SearcharxivSearch

arXiv subjects

Mengting Fu

Publications and source records attributed to Mengting Fu.

At least 19 recordsLinked to original sources

Detecting Neutrinos from Supernova Bursts in PandaX-4T

Neutrinos from core-collapse supernovae are essential for the understanding of neutrino physics and stellar evolution. The dual-phase xenon dark matter detectors can provide a way to track explosions of galactic supernovae by detecting neutrinos through coherent elastic neutrino-nucleus scatterings. In this study, a variation of progenitor masses as well as explosion models are assumed to predict the neutrino fluxes and spectra, which result in the number of expected neutrino events ranging from 6.6 to 13.7 at a distance of 10 kpc over a 10-second duration with negligible backgrounds at PandaX-4T. Two specialized triggering alarms for monitoring supernova burst neutrinos are built. The efficiency of detecting supernova explosions at various distances in the Milky Way is estimated. These alarms will be implemented in the real-time supernova monitoring system at PandaX-4T in the near future, providing the astronomical communities with supernova early warnings.

hep-ex

Signal Response Model in PandaX-4T

PandaX-4T experiment is a deep-underground dark matter direct search experiment that employs a dual-phase time projection chamber with a sensitive volume containing 3.7 tonne of liquid xenon. The detector of PandaX-4T is capable of simultaneously collecting the primary scintillation and ionization signals, utilizing their ratio to discriminate dark matter signals from background sources such as gamma rays and beta particles. The signal response model plays a crucial role in interpreting the data obtained by PandaX-4T. It describes the conversion from the deposited energy by dark matter interactions to the detectable signals within the detector. The signal response model is utilized in various PandaX-4T results. This work provides a comprehensive description of the procedures involved in constructing and parameter-fitting the signal response model for the energy range of approximately 1 keV to 25 keV for electronic recoils and 6 keV to 90 keV for nuclear recoils. It also covers the signal reconstruction, selection, and correction methods, which are crucial components integrated into the signal response model.

physics.ins-det

Searching for Two-Neutrino and Neutrinoless Double Beta Decay of $^{134}$Xe with the PandaX-4T Experiment

$^{134}$Xe is a candidate isotope for neutrinoless double beta decay~($0\nu\beta\beta$) search. In addition, the two-neutrino case ($2\nu\beta\beta$) allowed by the Standard Model of particle physics has not yet been observed. Utilizing the 10.4% of $^{134}$Xe in the natural xenon in the PandaX-4T detector and its first 94.9-day exposure, we have established the most stringent constraints on $2\nu\beta\beta$ and $0\nu\beta\beta$ of $^{134}$Xe half-lives, with limits of $2.8\times10^{22}$ yr and $3.0\times10^{23}$ yr at 90% confidence level, respectively. The $2\nu\beta\beta$ ($0\nu\beta\beta$) limit surpasses the previously reported best result by a factor of 32 (2.7), highlighting the potential of large monolithic natural xenon detectors.

nucl-ex

Waveform Simulation in PandaX-4T

Signal reconstruction through software processing is a crucial component of the background and signal models in the PandaX-4T experiment, which is a multi-tonne dark matter direct search experiment. The accuracy of signal reconstruction is influenced by various detector artifacts, including noise, dark count of photomultiplier, impurity photoionization in the detector, and other relevant considerations. In this study, we present a detailed description of a semi-data-driven approach designed to simulate the signal waveform. This work provides a reliable model for the efficiency and bias of the signal reconstruction in the data analysis of PandaX-4T. By comparing critical variables which relate to the temporal shape and hit pattern of the signals, we demonstrate a good agreement between the simulation and data.

hep-ex

Search for Dark-Matter-Nucleon Interactions with a Dark Mediator in PandaX-4T

We report results of a search for dark-matter-nucleon interactions via a dark mediator using optimized low-energy data from the PandaX-4T liquid xenon experiment. With the ionization-signal-only data and utilizing the Migdal effect, we set the most stringent limits on the cross section for dark matter masses ranging from 30~$\rm{MeV/c^2}$ to 2~$\rm{GeV/c^2}$. Under the assumption that the dark mediator is a dark photon that decays into scalar dark matter pairs in the early Universe, we rule out significant parameter space of such thermal relic dark-matter model.

hep-ex

Search for light dark matter from atmosphere in PandaX-4T

We report a search for light dark matter produced through the cascading decay of $\eta$ mesons, which are created as a result of inelastic collisions between cosmic rays and Earth's atmosphere. We introduce a new and general framework, publicly accessible, designed to address boosted dark matter specifically, with which a full and dedicated simulation including both elastic and quasi-elastic processes of Earth attenuation effect on the dark matter particles arriving at the detector is performed. In the PandaX-4T commissioning data of 0.63 tonne$\cdot$year exposure, no significant excess over background is observed. The first constraints on the interaction between light dark matter generated in the atmosphere and nucleus through a light scalar mediator are obtained. The lowest excluded cross-section is set at $5.9 \times 10^{-37}{\rm cm^2}$ for dark matter mass of $0.1$ MeV$/c^2$ and mediator mass of 300 MeV$/c^2$. The lowest upper limit of $\eta$ to dark matter decay branching ratio is $1.6 \times 10^{-7}$.

hep-ex

Constraints on the axial-vector and pseudo-scalar mediated WIMP-nucleus interactions from PandaX-4T experiment

We present the constraints on the axial-vector and pseudo-scalar mediated WIMP-nucleus interactions from the PandaX-4T experiment, using the data set corresponding to a total exposure of 0.63~tonne$\cdot$year. No significant signal excess is observed, and the most stringent upper limits to date on the spin-dependent WIMP-neutron scattering cross section are set at 90\% confidence level with the minimum WIMP-neutron scattering cross section of 5.8$\times 10^{-42}$\si{\cm^{2}} for WIMP mass of 40~\si{\GeV/}$c^2$. Exclusion limits on the axial-vector and pseudo-scalar simplified models are also derived.

hep-ex

A First Search for Solar $^8$B Neutrino in the PandaX-4T Experiment using Neutrino-Nucleus Coherent Scattering

A search for interactions from solar $^8$B neutrinos elastically scattering off xenon nuclei using PandaX-4T commissioning data is reported. The energy threshold of this search is further lowered compared with the previous search for dark matter, with various techniques utilized to suppress the background that emerges from data with the lowered threshold. A blind analysis is performed on the data with an effective exposure of 0.48 tonne$\cdot$year, and no significant excess of events is observed. Among results obtained using the neutrino-nucleus coherent scattering, our results give the best constraint on the solar $^8$B neutrino flux. We further provide a more stringent limit on the cross section between dark matter and nucleon in the mass range from 3 to 9 GeV/c$^2$.

hep-ex

Neutron-induced nuclear recoil background in the PandaX-4T experiment

Neutron-induced nuclear recoil background is critical to the dark matter searches in the PandaX-4T liquid xenon experiment. This paper studies the feature of neutron background in liquid xenon and evaluates their contribution in the single scattering nuclear recoil events through three methods. The first method is fully Monte Carlo simulation based. The last two are data-driven methods that also use the multiple scattering signals and high energy signals in the data, respectively. In the PandaX-4T commissioning data with an exposure of 0.63 tonne-year, all these methods give a consistent result that there are $1.15\pm0.57$ neutron-induced background in dark matter signal region within an approximated nuclear recoil energy window between 5 and 100 keV.

hep-ex

A Search for Light Fermionic Dark Matter Absorption on Electrons in PandaX-4T

We report a search on a sub-MeV fermionic dark matter absorbed by electrons with an outgoing active neutrino using the 0.63 tonne-year exposure collected by PandaX-4T liquid xenon experiment. No significant signals are observed over the expected background. The data are interpreted into limits to the effective couplings between such dark matter and electrons. For axial-vector or vector interactions, our sensitivity is competitive in comparison to existing astrophysical bounds on the decay of such dark matter into photon final states. In particular, we present the first direct detection limits for an axial-vector (vector) interaction which are the strongest in the mass range from 25 to 45 (35 to 50) keV/c$^2$.

hep-ex

First search for the absorption of fermionic dark matter with the PandaX-4T experiment

Compared with the signature of dark matter elastic scattering off nuclei, the absorption of fermionic dark matter by nuclei opens up a new searching channel for light dark matter with a characteristic monoenergetic signal. In this Letter, we explore the $95.0$-day data from the PandaX-4T commissioning run and report the first dedicated searching results of the fermionic dark matter absorption signal through a neutral current process. No significant signal was found, and the lowest limit on the dark matter-nucleon interaction cross section is set to be $1.5\times10^{-50}$ cm$^2$ for a fermionic dark matter mass of $40$ MeV/$c^2$ with 90\% confidence level.

hep-ex

Measurement of Double Beta Decay Half-life of $^{136}$Xe with the PandaX-4T Detector

Precise measurement of two-neutrino double beta decay (DBD) half-life is an important step for the searches of Majorana neutrinos with neutrinoless double beta decay. We report the measurement of DBD half-life of $^{136}$Xe using the PandaX-4T dual-phase Time Projection Chamber (TPC) with 3.7-tonne natural xenon and the first 94.9-day physics data release. The background model in the fiducial volume is well constrained in situ by events in the outer active region. With a $^{136}$Xe exposure of 15.5 kg-year, we establish the half-life as $2.27 \pm 0.03 (stat.)\pm 0.10 (syst.)\times 10^{21}$ years. This is the first DBD half-life measurement with natural xenon and demonstrates the physics capability of a large-scale liquid xenon TPC in the field of rare event searches.

nucl-ex

A search for two-component Majorana dark matter in a simplified model using the full exposure data of PandaX-II experiment

In the two-component Majorana dark matter model, one dark matter particle can scatter off the target nuclei, and turn into a slightly heavier component. In the framework of a simplified model with a vector boson mediator, both the tree-level and loop-level processes contribute to the signal in direct detection experiment. In this paper, we report the search results for such dark matter from PandaX-II experiment, using total data of the full 100.7 tonne$\cdot$day exposure. No significant excess is observed, so strong constraints on the combined parameter space of mediator mass and dark matter mass are derived. With the complementary search results from collider experiments, a large range of parameter space can be excluded.

hep-ex

Study of background from accidental coincidence signals in the PandaX-II experiment

The PandaX-II experiment employed a 580kg liquid xenon detector to search for the interactions between dark matter particles and the target xenon atoms. The accidental coincidences of isolated signals result in a dangerous background which mimic the signature of the dark matter. We performed a detailed study on the accidental coincidence background in PandaX-II, including the possible origin of the isolated signals, the background level and corresponding background suppression method. With a boosted-decision-tree algorithm, the accidental coincidence background is reduced by 70% in the dark matter signal region, thus the sensitivity of dark matter search at PandaX-II is improved.

hep-ex

A Search for the Cosmic Ray Boosted Sub-GeV Dark Matter at the PandaX-II Experiment

We report a novel search for the cosmic ray boosted dark matter using the 100~tonne$\cdot$day full data set of the PandaX-II detector located at the China Jinping Underground Laboratory. With the extra energy gained from the cosmic rays, sub-GeV dark matter particles can produce visible recoil signals in the detector. The diurnal modulations in rate and energy spectrum are utilized to further enhance the signal sensitivity. Our result excludes the dark matter-nucleon elastic scattering cross section between 10$^{-31}$cm$^{2}$ and 10$^{-28}$cm$^{2}$ for a dark matter masses from 0.1 MeV/$c^2$ to 0.1 GeV/$c^2$, with a large parameter space previously unexplored by experimental collaborations.

hep-ex

Low Radioactive Material Screening and Background Control for the PandaX-4T Experiment

PandaX-4T is a ton-scale dark matter direct detection experiment using a dual-phase TPC technique at the China Jinping Underground Laboratory. Various ultra-low background technologies have been developed and applied to material screening for PandaX-4T, including HPGe gamma spectroscopy, ICP-MS, NAA, radon emanation measurement system, krypton assay station, and alpha detection system. Low background materials were selected to assemble the detector. Surface treatment procedures were investigated to further suppress radioactive background. Combining measured results and Monte Carlo simulation, the total material background rates of PandaX-4T in the energy region of 1-25 keV$\rm{}_{ee}$ are estimated to be (9.9 $\pm$ 1.9) $\times \ 10^{-3}$ mDRU for electron recoil and (2.8 $\pm$ 0.6) $\times \ 10^{-4}$ mDRU for nuclear recoil. In addition, $^{nat}$Kr in the detector is estimated to be <8 ppt.

physics.ins-det

Light yield and field dependence measurement in PandaX-II dual-phase xenon detector

The dual-phase xenon time projection chamber (TPC) is one of the most sensitive detector technology for dark matter direct search, where the energy deposition of incoming particle can be converted into photons and electrons through xenon excitation and ionization. The detector response to signal energy deposition varies significantly with the electric field in liquid xenon. We study the detector's light yield and its dependence on the electric field in the PandaX-II dual-phase detector containing 580~kg liquid xenon in the sensitive volume. From our measurements, the light yield at electric fields from 0~V/cm to 317~V/cm is obtained for energy depositions up to 236~keV.

physics.ins-det

Dark Matter Search Results from the PandaX-4T Commissioning Run

We report the first dark matter search results using the commissioning data from PandaX-4T. Using a time projection chamber with 3.7-tonne of liquid xenon target and an exposure of 0.63 tonne$\cdot$year, 1058 candidate events are identified within an approximate nuclear recoil energy window between 5 and 100 keV. No significant excess over background is observed. Our data set a stringent limit to the dark matter-nucleon spin-independent interactions, with a lowest excluded cross section (90% C.L.) of $3.8\times10^{-47} $cm$^2$ at a dark matter mass of 30 GeV/$c^2$.

hep-ex