian Lindholz.

4 recordsLinked to original sources

Weight-Space Programming for Medical Imaging: Do We Still Need Training Data?

Can a large language model (LLM) write the parameters of a medical image classifier from medical knowledge alone, without any training data? Such classifiers normally require labelled images, which are costly and often unavailable. We investigate this question through weight-space programming (WSP), in which an LLM writes or adapts the weights and biases of a neural network directly, without optimisation on training data. Claude Opus 5.5 and GPT-6 Astra each generate the parameters of a small LeNet-style CNN in a single reply, without tool use and without access to any image. We compare these networks against zero-shot MedSigLIP and against the same architecture trained on labels using the Adam optimiser, across 7 classification tasks in four modalities: chest X-ray, breast ultrasound and abdominal CT (all from MedMNIST), and pelvic MRI (SynthUterus). The LLM-written networks perform above chance on all six MedMNIST tasks, with a mean test AUC of 0.719 for Opus and 0.711 for Astra. Both models outperform MedSigLIP on 5 of 6 tasks while using more than 10,000 times fewer parameters. However, the same network trained with Adam on only 256 labelled images achieves a higher AUC on every MedMNIST task (mean AUC 0.828). On SynthUterus, Opus attains an AUC of 0.764, whereas Astra falls below chance (AUC 0.136) owing to a systematic error. These results show that LLMs can write functional medical classifiers, but that they do not yet replace training data. We release the protocol, logs and all generated weights at https://github.com/MaximilianLindholz/weight-space-programming-medical.

cs.CV↗

Safeguarding Agentic AI in Radiology Workflows: A Multimodel Evaluation of Rule-based and Large Language Model-based Verification

Purpose: To estimate how often tool-using large language model (LLM) agents record clinically relevant false or unsupported information in simulated radiology documentation and how much safeguards applied before each action reduce these errors. Materials and Methods: In this simulation study (October 2026), 48 synthetic, radiologist-reviewed base scenarios covered finding communication, tumor board preparation and follow-up management. Forty-three also had a misleading-information variant (91 variants). Six LLM agents (Claude Sonnet 5.5, GPT-6.1-Sol, GLM-5.3, MiniMax M3, Gemma-4-31B, Qwen3.8-27B) completed each variant with permissions only, deterministic rules, and rules plus a locally run LLM checker (1638 episodes). The primary outcome was at least one executed high-severity violation per episode. Risk differences were estimated per agent at base-scenario level and, exploratorily, pooled across agents, with analyses of document access and blocks. Results: With permissions only, 7.3%-27.1% of episodes had a high-severity violation (pooled across agents, 19.4%). Pooled, it was 16.7% with rules (-2.8 percentage points; 95% CI: -6.1, 0.5) and 13.2% with rules plus the LLM checker (-6.2; 95% CI: -9.5, -3.0). Adding the LLM checker to rules changed it by -3.5 (95% CI: -6.3, -0.7). No difference between agents was detected (P = .43), and task success did not decrease detectably. In misleading variants, agents opened the altered document in 83% of episodes regardless of error, and 58% of erroneous statements cited it. Most blocked actions (64%-68%) would not have caused a violation and were returned for revision. Conclusion: Layered safeguards reduced but did not prevent high-severity errors. Errors after misleading information reflected misjudged rather than missed information.

cs.AI↗

Panda: Unsupervised Pelvic Anomaly Detection for Real-Time MR Imaging

Female pelvic diseases remain an under researched area characterized by often delayed diagnosis. While pelvic MRI offers superior soft-tissue contrast for diagnosis and image-guided procedures, real-time anomaly detection remains challenging due to physiological motion, tissue deformation, and instrument artifacts. Existing supervised approaches are impractical, as adverse events are rare, heterogeneous, and difficult to annotate. We present a Dinomaly-based unsupervised anomaly detection framework adapted for pelvic MRI that learns normative representations from healthy cases and flags deviations without requiring labels. Our approach leverages a frozen DINOv3 Vision Transformer encoder combined with a noisy MLP bottleneck and Linear Attention decoder to prevent identity mapping while maintaining computational efficiency. Anomalies are localized via per-token cosine distance between encoder and decoder representations, yielding spatial anomaly maps that provide immediate feedback at the scanner to support radiologist decision-making and adaptive protocol adjustment. Evaluated on a curated subset of the Uterine Myoma Dataset, the framework achieves a pixel-level AUROC of 88.06% and high specificity (95.45%) at frame level at 40.5 slices/s, meeting real-time clinical deployment requirements. The spatial anomaly maps and frame-level scores provide immediate, localized feedback at the scanner to support radiologist decision-making and adaptive protocol adjustment during active procedures.

cs.CV↗

PARROT: An Open Multilingual Radiology Reports Dataset

Rationale and Objectives: To develop and validate PARROT (Polyglottal Annotated Radiology Reports for Open Testing), a large, multicentric, open-access dataset of fictional radiology reports spanning multiple languages for testing natural language processing applications in radiology. Materials and Methods: From May to September 2024, radiologists were invited to contribute fictional radiology reports following their standard reporting practices. Contributors provided at least 20 reports with associated metadata including anatomical region, imaging modality, clinical context, and for non-English reports, English translations. All reports were assigned ICD-10 codes. A human vs. AI report differentiation study was conducted with 154 participants (radiologists, healthcare professionals, and non-healthcare professionals) assessing whether reports were human-authored or AI-generated. Results: The dataset comprises 2,658 radiology reports from 76 authors across 21 countries and 13 languages. Reports cover multiple imaging modalities (CT: 36.1%, MRI: 22.8%, radiography: 19.0%, ultrasound: 16.8%) and anatomical regions, with chest (19.9%), abdomen (18.6%), head (17.3%), and pelvis (14.1%) being most prevalent. In the differentiation study, participants achieved 53.9% accuracy (95% CI: 50.7%-57.1%) in distinguishing between human and AI-generated reports, with radiologists performing significantly better (56.9%, 95% CI: 53.3%-60.6%, p<0.05) than other groups. Conclusion: PARROT represents the largest open multilingual radiology report dataset, enabling development and validation of natural language processing applications across linguistic, geographic, and clinical boundaries without privacy constraints.

cs.CL↗