SearcharxivSearch

arXiv · 1911.09161

The PanEDM Neutron Electric Dipole Moment Experiment at the ILL

Abstract

The neutron's permanent electric dipole moment $d_n$ is constrained to below $3\times10^{-26} e~\text{cm}$ (90% C.L.) [ arXiv:hep-ex/0602020, arXiv:1509.04411 ], by experiments using ultracold neutrons (UCN). We plan to improve this limit by an order of magnitude or more with PanEDM, the first experiment exploiting the ILL's new UCN source SuperSUN. SuperSUN is expected to provide a high density of UCN with energies below 80 neV, implying extended statistical reach with respect to existing sources, for experiments that rely on long storage or spin-precession times. Systematic errors in PanEDM are strongly suppressed by passive magnetic shielding, with magnetic field and gradient drifts at the single fT level. A holding-field homogeneity on the order of $10^{-4}$ is achieved in low residual fields, via a high static damping factor and built-in coil system. No comagnetometer is needed for the first order-of-magnitude improvement in $d_n$, thanks to high magnetic stability and an assortment of sensors outside the UCN storage volumes. PanEDM will be commissioned and upgraded in parallel with SuperSUN, to take full advantage of the source's output in each phase. Commissioning is ongoing in 2019, and a new limit in the mid $10^{-27} e~\text{cm}$ range should be possible with two full reactor cycles of data in the commissioned apparatus.

Explore related subjects

Keep this discovery

BibTeXRIS

David Wurm, Douglas H. Beck, Tim Chupp, Skyler Degenkolb, Katharina Fierlinger, Peter Fierlinger, Hanno Filter, Sergey Ivanov, Christopher Klau, Michael Kreuz, Eddy Lelièvre-Berna, Tobias Lins, Joachim Meichelböck, Thomas Neulinger, Robert Paddock, Florian Röhrer, Martin Rosner, Anatolii P. Serebrov, Jaideep Taggart Singh, Rainer Stoepler, Stefan Stuiber, Michael Sturm, Bernd Taubenheim, Xavier Tonon, Mark Tucker, Maurits van der Grinten, Oliver Zimmer. 2019-11-20. The PanEDM Neutron Electric Dipole Moment Experiment at the ILL. https://doi.org/10.1051/epjconf/201921902006

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det