arXiv · 2009.05470
Optical frequency ratio of a ${}^{171}\mathrm{Yb}^+$ single-ion clock and a ${}^{87}\mathrm{Sr}$ lattice clock
Abstract
We report direct measurements of the frequency ratio of the 642 THz ${}^2S_{1/2} (F=0)$--${}^2F_{7/2} (F=3)$ electric octupole transition in ${}^{171}\mathrm{Yb}^+$ and the 429 THz ${}^1S_0$--${}^3P_0$ transition in ${}^{87}\mathrm{Sr}$. A series of 107 measurements has been performed at the Physikalisch-Technische Bundesanstalt between December 2012 and October 2019. Long-term variations of the ratio are larger than expected from the individual measurement uncertainties of few $10^{-17}$. The cause of these variations remains unknown. Even taking these into account, we find a fractional uncertainty of the frequency ratio of $2.5 \times 10^{-17}$, which improves upon previous knowledge by one order of magnitude. The average frequency ratio is $\nu_{\mathrm{Yb}^+} / \nu_{\mathrm{Sr}} = 1.495\,991\,618\,544\,900\,537(38)$. This represents one of the most accurate measurements between two different atomic species to date.
Explore related subjects
Keep this discovery
Sören Dörscher, Nils Huntemann, Roman Schwarz, Richard Lange, Erik Benkler, Burghard Lipphardt, Uwe Sterr, Ekkehard Peik, Christian Lisdat. 2020-09-11. Optical frequency ratio of a ${}^{171}\mathrm{Yb}^+$ single-ion clock and a ${}^{87}\mathrm{Sr}$ lattice clock. https://doi.org/10.1088/1681-7575/abc86f
Cite the original work for its findings. Save a collection to share your selection of sources.