SearcharxivSearch

arXiv subjects

Michel Gross

Publications and source records attributed to Michel Gross.

At least 19 recordsLinked to original sources

Floating-point consistent cross-verification methodology for reproducible and interoperable DDA solvers with fair benchmarking

The discrete dipole approximation (DDA) is a widely used and versatile numerical method for solving electromagnetic scattering by arbitrarily shaped objects. Despite its popularity, quantitative comparisons between independent implementations remain challenging due to differences in linear-system conventions, solver settings, and default numerical parameters. In this work, we introduce a unified software-assisted methodology for cross-verification and benchmarking of three major open-source DDA solvers: DDSCAT, ADDA, and IFDDA. We demonstrate how machine-precision agreement can be achieved across implementations by aligning all free parameters and provide practical equivalence tables enabling reproducible and interoperable simulations. Using this methodology, we perform systematic CPU and GPU performance comparisons covering OpenMP, MPI, and CUDA/OpenCL parallelization. Beyond benchmarking, our approach serves as a practical guide for configuring consistent DDA simulations and for understanding how precision, solver choice, and hardware architecture affect runtime, scalability, and accuracy in computational light-scattering studies. The software package also supports regression testing and bitwise reproducibility verification for future code releases.

physics.comp-ph

High numerical aperture holographic microscopy reconstruction with extended z range

An holographic microscopy reconstruction method compatible with high numerical aperture microscope objective (MO) up to NA=1.4 is proposed. After off axis and reference field curvature corrections, and after selection of the +1 grating order holographic image, a phase mask that transforms the optical elements of the holographic setup into an afocal device is applied in the camera plane. The reconstruction is then made by the angular spectrum method. The field is first propagated in the image half space from the camera to the afocal image of the MO optimal plane (plane for which MO has been designed) by using a quadratic kernel. The field is then propagated from the MO optimal plane to the object with the exact kernel. Calibration of the reconstruction is made by imaging a calibrated object like an USAF resolution target for different positions along $z$. Once the calibration is done, the reconstruction can be made with an object located in any plane $z$. The reconstruction method has been validated experimentally with an USAF target imaged with a NA=1.4 microscope objective. Near-optimal resolution is obtained over an extended range ($\pm 50~μ$m) of $z$ locations.

physics.optics

Heterodyne Holography with full control of both signal and reference arms

Heterodyne holography is a variant of phase shifting holography in which reference and signal arms are controlled by acousto optic modulators. In this review paper, we will briefy describe the method and its properties, and we will illustrate its advantages in experimental applications.

physics.optics

Holographic vibrometry: Full field holographic vibrometry at ultimate limits

Heterodyne holography is an extremely versatile and powerful holographic technique that is able to fully control the amplitude, phase and frequency of both the illumination and holographic reference beams. Applied to vibration analysis, this technique is able to detect the signal of the carrier or the one of any vibration sideband. A complete analysis of the vibration signal can thus be made, and 2D map of the vibration amplitude and phase in all points of the surface of the vibrating object can be obtained. Since the sensitivity is limited by shot noise, extremely low vibration amplitude (\textless{} 0.01 nm) can be studied.

physics.optics

Holographic microscopy reconstruction in both object and image half spaces with undistorted 3D grid

We propose an holographic microscopy reconstruction method, which propagates the hologram, in the object half space, in the vicinity of the object. The calibration yields reconstructions with an undistorted reconstruction grid i.e. with orthogonal $x$, $y$ and $z$ axis and constant pixels pitch. The method is validated with an USAF target imaged by a $\times$60 microscope objective, whose holograms are recorded and reconstructed for different USAF locations along the longitudinal axis: -75 to +75 $μ$m. Since the reconstruction numerical phase mask, the reference phase curvature and MO form an afocal device, the reconstruction can be interpreted as occurring equivalently in the object or in image half space.

physics.optics

Statistical Estimation of Mechanical Parameters of Clarinet Reeds Using Experimental and Numerical Approaches

A set of 55 clarinet reeds is observed by holography, collecting 2 series of measurements made under 2 different moisture contents, from which the resonance frequencies of the 15 first modes are deduced. A statistical analysis of the results reveals good correlations, but also significant differences between both series. Within a given series, flexural modes are not strongly correlated. A Principal Component Analysis (PCA) shows that the measurements of each series can be described with 3 factors capturing more than $90\%$ of the variance: the first is linked with transverse modes, the second with flexural modes of high order and the third with the first flexural mode. A forth factor is necessary to take into account the individual sensitivity to moisture content. Numerical 3D simulations are conducted by Finite Element Method, based on a given reed shape and an orthotropic model. A sensitivity analysis revels that, besides the density, the theoretical frequencies depend mainly on 2 parameters: $E_L$ and $G_{LT}$. An approximate analytical formula is proposed to calculate the resonance frequencies as a function of these 2 parameters. The discrepancy between the observed frequencies and those calculated with the analytical formula suggests that the elastic moduli of the measured reeds are frequency dependent. A viscoelastic model is then developed, whose parameters are computed as a linear combination from 4 orthogonal components, using a standard least squares fitting procedure and leading to an objective characterization of the material properties of the cane \textit{Arundo donax}.

physics.class-ph

Laser Doppler holographic microscopy in transmission: application to fish embryo imaging

We have extended Laser Doppler holographic microscopy to transmission geometry. The technique is validated with living fish embryos imaged by a modified upright bio-microcope. By varying the frequency of the holographic reference beam, and the combination of frames used to calculate the hologram, multimodal imaging has been performed. Doppler images of the blood vessels for different Doppler shifts, images where the flow direction is coded in RGB colors or movies showing blood cells individual motion have been obtained as well. The ability to select the Fourier space zone that is used to calculate the signal, makes the method quantitative.

physics.optics

Laser Doppler Imaging of Microflow

We report a pilot study with a wide-field laser Doppler detection scheme used to perform laser Doppler anemometry and imaging of particle seeded microflow. The optical field carrying the local scatterers (particles) dynamic state, as a consequence of momentum transfer at each scattering event, is analyzed in the temporal frequencies domain. The setup is based on heterodyne digital holography, which is used to map the scattered field in the object plane at a tunable frequency with a multipixel detector. We show that wide-field heterodyne laser Doppler imaging can be used for quantitative microflow diagnosis; in the presented study, maps of the first-order moment of the Doppler frequency shift are used as a quantitative and directional estimator of the Doppler signature of particles velocity.

physics.optics

Vibration motions studied by Heterodyne Holography

Playing with amplitude, phase and frequency of both reference and signal arms, heterodyne holography is well adapted to vibration analysis. Vibration sidebands can be imaged and stroboscopic measurement sensitive to mechanical phase can be made

physics.optics

Signal and Noise scaling factors in digital holography

An experimental study on how reconstructed image signal and noise scale with acquisition and reconstruction parameters is proposed. Monte-carlo simulation is performed to emphasize that the measured noise is shot-noise.

physics.optics

Experimental study of z resolution in acousto-optical coherence tomography using random phase jumps on ultrasound and light

Acousto-Optical Coherence Tomography (AOCT) is a variant of Acousto Optic Imaging (also called Ultrasound modulated Optical Tomography) that makes possible to get resolution along the ultrasound propagation axis $z$. We present here new AOCT experimental results, and we study how the $z$ resolution depends on time step between phase jumps $T_ϕ$, or on the correlation length $Δz$. By working at low resolution, we perform a quantitative comparison of the $z$ measurements with the theoretical Point Spread Function (PSF). We present also images recorded with different $z$ resolution, and we qualitatively show how the image quality varies with $T_ϕ$, or $Δz$.

physics.optics

Phase-resolved heterodyne holographic vibrometry with a strobe local oscillator

We report a demonstration of phase-resolved vibrometry, in which out-of-plane sinusoidal motion is assessed by heterodyne holography. In heterodyne holography, the beam in the reference channel is an optical local oscillator (LO). It is frequency-shifted with respect to the illumination beam to enable frequency conversion within the sensor bandwidth. The proposed scheme introduces a strobe LO, where the reference beam is frequency-shifted and modulated in amplitude, to alleviate the issue of phase retrieval. The strobe LO is both tuned around the first optical modulation side band at the vibration frequency, and modulated in amplitude to freeze selected mechanical vibration states sequentially. The phase map of the vibration can then be derived from the demodulation of successive vibration states.

physics.optics

(DH) Noise and Signal scaling factors in Digital Holography in week illumination: relationship with Shot Noise

We have performed off axis heterodyne holography with very weak illumination by recording holograms of the object with and without object illumination in the same acquisition run. We have experimentally studied, how the reconstructed image signal (with illumination) and noise background (without) scale with the holographic acquisition and reconstruction parameters that are the number of frames, and the number of pixels of the reconstruction spatial filter. The first parameter is related to the frequency bandwidth of detection in time, the second one to the bandwidth in space. The signal to background ratio varies roughly like the inverse of the bandwidth in time and space. We have also compared the noise background with the theoretical shot noise background calculated by Monte Carlo simulation. The experimental and Monte Carlo noise background agree very well together.

physics.optics

Holographic microscopy for the three-dimensional exploration of light scattering from gold nanomarkers in biological media

The 3D structure of light scattering from dark-field illuminated live 3T3 cells marked with 40 nm gold nanomarkers is explored. For this purpose, we use a high resolution holographic microscope combining the off-axis heterodyne geometry and the phase-shifting acquisition of the digital holograms. Images are obtained using a novel 3D reconstruction method providing longitudinally undistorted 3D images. A comparative study of the 3D reconstructions of the scattered fields allows us to locate the gold markers which yield, contrarily to the cellular structures, well defined bright scattering patterns that are not angularly titled and clearly located along the optical axis. This characterization is an unambiguous signature of the presence of the gold biological nanomarkers, and validates the capability of digital holographic microscopy to discriminate them from background signals in live cells.

physics.optics

Three dimensional tracking of gold nanoparticles using digital holographic microscopy

In this paper we present a digital holographic microscope to track gold colloids in three dimensions. We report observations of 100nm gold particles in motion in water. The expected signal and the chosen method of reconstruction are described. We also discuss about how to implement the numerical calculation to reach real-time 3D tracking.

physics.optics

Imaging velocities of a vibrating object by stroboscopic sideband holography

We propose here to combine sideband holography with stroboscopic illumination synchronized with the vibration of an object. By sweeping the optical frequency of the reference beam such a way the holographic detection is tuned on the successive sideband harmonic ranks, we are able to image the instantaneous velocities of the object. Since the stroboscopic illumination is made with an electronic device, the method is compatible with fast (up to several MHz) vibration motions. The method is demonstrated with a vibrating clarinet reed excited sinusoidally at 2 kHz, and a stroboscopic illumination with cyclic ratio 0.15. Harmonic rank up to n = $\pm$100 are detected, and a movie of the instantaneous velocities is reported.

physics.optics