SearcharxivSearch

arXiv subjects

Michael Sturm

Publications and source records attributed to Michael Sturm.

9 recordsLinked to original sources

First results of the Tritium Absorption InfraRed Spectroscopy (T2ApIR) experiment

The literature on experimentally verified material properties of tritium is sparse but information about this is crucial in fusion for pellet production (Magnetic Confined Fusion), target fueling (Inertial Confined Fusion), cryogenic distillation, as well as in astroparticle physics for neutrino experiments, and search for rare physics. To improve on this, the T$_2$ApIR experiment has been designed and built at the Tritium Laboratory Karlsruhe (TLK), and is in its scientific commissioning phase. The main focus of this experiment is to enable the investigation of the properties of all six hydrogen isotopologues and their mixtures in the gaseous, liquid, and solid phase, as well as the dynamics of their phase changes. In addition, mixtures with noble gases such as xenon and neon can be investigated. This is achieved using a cryogenic setup capable of reaching less than 10 in a measurement cell that allows optical access for infrared absorption spectroscopy, Raman spectroscopy and a polariscope setup, as well as temperature and pressure measurement.

physics.ins-det

Commissioning of an experiment for thermodynamic and spectroscopic studies of hydrogen isotopologues at cryogenic conditions

To study thermodynamic properties and dynamic phase space behavior of hydrogen isotopologues (Q$_2$) at cryogenic temperatures and at high density, the Tritium Absorption InfraRed Spectroscopy 2 (T$_2$ApIR) experiment has been set up and commissioned at Tritium Laboratory Karlsruhe (TLK). In the frame of the experiment, Q$_2$ behavior in different phases, ortho/para states, temperatures (10 K - 300 K) and pressures (up to 2.5 bar a) will be investigated with optical methods, infrared and Raman spectroscopy. The facility consists of a fully tritium compatible cryostat, which includes an optical cell, ortho/para converter and windows for optical and spectroscopic studies. The cryostat can be cooled below the H$_2$ triple point by a two-stage cryocooler and contains openings in the cryogenic shielding for the optical access. The challenge of combining these scientific requirements in a design with high amounts of tritium (14 g), in a limited space, all while maintaining the TLK safety philosophy was solved by the presented design. The experiment is ready to be fully integrated into the TLK closed loop tritium infrastructure. This contribution reports a comprehensive overview of the commissioning phase of the experimental facility and the results of the first commissioning experiments, including cryogenic performance tests, commissioning experiments with non-radioactive gases, and tests of the analytical instruments.

cond-mat.stat-mech

ViMA -- the spinning rotor gauge to measure the viscosity of tritium between 77 and 300 K

Experimental values for the viscosity of the radioactive hydrogen isotope tritium (T$_2$) are currently unavailable in literature. The value of this material property over a wide temperature range is of interest for applications in the field of fusion, neutrino physics, as well as to test ab initio calculations. As a radioactive gas, tritium requires careful experiment design to ensure safe and environmental contamination free measurements. In this contribution, we present a spinning rotor gauge based, tritium compatible design of a gas viscosity measurement apparatus (ViMA) capable of covering the temperature range from 80 K to 300 K.

physics.ins-det

Viscosity measurements of gaseous H2 between 200 K to 300 K with a spinning rotor gauge

Experimental values for the viscosity of the radioactive hydrogen isotopologue tritium are still unknown in literature. Existing values from ab initio calculations disregard quantum mechanic effects and are therefore only good approximations for room temperature and above. To fill in these missing experimental values, a measurement setup has been designed, to measure the viscosity of gaseous hydrogen and its isotopologues (H$_2$, HD, HT, D$_2$, DT, T$_2$) at cryogenic temperatures. In this paper, the first results with this Cryogenic Viscosity Measurement Apparatus (Cryo-ViMA) of the viscosity of gaseous hydrogen between 200 K to 300 K are presented.

physics.ins-det

Operation Modes of the KATRIN Experiment Tritium Loop System using $^{83\mathrm{m}}$Kr

The KArlsruhe TRItium Neutrino (KATRIN) experiment aims to search for the effective electron antineutrino mass with a sensitivity of 0.2 eV (90 % C.L.). In order to achieve this goal, KATRIN measurement phases focusing on the neutrino mass search are alternated with phases of investigations of systematic effects. During these phases, metastable $^{83\mathrm{m}}$Kr is used as a calibration source. The monoenergetic conversion electrons emitted accompanying the decay of $^{83\mathrm{m}}$Kr allow a direct access to the starting conditions of $\beta$-electrons produced inside the windowless gaseous tritium source (WGTS) of KATRIN. To make use of $^{83\mathrm{m}}$Kr in the WGTS, the Tritium Loop System, which provides a stable flow of tritium to the WGTS, needs to be operated in special modes. This paper focuses on the technical implementation of these modes and their performance with regard to the achievable $^{83\mathrm{m}}$Kr-rates, gas densities, and gas compositions inside the WGTS.

physics.ins-det

Neutral tritium gas reduction in the KATRIN differential pumping sections

The KArlsruhe TRItium Neutrino experiment (KATRIN) aims to measure the effective electron anti-neutrino mass with an unprecedented sensitivity of $0.2\,\mathrm{eV}/\mathrm{c}^2$, using $β$-electrons from tritium decay. The electrons are guided magnetically by a system of superconducting magnets through a vacuum beamline from the windowless gaseous tritium source through differential and cryogenic pumping sections to a high resolution spectrometer and a segmented silicon pin detector. At the same time tritium gas has to be prevented from entering the spectrometer. Therefore, the pumping sections have to reduce the tritium flow by more than 14 orders of magnitude. This paper describes the measurement of the reduction factor of the differential pumping section performed with high purity tritium gas during the first measurement campaigns of the KATRIN experiment. The reduction factor results are compared with previously performed simulations, as well as the stringent requirements of the KATRIN experiment.

physics.ins-det

The PanEDM Neutron Electric Dipole Moment Experiment at the ILL

The neutron's permanent electric dipole moment $d_n$ is constrained to below $3\times10^{-26} e~\text{cm}$ (90% C.L.) [ arXiv:hep-ex/0602020, arXiv:1509.04411 ], by experiments using ultracold neutrons (UCN). We plan to improve this limit by an order of magnitude or more with PanEDM, the first experiment exploiting the ILL's new UCN source SuperSUN. SuperSUN is expected to provide a high density of UCN with energies below 80 neV, implying extended statistical reach with respect to existing sources, for experiments that rely on long storage or spin-precession times. Systematic errors in PanEDM are strongly suppressed by passive magnetic shielding, with magnetic field and gradient drifts at the single fT level. A holding-field homogeneity on the order of $10^{-4}$ is achieved in low residual fields, via a high static damping factor and built-in coil system. No comagnetometer is needed for the first order-of-magnitude improvement in $d_n$, thanks to high magnetic stability and an assortment of sensors outside the UCN storage volumes. PanEDM will be commissioned and upgraded in parallel with SuperSUN, to take full advantage of the source's output in each phase. Commissioning is ongoing in 2019, and a new limit in the mid $10^{-27} e~\text{cm}$ range should be possible with two full reactor cycles of data in the commissioned apparatus.

physics.ins-det

Monitoring of tritium purity during long-term circulation in the KATRIN test experiment LOOPINO using laser Raman spectroscopy

The gas circulation loop LOOPINO has been set up and commissioned at Tritium Laboratory Karlsruhe (TLK) to perform Raman measurements of circulating tritium mixtures under conditions similar to the inner loop system of the neutrino-mass experiment KATRIN, which is currently under construction. A custom-made interface is used to connect the tritium containing measurement cell, located inside a glove box, with the Raman setup standing on the outside. A tritium sample (purity > 95%, 20 kPa total pressure) was circulated in LOOPINO for more than three weeks with a total throughput of 770 g of tritium. Compositional changes in the sample and the formation of tritiated and deuterated methanes CT_(4-n)X_n (X=H,D; n=0,1) were observed. Both effects are caused by hydrogen isotope exchange reactions and gas-wall interactions, due to tritium β decay. A precision of 0.1% was achieved for the monitoring of the T_2 Q_1-branch, which fulfills the requirements for the KATRIN experiment and demonstrates the feasibility of high-precision Raman measurements with tritium inside a glove box.

physics.ins-det

Status of the KATRIN experiment with special emphasis on source-related issues

The Karlsruhe Tritium Neutrino experiment KATRIN will allow a model independent measurement of the neutrino mass scale with an expected sensitivity of 0.2 eV/c^{2} (90% C.L.) and so will help to clarify the role of neutrinos in the early universe is the direct measurement of the mass of the electron anti-neutrino. KATRIN investigates spectroscopically the electron spectrum from tritium beta- decay close to the kinematic endpoint of 18.6 keV with a high resolution electro-static filter of unprecedented energy resolution of 0.93 eV. KATRIN will be built at the Tritium Laboratory Karlsruhe on site of the KIT Campus North. For such a precise mass-determination a key parameter is the stability of the source in terms of beta-activity und isotopic purity. For that purpose KATRIN uses a strong windowless gaseous tritium source of almost pure molecular tritium (95%) with a throughput of 40 g tritium per day stabilized on 0.1% level. The decay electrons are guided adiabatically from the source to the spectrometer by means of superconducting magnets while at the same time the tritium flow rate to the spectrometers has to be reduced by a factor > 1E14. To reach the sensitivity KATRIN is aiming for, an high energy resolution as well as high statistics and low background are needed. A tandem spectrometer system is used for energy analysis. The transport section consists of a differential pumping system (DPS2-F) and a cryogenic pumping section (CPS). In the DPS2-F the tritium flow will be reduced by differential pumping while in the CPS tritium will be adsorbed on a pre-condensed argon layer prepared inside KATRIN's beamtube. To assure the required stability of the source on 0.1% level a stabilized tritium injection in the source is required. This is done by closed tritium loops. The purity and composition of the injected gas will be monitored by Laser Raman spectroscopy.

hep-ex