Nils Huntemann

Publications and source records attributed to Nils Huntemann.

At least 19 recordsLinked to original sources

Interspecies clock comparison below $5 \times 10^{-18}$ uncertainty with a transportable clock

We report a measurement of the optical frequency ratio between the $^2\mathrm{S}_{1/2}(F=0)$--${^2\mathrm{F}_{7/2}(F=3)}$ electric-octupole (E3) transition of $^{171}$Yb$^{+}$ and the $^1\mathrm{S}_0$--${^3\mathrm{P}_0}$ transition of $^{87}$Sr, $\nu_{\mathrm{Yb}^{+}}/\nu_\mathrm{Sr} = 1.495\,991\,618\,544\,900\,588\,1(65)$. Reaching a fractional uncertainty of $4.3 \times 10^{-18}$, this result improves upon the previous best by more than a factor of three and is among the few that meet the requirements for interspecies clock comparisons specified by the roadmap towards the redefinition of the SI second. The comparison is between a transportable optical lattice clock and a stationary single-ion clock. It spans a period of nearly two years, during which the transportable clock was intermittently operated off-campus. The ratio was reproducibly measured during four separate campaigns, which are consistent within their statistical uncertainties. The results demonstrate reproducible $10^{-18}$ level operation of the transportable clock and thus validate its application for chronometric geodesy and as a transfer standard for inter-institute clock comparisons, e.g., in the absence of optical fiber links.

physics.atom-ph

International Optical Clock Comparison Using the European Optical Fiber Network

Optical clocks have achieved remarkable estimated fractional frequency uncertainties reaching the $10^{-18}$ level and below, enabling applications in fundamental physics, general relativity, and geodesy. However, the challenge of verifying the international consistency of optical clocks remains critical as efforts intensify toward redefining the SI second based on an optical transition or transitions. We report on a two-month international clock comparison campaign involving seven optical clocks in four national metrology institutes (INRIM, LNE-OP, NPL, and PTB) connected via the optical fiber network established in Europe. The campaign resulted in optical frequency ratios with uncertainties ranging from $7.7\times10^{-18}$ to $6.1\times10^{-17}$. Among the results, the $^{171}$Yb$^+$(E3) clocks at NPL and PTB demonstrated agreement within an uncertainty of $7.7\times10^{-18}$, marking the first international verification of two independently developed optical clocks below one part in $10^{17}$. The operation of the $^{199}$Hg clock at LNE-OP (formerly LNE-SYRTE) resulted in frequency ratios with improved uncertainties with $^{171}$Yb$^+$(E3), $^{171}$Yb, and $^{87}$Sr optical clocks. These results provide input for the redefinition of the second and underscore how fiber-linked clock networks can advance metrology and scientific applications.

physics.atom-ph

A multi-ion optical clock with $\mathbf{5 \times 10^{-19}}$ uncertainty

Today's most accurate clocks are based on laser spectroscopy of electronic transitions in single trapped ions and feature fractional frequency uncertainties below $1\times10^{-18}$. Scaling these systems to multiple, simultaneously interrogated ions reduces measurement times, driving recent advances in multi-ion clocks. However, maintaining state-of-the-art systematic uncertainties while increasing the number of ions remains a central challenge. Here, we report on a multi-ion optical atomic clock with a fractional frequency uncertainty of $5.3\times10^{-19}$ and up to 10 \Sr ions. Ion-resolved state detection enables minimization of position-dependent shifts, with residual effects suppressed below the $10^{-20}$-level. Clock operation with eight to ten ions reduces the measurement time by a factor of 4.8 compared to single-ion operation. A comparison with an established \Yb single-ion clock yields an unperturbed frequency ratio of $0.6926711632159660405(20)$, with a statistical uncertainty of $0.9\times10^{-18}$ and a combined uncertainty of $2.9\times 10^{-18}$. These results demonstrate robust multi-ion clock operation with reduced averaging time and state-of-the-art accuracy.

physics.atom-ph

Oscillating nuclear charge radii as sensors for ultralight dark matter

We show that coupling of ultralight dark matter (UDM) to quarks and gluons would lead to an oscillation of the nuclear charge radius for both the quantum chromodynamics (QCD) axion and scalar dark matter. Consequently, the resulting oscillation of electronic energy levels could be resolved with optical atomic clocks, and their comparisons can be used to investigate UDM-nuclear couplings, which were previously only accessible with other platforms. We demonstrate this idea using the ${}^2S_{1/2} (F=0)\leftrightarrow {}^2F_{7/2} (F=3)$ electric octupole and ${}^2S_{1/2} (F=0)\leftrightarrow \,{}^2D_{3/2} (F=2)$ electric quadrupole transitions in ${}^{171}Yb^+$. Based on the derived sensitivity coefficients for these two transitions and a long-term comparison of their frequencies using a single trapped ${}^{171}Yb^+$ ion, we find bounds on the scalar UDM-nuclear couplings and the QCD axion decay constant. These results are at a similar level compared to the tightest spectroscopic limits, and future investigations, also with other optical clocks, promise significant improvements.

hep-ph

The QTF-Backbone: Proposal for a Nationwide Optical Fibre Backbone in Germany for Quantum Technology and Time and Frequency Metrology

The recent breakthroughs in the distribution of quantum information and high-precision time and frequency (T&F) signals over long-haul optical fibre networks have transformative potential for physically secure communications, resilience of timing infrastructure (such as that supporting Global Navigation Satellite Systems (GNSS)) and fundamental physics. To date, these capabilities remain confined to isolated testbeds, with quantum and T&F signals accessible, for example in Germany, to only a few institutions. In this white paper we propose the QTF Backbone: a dedicated national fibre-optic infrastructure in Germany for the networked distribution of Quantum and T&F signals using dark fibres and specialised hardware. The QTF Backbone is planned as a four-phase deployment over ten years to ensure scalable, sustainable access for research institutions and industry. The concept builds on successful demonstrations of time and frequency distribution at high Technology Readiness Levels (TRLs) across Europe, including PTB-MPQ links in Germany, REFIMEVE in France, and the Italian LIFT network. The QTF Backbone will enable transformative Research and Development (R&D), support a nationwide QTF ecosystem, and ensure the transition from innovation to deployment. As a national and European hub, it will position Germany and Europe at the forefront of quantum networking, as well as T&F transfer.

physics.ins-det

Coordinated international comparisons between optical clocks connected via fiber and satellite links

Optical clocks provide ultra-precise frequency references that are vital for international metrology as well as for tests of fundamental physics. To investigate the level of agreement between different clocks, we simultaneously measured the frequency ratios between ten optical clocks in six different countries, using fiber and satellite links. This is the largest coordinated comparison to date, from which we present a subset of 38 optical frequency ratios and an evaluation of the correlations between them. Four ratios were measured directly for the first time, while others had significantly lower uncertainties than previously achieved, supporting the advance towards a redefinition of the second and the use of optical standards for international time scales.

physics.atom-ph

Scalable chip-based 3D ion traps

Ion traps are used for a wide range of applications from metrology to quantum simulations and quantum information processing. Microfabricated chip-based 3D ion traps are scalable to store many ions for the realization of a large number of qubits, provide deep trapping potentials compared to surface traps, and very good shielding from external electric fields. In this work, we give an overview of our recent developments on chip-based 3D ion traps. Different types of chip materials, the integration of electronic filter components on-chip and compact electrical connections in vacuum are discussed. Further, based on finite element method (FEM) simulations, we discuss how integrating micro-optics in 3D ion traps is possible without disturbing the trapped ions.

quant-ph

Excited-state magnetic properties of carbon-like $\text{Ca}^{14+}$

We measured the $g$-factor of the excited state $^3\text{P}_1$ in $\text{Ca}^{14+}$ ion to be $g = 1.499032(6)$ with a relative uncertainty of $4\times10^{-6}$. The magnetic field magnitude is derived from the Zeeman splitting of a $\text{Be}^+$ ion, co-trapped in the same linear Paul trap as the highly charged $\text{Ca}^{14+}$ ion. Furthermore, we experimentally determined the second-order Zeeman coefficient $C_2$ of the $^3\text{P}_0$ - $^3\text{P}_1$ clock transition. For the $m_J=0\rightarrow m_{J'}=0$ transition, we obtain $C_2 = 0.39\pm0.04\text{HzmT}^{-2}$, which is to our knowledge the smallest reported for any atomic transition to date. This confirms the predicted low sensitivity of highly charged ions to higher-order Zeeman effects, making them ideal candidates for high-precision optical clocks. Comparison of the experimental results with our state-of-the art electronic structure calculations shows good agreement, and demonstrates the significance of the frequency-dependent Breit contribution, negative energy states and QED effects on magnetic moments.

physics.atom-ph

Probing new bosons and nuclear structure with ytterbium isotope shifts

In this Letter, we present mass-ratio measurements on highly charged Yb$^{42+}$ ions with a precision of $4\times 10^{-12}$ and isotope-shift measurements on Yb$^{+}$ on the $^{2}$S$_{1/2}$ $\to$ $^{2}$D$_{5/2}$ and $^{2}$S$_{1/2}$ $\to$ $^{2}$F$_{7/2}$ transitions with a precision of $4\times 10^{-9}$ for the isotopes $^{168,170,172,174,176}$Yb. We present a new method that allows us to extract higher-order changes in the nuclear charge distribution along the Yb isotope chain, benchmarking ab-initio nuclear structure calculations. Additionally, we perform a King plot analysis to set bounds on a fifth force in the keV$/c^2$ to MeV$/c^2$ range coupling to electrons and neutrons.

physics.atom-ph

Ultralight Dark Matter Search with Space-Time Separated Atomic Clocks and Cavities

We devise and demonstrate a method to search for non-gravitational couplings of ultralight dark matter to standard model particles using space-time separated atomic clocks and cavity-stabilized lasers. By making use of space-time separated sensors, which probe different values of an oscillating dark matter field, we can search for couplings that cancel in typical local experiments. This provides sensitivity to both the temporal and spatial fluctuations of the field. We demonstrate this method using existing data from a frequency comparison of lasers stabilized to two optical cavities connected via a 2220 km fiber link [Schioppo et al., Nat. Commun. 13, 212 (2022)], and from the atomic clocks on board the Global Position System satellites. Our analysis results in constraints on the coupling of scalar dark matter to electrons, d_me, for masses between 1e-19 eV/c^2 and 2e-15 eV/c^2. These are the first constraints on d_me alone in this mass range.

hep-ph

An Optical Atomic Clock Based on a Highly Charged Ion

Optical atomic clocks are the most accurate measurement devices ever constructed and have found many applications in fundamental science and technology. The use of highly charged ions (HCI) as a new class of references for highest accuracy clocks and precision tests of fundamental physics has long been motivated by their extreme atomic properties and reduced sensitivity to perturbations from external electric and magnetic fields compared to singly charged ions or neutral atoms. Here we present the first realisation of this new class of clocks, based on an optical magnetic-dipole transition in Ar$^{13+}$. Its comprehensively evaluated systematic frequency uncertainty of $2.2\times10^{-17}$ is comparable to that of many optical clocks in operation. From clock comparisons we improve by eight and nine orders of magnitude upon the uncertainties for the absolute transition frequency and isotope shift ($^{40}$Ar vs. $^{36}$Ar), respectively. These measurements allow us to probe the largely unexplored quantum electrodynamic nuclear recoil, presented as part of improved calculations of the isotope shift which reduce the uncertainty of previous theory by a factor of three. This work establishes forbidden optical transitions in HCI as references for cutting-edge optical clocks and future high-sensitivity searches for physics beyond the standard model.

physics.atom-ph

Optical frequency ratio of a ${}^{171}\mathrm{Yb}^+$ single-ion clock and a ${}^{87}\mathrm{Sr}$ lattice clock

We report direct measurements of the frequency ratio of the 642 THz ${}^2S_{1/2} (F=0)$--${}^2F_{7/2} (F=3)$ electric octupole transition in ${}^{171}\mathrm{Yb}^+$ and the 429 THz ${}^1S_0$--${}^3P_0$ transition in ${}^{87}\mathrm{Sr}$. A series of 107 measurements has been performed at the Physikalisch-Technische Bundesanstalt between December 2012 and October 2019. Long-term variations of the ratio are larger than expected from the individual measurement uncertainties of few $10^{-17}$. The cause of these variations remains unknown. Even taking these into account, we find a fractional uncertainty of the frequency ratio of $2.5 \times 10^{-17}$, which improves upon previous knowledge by one order of magnitude. The average frequency ratio is $ν_{\mathrm{Yb}^+} / ν_{\mathrm{Sr}} = 1.495\,991\,618\,544\,900\,537(38)$. This represents one of the most accurate measurements between two different atomic species to date.

physics.atom-ph

Coherent excitation of the highly forbidden electric octupole transition in ${}^{172}$Yb$^+$

We report on the first coherent excitation of the highly forbidden $^2S_{1/2}\rightarrow{}^2F_{7/2}$ electric octupole (E3) transition in a single trapped ${}^{172}$Yb$^+$ ion, an isotope without nuclear spin. Using the transition in ${}^{171}$Yb$^+$ as a reference, we determine the transition frequency to be $642\,116\,784\,950\,887.6(2.4)\,$Hz. We map out the magnetic field environment using the forbidden $^2S_{1/2} \rightarrow{}^2D_{5/2}$ electric quadrupole (E2) transition and determine its frequency to be $729\,476\,867\,027\,206.8(4.4)\,$Hz. Our results are a factor of $1\times10^5$ ($3\times10^{5}$) more accurate for the E2 (E3) transition compared to previous measurements. The results open up the way to search for new physics via precise isotope shift measurements and improved tests of local Lorentz invariance using the metastable $^2F_{7/2}$ state of Yb$^+$.

physics.atom-ph

Guidelines for developing optical clocks with $10^{-18}$ fractional frequency uncertainty

There has been tremendous progress in the performance of optical frequency standards since the first proposals to carry out precision spectroscopy on trapped, single ions in the 1970s. The estimated fractional frequency uncertainty of today's leading optical standards is currently in the $10^{-18}$ range, approximately two orders of magnitude better than that of the best caesium primary frequency standards. This exceptional accuracy and stability is resulting in a growing number of research groups developing optical clocks. While good review papers covering the topic already exist, more practical guidelines are needed as a complement. The purpose of this document is therefore to provide technical guidance for researchers starting in the field of optical clocks. The target audience includes national metrology institutes (NMIs) wanting to set up optical clocks (or subsystems thereof) and PhD students and postdocs entering the field. Another potential audience is academic groups with experience in atomic physics and atom or ion trapping, but with less experience of time and frequency metrology and optical clock requirements. These guidelines have arisen from the scope of the EMPIR project "Optical clocks with $1 \times 10^{-18}$ uncertainty" (OC18). Therefore, the examples are from European laboratories even though similar work is carried out all over the world. The goal of OC18 was to push the development of optical clocks by improving each of the necessary subsystems: ultrastable lasers, neutral-atom and single-ion traps, and interrogation techniques. This document shares the knowledge acquired by the OC18 project consortium and gives practical guidance on each of these aspects.

physics.atom-ph

Optical clock comparison test of Lorentz symmetry

Questioning the presumably most basic assumptions about the structure of space and time has revolutionized our understanding of Nature. State-of-the-art atomic clocks make it possible to precisely test fundamental symmetry properties of spacetime, and search for physics beyond the standard model at low energy scales of just a few electron volts. Here, we experimentally demonstrate for the first time agreement of two single-ion clocks at the $10^{-18}$ level and directly confirm the validity of their uncertainty budgets over a half-year long comparison period. The two clock ions are confined in separate ion traps with quantization axes aligned along nonparallel directions. Hypothetical Lorentz symmetry violations would lead to sidereal modulations of the frequency offset. From the absence of such modulations at the $10^{-19}$ level we deduce stringent limits on Lorentz symmetry violation parameters for electrons in the range of $10^{-21}$, improving previous limits by two orders of magnitude.

physics.atom-ph

Auto-Balanced Ramsey Spectroscopy

We devise a perturbation-immune version of Ramsey's method of separated oscillatory fields. Spectroscopy of an atomic clock transition without compromising the clock's accuracy is accomplished by actively balancing the spectroscopic responses from phase-congruent Ramsey probe cycles of unequal durations. Our simple and universal approach eliminates a wide variety of interrogation-induced line shifts often encountered in high precision spectroscopy, among them, in particular, light shifts, phase chirps, and transient Zeeman shifts. We experimentally demonstrate auto-balanced Ramsey spectroscopy on the light shift prone $^{171}$Yb$^{+}$ electric octupole optical clock transition and show that interrogation defects are not turned into clock errors. This opens up frequency accuracy perspectives below the $10^{-18}$ level for the Yb$^{+}$ system and for other types of optical clocks.

physics.atom-ph

Analysis of thermal radiation in ion traps for optical frequency standards

In many of the high-precision optical frequency standards with trapped atoms or ions that are under development to date, the AC Stark shift induced by thermal radiation leads to a major contribution to the systematic uncertainty. We present an analysis of the inhomogeneous thermal environment experienced by ions in various types of ion traps. Finite element models which allow the determination of the temperature of the trap structure and the temperature of the radiation were developed for 5 ion trap designs, including operational traps at PTB and NPL and further optimized designs. Models were refined based on comparison with infrared camera measurement until an agreement of better than 10% of the measured temperature rise at critical test points was reached. The effective temperature rises of the radiation seen by the ion range from 0.8 K to 2.1 K at standard working conditions. The corresponding fractional frequency shift uncertainties resulting from the uncertainty in temperature are in the 10-18 range for optical clocks based on the Sr+ and Yb+ E2 transitions, and even lower for Yb+ E3, In+ and Al+. Issues critical for heating of the trap structure and its predictability were identified and design recommendations developed.

physics.atom-ph

A strontium lattice clock with $3 \times 10^{-17}$ inaccuracy and its frequency

We have measured the absolute frequency of the optical lattice clock based on $^{87}$Sr at PTB with an uncertainty of $3.9\times 10^{-16}$ using two caesium fountain clocks. This is close to the accuracy of today's best realizations of the SI second. The absolute frequency of the 5s$^2$ $^1$S$_0$-5s5p $^3$P$_0$ transition in $^{87}$Sr is 429,228,004,229,873.13(17) Hz. Our result is in excellent agreement with recent measurements performed in different laboratories worldwide. We improved the total systematic uncertainty of our Sr frequency standard by a factor of five and reach $3\times 10^{-17}$, opening new prospects for frequency ratio measurements between optical clocks for fundamental research, geodesy, or optical clock evaluation.

physics.atom-ph