Searcharxiv⌕ Search

arXiv subjects

Noah Kurinsky

Publications and source records attributed to Noah Kurinsky.

35 records · Page 2Linked to original sources

Snowmass2021 Cosmic Frontier White Paper: Calibrations and backgrounds for dark matter direct detection

Future dark matter direct detection experiments will reach unprecedented levels of sensitivity. Achieving this sensitivity will require more precise models of signal and background rates in future detectors. Improving the precision of signal and background modeling goes hand-in-hand with novel calibration techniques that can probe rare processes and lower threshold detector response. The goal of this white paper is to outline community needs to meet the background and calibration requirements of next-generation dark matter direct detection experiments.

hep-ex↗

Broadband solenoidal haloscope for terahertz axion detection

We introduce the Broadband Reflector Experiment for Axion Detection (BREAD) conceptual design and science program. This haloscope plans to search for bosonic dark matter across the [10$^{-3}$, 1] eV ([0.24, 240] THz) mass range. BREAD proposes a cylindrical metal barrel to convert dark matter into photons, which a novel parabolic reflector design focuses onto a photosensor. This unique geometry enables enclosure in standard cryostats and high-field solenoids, overcoming limitations of current dish antennas. A pilot 0.7 m$^{2}$ barrel experiment planned at Fermilab is projected to surpass existing dark photon coupling constraints by over a decade with one-day runtime. Axion sensitivity requires $<10^{-20}$ W/$\sqrt{\textrm{Hz}}$ sensor noise equivalent power with a 10 T solenoid and 10 m$^{2}$ barrel. We project BREAD sensitivity for various sensor technologies and discuss future prospects.

physics.ins-det↗

Directional Detection of Light Dark Matter in Superconductors

Superconducting detectors have been proposed as outstanding targets for the direct detection of light dark matter scattering at masses as low as a keV. We study the prospects for directional detection of dark matter in isotropic superconducting targets from the angular distribution of excitations produced in the material. We find that dark matter scattering produces initial excitations with an anisotropic distribution, and further show that this directional information can be preserved as the initial excitations relax. Our results demonstrate that directional detection is possible for a wide range of dark matter masses, and pave the way for light dark matter discovery with bulk superconducting targets.

hep-ph↗

Design and performance of a multi-terahertz Fourier transform spectrometer for axion dark matter experiments

Dedicated spectrometers for terahertz radiation with [0.3, 30] THz frequencies using traditional optomechanical interferometry are substantially less common than their infrared and microwave counterparts. This paper presents the design and initial performance measurements of a tabletop Fourier transform spectrometer (FTS) for multi-terahertz radiation using infrared optics in a Michelson arrangement. This is coupled to a broadband pyroelectric photodetector designed for [0.1, 30] THz frequencies. We measure spectra of narrowband and broadband input radiation to characterize the performance of this instrument above 10 THz, where signal-to-noise is high. This paves the groundwork for planned upgrades to extend below 10 THz. We also briefly discuss potential astroparticle physics applications of such FTS instruments to broadband axion dark matter searches, whose signature comprises low-rate monochromatic photons with unknown frequency.

physics.ins-det↗

Characterization of Skipper CCDs for Cosmological Applications

We characterize the response of a novel 250 $μ$m thick, fully-depleted Skipper Charged-Coupled Device (CCD) to visible/near-infrared light with a focus on potential applications for astronomical observations. We achieve stable, single-electron resolution with readout noise $σ\sim 0.18$ e$^{-}$ rms/pix from 400 non-destructive measurements of the charge in each pixel. We verify that the gain derived from photon transfer curve measurements agrees with the gain calculated from the quantized charge of individual electrons to within < 1%. We also perform relative quantum efficiency measurements and demonstrate high relative quantum efficiency at optical/near-infrared wavelengths, as is expected for a thick, fully depleted detector. Finally, we demonstrate the ability to perform multiple non-destructive measurements and achieve sub-electron readout noise over configurable subregions of the detector. This work is the first step toward demonstrating the utility of Skipper CCDs for future astronomical and cosmological applications.

astro-ph.IM↗

SiC Detectors for Sub-GeV Dark Matter

We propose the use of silicon carbide (SiC) for direct detection of sub-GeV dark matter. SiC has properties similar to both silicon and diamond, but has two key advantages: (i) it is a polar semiconductor which allows sensitivity to a broader range of dark matter candidates; and (ii) it exists in many stable polymorphs with varying physical properties, and hence has tunable sensitivity to various dark matter models. We show that SiC is an excellent target to search for electron, nuclear and phonon excitations from scattering of dark matter down to 10 keV in mass, as well as for absorption processes of dark matter down to 10 meV in mass. Combined with its widespread use as an alternative to silicon in other detector technologies and its availability compared to diamond, our results demonstrate that SiC holds much promise as a novel dark matter detector.

hep-ph↗

Ionization Yield in Silicon for eV-Scale Electron-Recoil Processes

The development of single charge resolving, macroscopic silicon detectors has opened a window into rare processes at the O(eV) scale. In order to reconstruct the energy of a given event, or model the charge signal obtained for a given amount of energy absorbed by the electrons in a detector, an accurate charge yield model is needed. In this paper we review existing measurements of charge yield in Silicon, focusing in particular on the region below 1 keV. We highlight a calibration gap between 12-50 eV (referred to as the "UV-gap") and employ a phenomenological model of impact ionization to explore the likely charge yield in this energy regime. Finally, we explore the impact of variations in this model on a test case, that of dark matter scattering off electrons, to illustrate the scientific impact of uncertainties in charge yield.

astro-ph.IM↗

A Dark Matter Interpretation of Excesses in Multiple Direct Detection Experiments

We present a novel unifying interpretation of excess event rates observed in several dark matter direct-detection experiments that utilize single-electron threshold semiconductor detectors. Despite their different locations, exposures, readout techniques, detector composition, and operating depths, these experiments all observe statistically significant excess event rates of $\sim$ 10 Hz/kg. However, none of these persistent excesses has yet been reported as a dark matter signal because individually, each can be attributed to different well-motivated but unmodeled backgrounds, and taken together, they cannot be explained by dark matter particles scattering elastically off detector nuclei or electrons. We show that these results can be reconciled if the semiconductor detectors are seeing a collective inelastic process, consistent with exciting a plasmon. We further show that plasmon excitation could arise in two compelling dark matter scenarios, both of which can explain rates of existing signal excesses in germanium and, at least at the order of magnitude level, across several single-electron threshold detectors. At least one of these scenarios also yields the correct relic density from thermal freeze-out. Both dark matter scenarios motivate a radical rethinking of the standard interpretations of dark matter-electron scattering from recent experiments.

hep-ph↗

Reply to Robinson and Michaud, arXiv:2002.08893

We respond to Robinson and Michaud's (RM) comment (arXiv:2002.08893) on our recent preprint arXiv:2002.06937, in which we discuss recent excesses in low-threshold dark matter searches, and offer a potential unifying dark matter interpretation. We thank RM for their feedback, which highlights the critical need for future measurements to directly calibrate plasmon charge yields for low $\sim$ 10 eV energy depositions. RM objected to our assertion that plasmons generated at energy scales below 100~eV may have a large branching fraction into phonons. As we argue below, the points raised by RM do not invalidate our primary conclusions, as they pertain to a much different energy scale than we discuss in our paper.

hep-ph↗

Single Electron-Hole Pair Sensitive Silicon Detector with Surface Event Rejection

We demonstrate single electron-hole pair resolution in a single-sided, contact-free 1 cm$^2$ by 1 mm thick Si crystal operated at 48 mK, with a baseline energy resolution of 3 eV. This crystal can be operated at voltages in excess of $\pm50$ V, resulting in a measured charge resolution of 0.06 electron-hole pairs. The high aluminum coverage ($\sim$70%) of this device allows for the discrimination of surface events and separation of events occurring near the center of the detector from those near the edge. We use this discrimination ability to show that non-quantized dark events seen in previous detectors of a similar design are likely dominated by charge leakage along the side wall of the device.

physics.ins-det↗

Energy Loss Due to Defect Formation from $^{206}$Pb Recoils in SuperCDMS Germanium Detectors

The Super Cryogenic Dark Matter Search experiment (SuperCDMS) at the Soudan Underground Laboratory studied energy loss associated with Frenkel defect formation in germanium crystals at mK temperatures using in situ $^{210}$Pb sources. We examine the spectrum of $^{206}$Pb nuclear recoils near its expected 103 keV endpoint energy and determine an energy loss of $\left(6.08\pm0.18\right)$ %, which we attribute to defect formation. From this result and using TRIM simulations, we extract the first experimentally determined average displacement threshold energy of $\left(19.7^{+0.6}_{-0.5}\right)$ eV for germanium. This has implications for the analysis thresholds of future germanium-based dark matter searches.

physics.ins-det↗

Diamond Detectors for Direct Detection of Sub-GeV Dark Matter

We propose to use high-purity lab-grown diamond for the detection of sub-GeV dark matter. Diamond targets can be sensitive to both nuclear and electron recoils from dark matter scattering in the MeV and above mass range, as well as to absorption processes of dark matter with masses between sub-eV to 10's of eV. Compared to other proposed semiconducting targets such as germanium and silicon, diamond detectors can probe lower dark matter masses via nuclear recoils due to the lightness of the carbon nucleus. The expected reach for electron recoils is comparable to that of germanium and silicon, with the advantage that dark counts are expected to be under better control. Via absorption processes, unconstrained QCD axion parameter space can be successfully probed in diamond for masses of order 10 eV, further demonstrating the power of our approach.

hep-ex↗

Exploring the evolution of star formation and dwarf galaxy properties with JWST/MIRI serendipitous spectroscopic surveys

The James Webb Space Telescope's Medium Resolution Spectrometer (MRS), will offer nearly 2 orders of magnitude improvement in sensitivity and >3X improvement in spectral resolution over our previous space-based mid-IR spectrometer, the Spitzer IRS. In this paper, we make predictions for spectroscopic pointed observations and serendipitous detections with the MRS. Specifically, pointed observations of Herschel sources require only a few minutes on source integration for detections of several star-forming and active galactic nucleus lines, out to z$=$3 and beyond. But the same data will also include tens of serendipitous 0$\lesssim$z$\lesssim$4 galaxies per field with infrared luminosities ranging $\sim10^6-10^{13}$L$_{\odot}$. In particular, for the first time and for free we will be able to explore the $L_{IR}<10^{9}L_{\odot}$ regime out to $z\sim3$. We estimate that with $\sim$100 such fields, statistics of these detections will be sufficient to constrain the evolution of the low-$L$ end of the infrared luminosity function, and hence the star formation rate function. The above conclusions hold for a wide range in potential low-$L$ end of the IR luminosity function, and accounting for the PAH deficit in low-$L$, low-metallicity galaxies.

astro-ph.GA↗

SuperCDMS SNOLAB Low-Mass Detectors: Ultra-Sensitive Phonon Calorimeters for a Sub-GeV Dark Matter Search

We present the technical design for the SuperCDMS high-voltage, low-mass dark matter detectors, designed to be sensitive to dark matter down to 300 MeV/$c^2$ in mass and resolve individual electron-hole pairs from low-energy scattering events in high-purity Ge and Si crystals. In this paper we discuss some of the studies and technological improvements which have allowed us to design such a sensitive detector, including advances in phonon sensor design and detector simulation. With this design we expect to achieve better than 10 eV (5 eV) phonon energy resolution in our Ge (Si) detectors, and recoil energy resolution below 1eV by exploiting Luke-Neganov phonon generation of charges accelerated in high fields.

physics.ins-det↗

The evolution in the stellar mass of Brightest Cluster Galaxies over the past 10 billion years

Using a sample of 98 galaxy clusters recently imaged in the near infra-red with the ESO NTT, WIYN and WHT telescopes, supplemented with 33 clusters from the ESO archive, we measure how the stellar mass of the most massive galaxies in the universe, namely Brightest Cluster Galaxies (BCG), increases with time. Most of the BCGs in this new sample lie in the redshift range $0.2<z<0.6$, which has been noted in recent works to mark an epoch over which the growth in the stellar mass of BCGs stalls. From this sample of 132 clusters, we create a subsample of 102 systems that includes only those clusters that have estimates of the cluster mass. We combine the BCGs in this subsample with BCGs from the literature, and find that the growth in stellar mass of BCGs from 10 billion years ago to the present epoch is broadly consistent with recent semi-analytic and semi-empirical models. As in other recent studies, tentative evidence indicates that the stellar mass growth rate of BCGs may be slowing in the past 3.5 billion years. Further work in collecting larger samples, and in better comparing observations with theory using mock images is required if a more detailed comparison between the models and the data is to be made.

astro-ph.GA↗

Robust Constraint of Luminosity Function Evolution Through MCMC Sampling

We present a new galaxy survey simulation package, which combines the power of Markov Chain Monte Carlo (MCMC) sampling with a robust and adaptable model of galaxy evolution. The aim of this code is to aid in the characterization and study of new and existing galaxy surveys. In this paper we briefly describe the MCMC implementation and the survey simulation methodology and associated tools. A test case of this full suite was to constrain the evolution of the IR Luminosity Function (LF) based on the HerMES (Herschel SPIRE) survey of the Spitzer First Look Survey field. The initial results are consistent with previous studies, but our more general approach should be of wider benefit to the community.

astro-ph.IM↗

VLA/JVLA Monitoring of Bright Northern Radio Sources

We report multiple epoch VLA/JVLA observations of 89 northern hemisphere sources, most with 37\,GHz flux density > 1 Jy, observed at 4.8, 8.5, 33.5, and 43.3 GHz. The high frequency selection leads to a predominantly flat spectrum sample, with 85% of our sources being in the Planck Early Release Compact Source Catalog (ERCSC). These observations allow us to: 1) validate Planck's 30 and 44 GHz flux density scale, 2) extend the radio SEDs of Planck sources to lower frequencies allowing for the full 5-857GHz regime to be studied, and 3) characterize the variability of these sources. At 30 GHz and 44 GHz, the JVLA and Planck flux densities agree to within 3%. On timescales of less than two months the median variability of our sources is 2%. On timescales of about a year the median variability increases to 14%. Using the WMAP 7-year data, the 30 GHz median variability on a 1-6 years timescale is 16%.

astro-ph.CO↗