SearcharxivSearch

arXiv subjects

Mukul Sholapurkar

Publications and source records attributed to Mukul Sholapurkar.

13 recordsLinked to original sources

Adiabatic response in the Migdal Effect

The Migdal effect-the prompt ionization induced by a sudden nuclear recoil-is widely used in direct dark matter searches, yet its validity beyond the impulse approximation has remained unresolved. We present the first first-principles calculation for isolated atoms, establishing the adiabatic crossover where ionization is suppressed. We show that this behavior is fully encoded in the scattering amplitude, without ad hoc assumptions, and map the relevant parameter space, finding that dark matter searches lie in the unsuppressed regime.

hep-ph

Detectability of dark matter subhalo impacts in Milky Way stellar streams

Stellar streams are a promising way to probe the gravitational effects of low-mass dark matter (DM) subhalos. In recent years, there has been a remarkable explosion in the number of stellar streams detected in the Milky Way, and hundreds more may be discovered with future surveys such as LSST. Studies of DM subhalo impacts on streams have so far focused on a few of the thinnest and brightest streams, and it is not known how much information can be gained from the others. In this work, we develop a method to quickly estimate the minimum detectable DM subhalo mass of a given stream, depending on its width, length, distance, and stellar density. We use an analytic model for the impacts and apply a test statistic to determine whether they are detectable. We consider several observational scenarios, based on current and future surveys including Gaia, DESI, Via, and LSST. We find that at 95% confidence level, a stream like GD-1 has a minimum detectable subhalo mass of $\sim 6\times 10^6~\mathrm{M}_\odot$ in Gaia data and $\sim 8\times 10^5~\mathrm{M}_\odot$ with LSST 10 year sensitivity. Applying our results to confirmed Milky Way streams, we rank order them by their sensitivity to DM subhalos and identify promising ones for further study.

astro-ph.GA

Listening For New Physics With Quantum Acoustics

We present a novel application of a qubit-coupled phonon detector to search for new physics, e.g., ultralight dark matter (DM) and high-frequency gravitational waves. The detector, motivated by recent advances in quantum acoustics, is composed of superconducting transmon qubits coupled to high-overtone bulk acoustic resonators ($h$BARs) and operates in the GHz - 10 GHz frequency range. New physics can excite $O(10 \, μ\text{eV})$ phonons within the $h$BAR, which are then converted to qubit excitations via a transducer. We detail the design, operation, backgrounds, and expected sensitivity of a prototype detector, as well as a next-generation detector optimized for new physics signals. We find that a future detector can complement current haloscope experiments in the search for both dark photon DM and high-frequency gravitational waves. Lastly we comment on such a detector's ability to operate as a $10 \, μ\text{eV}$ threshold athermal phonon sensor for sub-GeV DM detection.

hep-ph

Low-Energy Radiative Backgrounds in CCD-Based Dark-Matter Detectors

The reach of sub-GeV dark-matter detectors is at present severely affected by low-energy events from various origins. We present the theoretical methods to compute the single- and few-electron events that arise from secondary radiation emitted by high-energy particles passing through detector materials and perform simulations to quantify them at (Skipper) CCD-based experiments, focusing on the SENSEI data collected in the MINOS cavern at Fermilab. The simulations account for the generation of secondaries from Cherenkov and luminescent recombination; photo-absorption, reflection, refraction and thin-film interference in detector materials; roughness of the interfaces and the dynamics of charges and partial charge collection (PCC) in the doped CCD-backside. We consider several systematic uncertainties, notably those stemming from the backside charge-diffusion modeling, which we estimate with a "fiducial'' and an "extreme'' model, with the former model presenting better agreement with PCC data. We find that Cherenkov photons constitute about 40% of the observed single-electron events for both models; radiative recombination rates are negligible for the fiducial model, but can dominate over the Cherenkov rates for the extreme model. We also estimate the fraction of 2-electron events from 1-electron event same-pixel coincidences, finding that the entire 2-electron rate can be explained by coincidences of radiative events and spurious charge. Accounting for backgrounds, we project the sensitivity of future Skipper-CCD-based experiments to different dark-matter models. For light-mediator models with dark-matter masses of 1, 5, and 10 MeV, we find that future experiments with 10-kg-year exposures and successful background mitigation could have a sensitivity that is larger by 9, 3, and 2 orders of magnitude, respectively, when compared to an experiment without background improvements. (abridged)

hep-ph

Anharmonic effects in nuclear recoils from sub-GeV dark matter

Direct detection experiments are looking for nuclear recoils from scattering of sub-GeV dark matter (DM) in crystals, and have thresholds as low as ~ 10 eV or DM masses of ~ 100 MeV. Future experiments are aiming for even lower thresholds. At such low energies, the free nuclear recoil prescription breaks down, and the relevant final states are phonons in the crystal. Scattering rates into single as well as multiple phonons have already been computed for a harmonic crystal. However, crystals typically exhibit some anharmonicity, which can significantly impact scattering rates in certain kinematic regimes. In this work, we estimate the impact of anharmonic effects on scattering rates for DM in the mass range ~ 1-10 MeV, where the details of multiphonon production are most important. Using a simple model of a nucleus in a bound potential, we find that anharmonicity can modify the scattering rates by up to two orders of magnitude for DM masses of O(MeV). However, such effects are primarily present at high energies where the rates are suppressed, and thus only relevant for very large DM cross sections. We show that anharmonic effects are negligible for masses larger than ~ 10 MeV.

hep-ph

Doped Semiconductor Devices for sub-MeV Dark Matter Detection

Dopant atoms in semiconductors can be ionized with $\sim10$ meV energy depositions, allowing for the design of low-threshold detectors. We propose using doped semiconductor targets to search for sub-MeV dark matter scattering or sub-eV dark matter absorption on electrons. Currently unconstrained cross sections could be tested with a 1 g-day exposure in a doped detector with backgrounds at the level of existing pure semiconductor detectors, but improvements would be needed to probe the freeze-in target. We discuss the corresponding technological requirements and lay out a possible detector design.

hep-ph

The Migdal Effect in Semiconductors for Dark Matter with Masses below $\sim \,$100 MeV

Dark matter scattering off a nucleus has a small probability of inducing an observable ionization through the inelastic excitation of an electron, called the Migdal effect. We use an effective field theory to extend the computation of the Migdal effect in semiconductors to regions of small momentum transfer to the nucleus, where the final state of the nucleus is no longer well described by a plane wave. Our analytical result can be fully quantified by the measurable dynamic structure factor of the semiconductor, which accounts for the vibrational degrees of freedom (phonons) in a crystal. We show that, due to the sum rules obeyed by the structure factor, the inclusive Migdal rate and the shape of the electron recoil spectrum is well captured by approximating the nuclei in the crystal as free ions; however, the exclusive differential rate with respect to energy depositions to the crystal depends on the phonon dynamics encoded in the dynamic structure function of the specific material. Our results now allow the Migdal effect in semiconductors to be evaluated even for the lightest dark matter candidates ($m_χ\gtrsim 1$ MeV) that can kinematically excite electrons.

hep-ph

The Phonon Background from Gamma Rays in Sub-GeV Dark Matter Detectors

High-energy photons with $\mathcal{O}$(MeV) energies from radioactive contaminants can scatter in a solid-state target material and constitute an important low-energy background for sub-GeV dark matter direct-detection searches. This background is most noticeable for energy deposits in the $1 - 100$ meV range due to the partially coherent scattering enhancement in the forward scattering direction. We comprehensively quantify the resulting single- and multi-phonon background in Si, Ge, GaAs, SiC, and Al$_2$O$_3$ target materials, which are representative of target materials of interest in low-mass dark matter searches. We use a realistic representation of the high-energy photon background, and contrast the expected background phonon spectrum with the expected dark matter signal phonon spectrum. An active veto is needed to suppress this background sufficiently in order to allow for the detection of a dark matter signal, even in well-shielded environments. For comparison we also show the expected single- and multi-phonon event rates from coherent neutrino-nucleus scattering due to solar neutrinos, and find that they are sub-dominant to the photon-induced phonon background.

hep-ph

Sources of Low-Energy Events in Low-Threshold Dark Matter and Neutrino Detectors

We discuss several low-energy backgrounds to sub-GeV dark matter searches, which arise from high-energy particles of cosmic or radioactive origin that interact with detector materials. We focus in particular on Cherenkov radiation, transition radiation, and luminescence or phonons from electron-hole pair recombination, and show that these processes are an important source of backgrounds at both current and planned detectors. We perform detailed analyses of these backgrounds at several existing and proposed experiments based on a wide variety of detection strategies and levels of shielding. We find that a large fraction of the observed single-electron events in the SENSEI 2020 run originate from Cherenkov photons generated by high-energy events in the Skipper Charge Coupled Device, and from recombination photons generated in a phosphorus-doped layer of the same instrument. In a SuperCDMS HVeV 2020 run, Cherenkov photons produced in printed-circuit-boards located near the sensor likely explain the origin of most of the events containing 2 to 6 electrons. At SuperCDMS SNOLAB, radioactive contaminants inside the Cirlex located inside or on the copper side walls of their detectors will produce many Cherenkov photons, which could dominate the low-energy backgrounds. For the EDELWEISS experiment, Cherenkov or luminescence backgrounds are subdominant to their observed event rate, but could still limit the sensitivity of their future searches. We also point out that Cherenkov radiation, transition radiation, and recombination could be a significant source of backgrounds at future experiments aiming to detect dark-matter via scintillation or phonon signals. We also discuss the implications of our results for the development of superconducting qubits and low-threshold searches for coherent neutrino scattering, and comment on design strategies that can be implemented to mitigate these backgrounds.

hep-ph

Exploring New Physics with O(keV) Electron Recoils in Direct Detection Experiments

Motivated by the recent XENON1T results, we explore various new physics models that can be discovered through searches for electron recoils in O(keV)-threshold direct-detection experiments. First, we consider the absorption of light bosons, either as dark matter relics or being produced directly in the Sun. In the latter case, we find that keV mass bosons produced in the Sun provide an adequate fit to the data but are excluded by stellar cooling constraints. We address this tension by introducing a novel Chameleon-like axion model, which can explain the excess while evading the stellar bounds. We find that absorption of bosonic dark matter provides a viable explanation for the excess only if the dark matter is a dark photon or an axion. In the latter case, photophobic axion couplings are necessary to avoid X-ray constraints. Second, we analyze models of dark matter-electron scattering to determine which models might explain the excess. Standard scattering of dark matter with electrons is generically in conflict with data from lower-threshold experiments. Momentum-dependent interactions with a heavy mediator can fit the data with dark matter mass heavier than a GeV but are generically in tension with collider constraints. Next, we consider dark matter consisting of two (or more) states that have a small mass splitting. The exothermic (down)scattering of the heavier state to the lighter state can fit the data for keV mass splittings. Finally, we consider a subcomponent of dark matter that is accelerated by scattering off cosmic rays, finding that dark matter interacting though an O(100 keV)-mass mediator can fit the data. The cross sections required in this scenario are, however, typically challenged by complementary probes of the light mediator. Throughout our study, we implement an unbinned Monte Carlo analysis and use an improved energy reconstruction of the XENON1T events.

hep-ph

On the relation between Migdal effect and dark matter-electron scattering in isolated atoms and semiconductors

A key strategy for the direct detection of sub-GeV dark matter is to search for small ionization signals. These can arise from dark matter-electron scattering or when the dark matter-nucleus scattering process is accompanied by a "Migdal" electron. We show that the theoretical descriptions of both processes are closely related, which allows for a principal mapping between dark matter-electron and dark matter-nucleus scattering rates once the dark matter interactions with matter are specified. We explore this parametric relationship for noble-liquid targets and, for the first time, provide an estimate of the "Migdal" ionization rate in semiconductors that is based on evaluating a crystal form factor that accounts for the semiconductor band structure. We also present new dark-matter-nucleus scattering limits down to dark matter masses of 500 keV using published data from XENON10, XENON100, and a SENSEI prototype Skipper-CCD. For a dark photon mediator, the dark matter-electron scattering rates dominate over the Migdal rates for dark matter masses below 100 MeV. We also provide projections for proposed experiments with xenon and silicon targets.

hep-ph

Direct Detection of Strongly Interacting Sub-GeV Dark Matter via Electron Recoils

We consider direct-detection searches for sub-GeV dark matter via electron scatterings in the presence of large interactions between dark and ordinary matter. Scatterings both on electrons and nuclei in the Earth's crust, atmosphere, and shielding material attenuate the expected local dark matter flux at a terrestrial detector, so that such experiments lose sensitivity to dark matter above some critical cross section. We study various models, including dark matter interacting with a heavy and ultralight dark photon, through an electric dipole moment, and exclusively with electrons. For a dark-photon mediator and an electric dipole interaction, the dark matter-electron scattering cross-section is directly linked to the dark matter-nucleus cross section, and nuclear interactions typically dominate the attenuation process. We determine the exclusion bands for the different dark-matter models from several experiments - SENSEI, CDMS-HVeV, XENON10, XENON100, and DarkSide-50 - using a combination of Monte Carlo simulations and analytic estimates. We also derive projected sensitivities for a detector located at different depths and for a range of exposures, and calculate the projected sensitivity for SENSEI at SNOLAB and DAMIC-M at Modane. Finally, we discuss the reach to high cross sections and the modulation signature of a small balloon- and satellite-borne detector sensitive to electron recoils, such as a Skipper-CCD. Such a detector could potentially probe unconstrained parameter space at high cross sections for a sub-dominant component of dark matter interacting with a massive, but ultralight, dark photon.

hep-ph

Solar Neutrinos as a Signal and Background in Direct-Detection Experiments Searching for Sub-GeV Dark Matter With Electron Recoils

Direct-detection experiments sensitive to low-energy electron recoils from sub-GeV dark matter (DM) interactions will also be sensitive to solar neutrinos via coherent neutrino-nucleus scattering (CNS), since the recoiling nucleus can produce a small ionization signal. Solar neutrinos constitute both an interesting signal in their own right and a potential background to a DM search that cannot be controlled or reduced by improved shielding, material purification and handling, or improved detector design. We explore these two possibilities in detail for semiconductor (Si and Ge) and Xe targets, considering several possibilities for the unmeasured ionization efficiency at low energies. For DM-electron-scattering searches, neutrinos start being an important background for exposures larger than ~1-10 kg-years in Si and Ge, and for exposures larger than ~0.1-1 kg-year in Xe. For the absorption of bosonic DM (dark photons and axion-like particles) by electrons, neutrinos are most relevant for masses below ~1 keV and again slightly more important in Xe. Treating the neutrinos as a signal, we find that the CNS of B-8 neutrinos can be observed with ~2 sigma significance with exposures of ~2, 7, and 20 kg-years in Xe, Ge, and Si, respectively, assuming there are no other backgrounds. We give an example for how this would constrain non-standard neutrino interactions. Neutrino components at lower energy can only be detected if the ionization efficiency is sufficiently large. In this case, observing pep neutrinos via CNS requires exposures ~10-100 kg-years in Si or Ge (~1000 kg-years in Xe), and observing CNO neutrinos would require an order of magnitude more exposure. Only Si could potentially detect Be-7 neutrinos. These measurements would allow for a direct measurement of the electron-neutrino survival probability over a wide energy range.

hep-ph