SearcharxivSearch

arXiv subjects

Michael Atlan

Publications and source records attributed to Michael Atlan.

At least 37 records · Page 2Linked to original sources

Singular value demodulation of phase-shifted holograms

We report on phase-shifted holographic interferogram demodulation by singular value decomposition. Numerical processing of optically-acquired interferograms over several modulation periods was performed in two steps : 1- rendering of off-axis complex-valued holograms by Fresnel transformation of the interferograms; 2- eigenvalue spectrum assessment of the lag-covariance matrix of hologram pixels. Experimental results in low-light recording conditions were compared with demodulation by Fourier analysis, in the presence of random phase drifts.

physics.optics

Holographic laser Doppler imaging of pulsatile blood flow

We report on wide-field imaging of pulsatile motion induced by blood flow using heterodyne holographic interferometry on the thumb of a healthy volunteer, in real-time. Optical Doppler images were measured with green laser light by a frequency-shifted Mach-Zehnder interferometer in off-axis configuration. The recorded optical signal was linked to local instantaneous out-of-plane motion of the skin at velocities of a few hundreds of microns per second, and compared to blood pulse monitored by plethysmoraphy during an occlusion-reperfusion experiment.

physics.optics

Holographic imaging of surface acoustic waves

We report on an experimental demonstration of surface acoustic waves monitoring on a thin metal plate with heterodyne optical holography. Narrowband imaging of local optical pathlength modulation is achieved with a frequency-tunable time-averaged laser Doppler holographic imaging scheme on a sensor array, at video-rate. This method enables robust and quantitative mapping of out-of-plane vibrations of nanometric amplitudes at radiofrequencies.

physics.optics

Non-destructive testing of composite plates by holographic vibrometry

We report on a wide-field optical monitoring method for revealing local delaminations in sandwich-type composite plates at video-rate by holographic vibrometry. Non-contact measurements of low frequency flexural waves is performed with time-averaged heterodyne holography. It enables narrowband imaging of local out-of-plane nanometric vibration amplitudes under sinusoidal excitation, and reveals delamination defects, which cause local resonances of flexural waves. The size of the defect can be estimated from the first resonance frequency of the flexural wave and the mechanical parameters of the observed layer of the composite plate.

physics.optics

Video-rate computational heterodyne holography

We present a versatile computational image rendering software of optically-acquired holograms. The reported software can process 4 Megapixel 8-bit raw frames from a sensor array acquired at a sustained rate of 80 Hz. Video-rate image rendering is achieved by streamline image processing with commodity computer graphics hardware. For time-averaged holograms acquired in off-axis optical configuration with a frequency-shifted reference beam, wide-field imaging of one tunable spectral component is permitted. This software is validated by phase-stepped hologram rendering, and non-contact monitoring of surface acoustic waves by single and dual sideband hologram rendering. It demonstrates the suitability of holography for video-rate computational laser Doppler imaging in heterodyne optical configuration.

physics.optics

Phase-sensitive narrowband heterodyne holography

We report on amplitude and phase imaging of out-of-plane sinusoidal surface vibration at nanometer scales with a heterodyne holographic interferometer. The originality of the proposed method is to make use of a multiplexed local oscillator to address several optical sidebands into the temporal bandwidth of a sensor array. This process is called coherent frequency-division multiplexing. It enables simultaneous recording and pixel-to-pixel division of sideband holograms, which permits quantitative wide-field mapping of optical phase modulation depths. Additionally, a linear frequency chirp ensures the retrieval of the local mechanical phase shift of the vibration with respect to the excitation signal. The proposed approach is validated by quantitative motion characterization of the lamellophone of a musical box, behaving as a group of harmonic oscillators, under weak sinusoidal excitation. Images of the vibration amplitude versus excitation frequency show the resonance of the nanometric flexural response of one individual cantilever, at which a phase hop is measured. ©Optical Society of America.

physics.optics

Laser Doppler Imaging of Microflow

We report a pilot study with a wide-field laser Doppler detection scheme used to perform laser Doppler anemometry and imaging of particle seeded microflow. The optical field carrying the local scatterers (particles) dynamic state, as a consequence of momentum transfer at each scattering event, is analyzed in the temporal frequencies domain. The setup is based on heterodyne digital holography, which is used to map the scattered field in the object plane at a tunable frequency with a multipixel detector. We show that wide-field heterodyne laser Doppler imaging can be used for quantitative microflow diagnosis; in the presented study, maps of the first-order moment of the Doppler frequency shift are used as a quantitative and directional estimator of the Doppler signature of particles velocity.

physics.optics

Vibration motions studied by Heterodyne Holography

Playing with amplitude, phase and frequency of both reference and signal arms, heterodyne holography is well adapted to vibration analysis. Vibration sidebands can be imaged and stroboscopic measurement sensitive to mechanical phase can be made

physics.optics

Signal and Noise scaling factors in digital holography

An experimental study on how reconstructed image signal and noise scale with acquisition and reconstruction parameters is proposed. Monte-carlo simulation is performed to emphasize that the measured noise is shot-noise.

physics.optics

Short-time Fourier transform laser Doppler holography

We report a demonstration of laser Doppler holography at a sustained acquisition rate of 250 Hz on a 1 Megapixel complementary metal-oxide-semiconductor (CMOS) sensor array and image display at 10 Hz frame rate. The holograms are optically acquired in off-axis configuration, with a frequency-shifted reference beam. Wide-field imaging of optical fluctuations in a 250 Hz frequency band is achieved by turning time-domain samplings to the dual domain via short-time temporal Fourier transformation. The measurement band can be positioned freely within the low radio-frequency spectrum by tuning the frequency of the reference beam in real-time. Video-rate image rendering is achieved by streamline image processing with commodity computer graphics hardware. This experimental scheme is validated by a non-contact vibrometry experiment.

physics.optics

Phase-resolved heterodyne holographic vibrometry with a strobe local oscillator

We report a demonstration of phase-resolved vibrometry, in which out-of-plane sinusoidal motion is assessed by heterodyne holography. In heterodyne holography, the beam in the reference channel is an optical local oscillator (LO). It is frequency-shifted with respect to the illumination beam to enable frequency conversion within the sensor bandwidth. The proposed scheme introduces a strobe LO, where the reference beam is frequency-shifted and modulated in amplitude, to alleviate the issue of phase retrieval. The strobe LO is both tuned around the first optical modulation side band at the vibration frequency, and modulated in amplitude to freeze selected mechanical vibration states sequentially. The phase map of the vibration can then be derived from the demodulation of successive vibration states.

physics.optics

Absolute measurement of small-amplitude vibrations by time-averaged heterodyne holography with a dual local oscillator

We report a demonstration of the measurement of the ratio between an optical modulation side band component and the non-shifted light component by time-averaged heterodyne holography in off-axis and frequency-shifting configuration, through coherent frequency-division multiplexing with a dual optical local oscillator. Experimental results of sinusoidal vibration sensing are reported. This technique enables absolute measurements of sub-nanometric out-of-plane vibration amplitudes.

physics.optics

Imaging velocities of a vibrating object by stroboscopic sideband holography

We propose here to combine sideband holography with stroboscopic illumination synchronized with the vibration of an object. By sweeping the optical frequency of the reference beam such a way the holographic detection is tuned on the successive sideband harmonic ranks, we are able to image the instantaneous velocities of the object. Since the stroboscopic illumination is made with an electronic device, the method is compatible with fast (up to several MHz) vibration motions. The method is demonstrated with a vibrating clarinet reed excited sinusoidally at 2 kHz, and a stroboscopic illumination with cyclic ratio 0.15. Harmonic rank up to n = $\pm$100 are detected, and a movie of the instantaneous velocities is reported.

physics.optics

Shot Noise in Digital Holography

We discuss on noise in heterodyne holography in an off-axis configuration. We show that, for a weak signal, the noise is dominated by the shot noise on the reference beam. This noise corresponds to an equivalent noise on the signal beam of one photoelectron per pixel, for the whole sequence of images used to build the digital hologram.

physics.optics

Digital Holography at Shot Noise Level

By a proper arrangement of a digital holography setup, that combines off-axis geometry with phase-shifting recording conditions, it is possible to reach the theoretical shot noise limit, in real-time experiments.We studied this limit, and we show that it corresponds to 1 photo-electron per pixel within the whole frame sequence that is used to reconstruct the holographic image. We also show that Monte Carlo noise synthesis onto holograms measured at high illumination levels enables accurate representation of the experimental holograms measured at very weak illumination levels. An experimental validation of these results is done.

physics.optics

Exploring shot noise and Laser Doppler imagery with heterodyne holography

Heterodyne Holography is a variant of Digital Holography, where the optical frequencies of signal and reference arms can be freely adjusted by acousto-optic modulators. Heterodyne Holography is an extremely versatile and reliable holographic technique, which is able the reach the shot noise limit in sensitivity at very low levels of signal. Frequency tuning enables Heterodyne Holography to become a Laser Doppler imaging technique that is able to analyze various kinds of motion.

physics.optics

3D exploration of light scattering from live cells in the presence of gold nanomarkers using holographic microscopy

In this paper, we explore the 3D structure of light scattering from dark-field illuminated live 3T3 cells in the presence of 40 nm gold nanomarkers. For this purpose, we use a high resolution holographic microscope combining the off-axis heterodyne geometry and the phase-shifting acquisition of the digital holograms. A comparative study of the 3D reconstructions of the scattered fields allows us to locate the gold markers which yield, contrarily to the cell structures, well defined bright scattering patterns that are not angularly titled and clearly located along the optical axis (z). This characterization is an unambiguous signature of the presence of gold biological nanomarkers, and validates the capability of digital holographic microscopy to discriminate them from background signals in live ce

physics.optics

Off-axis digital hologram reconstruction: some practical considerations

Holographic rendering of off-axis intensity digital holograms is discussed. A review of some of the main numerical processing methods, based either on the Fourier transform interpretation of the propagation integral or on its linear system counterpart, is reported. Less common methods such as adjustable magnification reconstruction schemes and Fresnelet decomposition are presented and applied to the digital treatment of off-axis holograms. The influence of experimental parameters on the classical hologram reconstruction methods is assessed, offering guidelines for optimal image rendering regarding the hologram recording conditions.

physics.optics