Searcharxiv⌕ Search

arXiv subjects

Olivier Limousin

Publications and source records attributed to Olivier Limousin.

At least 19 recordsLinked to original sources

Responses of the X-ray spectrometer/imager STIX onboard Solar Orbiter

Solar flares are explosive events that release X-rays from hot plasma and accelerated electrons. The STIX instrument on the Solar Orbiter provides imaging spectroscopy of solar X-ray emissions from 4 to 150 keV. To interpret the STIX data accurately, understanding the instrument's response is crucial. Given the complexity of interactions of X-rays with the instrument, we developed a detailed Monte Carlo model for STIX based on Geant4. The model accurately depicts the instrument's components, such as grids, detectors, X-ray windows, and collimators, with their responses. We studied various effects, including grid shadowing, fluorescent X-rays emitted by materials in STIX, and grid transmission, to assess their impacts on STIX's scientific goals. Model validation was performed using Crab Nebula observations, a standard calibration source that provides reliable ground truth for X-ray instruments. Our simulations align with the Crab Nebula observations within the uncertainties, thereby validating the accuracy of the Geant4 model and showcasing its potential for interpreting STIX data. With the help of the generated response matrices, which are indispensable for solar spectroscopy, we discuss the applications and limitations of the model for future STIX data analysis.

astro-ph.SR↗

Using the STIX background detector as a proxy for GOES

Context. The Spectrometer/Telescope for Imaging X-Rays (STIX) onboard Solar Orbiter was designed to observe solar flares in the X-ray range of 4-150 keV, providing spectral, temporal and spatial information. Besides 30 imaging detectors, STIX has two additional detectors, the coarse flare locator (CFL) and the background (BKG) detector. Flares observed from Earth are classified using their peak X-ray flux observed by the GOES satellites. Roughly half of all flares observed by STIX are located on the backside of the Sun. These flares lack a GOES-class classification. Aims. In this paper, we describe the calibration of the BKG detector aperture sizes. Using the calibrated measurements of the BKG detector, we explore the relationship between the peak flux for flares jointly observed by STIX and GOES. This allows us to estimate the GOES flare classes of backside flares using STIX measurements. Methods. We looked at the 500 largest flares observed by both STIX and GOES in the time range Feb. 21 to Apr. 23. Aperture size calibration is done by comparing 4-10 keV counts of the BKG detector with the CFL measurements. In a second step, we correlate the calibrated STIX BKG peak flux with the GOES peak flux for individual flares. Results. We calibrated the BKG detector aperture sizes of STIX. Further, we showed that for the larger flares a close power law fit exists between the STIX BKG and GOES peak flux with a Pearson correlation coefficient of 0.97. This correlation provides a GOES proxy with a one sigma uncertainty of 11%. We were able to show that the BKG detector can reliably measure a broad range of GOES flare classes from roughly B5 up to at least X85 (assuming a radial distance of 1AU), making it an interesting detector-concept for future space weather missions. The largest flare observed by STIX to date is an estimated X16.5 $\pm$ 1.8 backside flare on the 20 Mai 2024.

astro-ph.SR↗

The Wide Field Monitor (WFM) of the China-Europe eXTP (enhanced X-ray Timing and Polarimetry) mission

The eXTP mission is a major project of the Chinese Academy of Sciences (CAS), with a large involvement of Europe. Its scientific payload includes four instruments: SFA, PFA, LAD and WFM. They offer an unprecedented simultaneous wide-band Xray timing and polarimetry sensitivity. A large European consortium is contributing to the eXTP study, both for the science and the instrumentation. Europe is expected to provide two of the four instruments: LAD and WFM; the LAD is led by Italy and the WFM by Spain. The WFM for eXTP is based on the design originally proposed for the LOFT ESA M3 mission, that underwent a Phase A feasibility study. It will be a wide field of view X-ray monitor instrument working in the 2-50 keV energy range, achieved with large-area Silicon Drift Detectors (SDDs), similar to the ones used for the LAD but with better spatial resolution. The WFM will consist of 3 pairs of coded mask cameras with a total combined field of view (FoV) of 90x180 degrees at zero response and a source localisation accuracy of ~1 arc min. The main goal of the WFM is to provide triggers for the target of opportunity observations of the SFA, PFA and LAD, in order to perform the core science programme, dedicated to the study of matter under extreme conditions of density, gravity and magnetism. In addition, the unprecedented combination of large field of view and imaging capability, down to 2 keV, of the WFM will allow eXTP to make important discoveries of the variable and transient X-ray sky, and provide X-ray coverage of a broad range of astrophysical objects covered under 'observatory science', such as gamma-ray bursts, fast radio bursts, gravitational wave electromagnetic counterparts. In this paper we provide an overview of the WFM instrument, explaining its design, configuration, and anticipated performance.

astro-ph.IM↗

X-ray spectral performance of the Sony IMX290 CMOS sensor near Fano limit after a per-pixel gain calibration

The advent of back-illuminated complementary metal-oxide-semiconductor (CMOS) sensors and their well-known advantages over charge-coupled devices (CCDs) make them an attractive technology for future X-ray missions. However, numerous challenges remain, including improving their depletion depth and identifying effective methods to calculate per-pixel gain conversion. We have tested a commercial Sony IMX290LLR CMOS sensor under X-ray light using an $^{55}$Fe radioactive source and collected X-ray photons for $\sim$15 consecutive days under stable conditions at regulated temperatures of 21°C and 26°C. At each temperature, the data set contained enough X-ray photons to produce one spectrum per pixel consisting only of single-pixel events. We determined the gain dispersion of its 2.1 million pixels using the peak fitting and the Energy Calibration by Correlation (ECC) methods. We measured a gain dispersion of 0.4\% at both temperatures and demonstrated the advantage of the ECC method in the case of spectra with low statistics. The energy resolution at 5.9 keV after the per-pixel gain correction is improved by $\gtrsim$10 eV for single-pixel and all event spectra, with single-pixel event energy resolution reaching $123.6\pm 0.2$ eV, close to the Fano limit of silicon sensors at room temperature. Finally, our long data acquisition demonstrated the excellent stability of the detector over more than 30 days under a flux of $10^4$ photons per second.

physics.ins-det↗

Energetic particle contamination in STIX during Solar Orbiter's passage through Earth's radiation belts and an interplanetary shock

The Spectrometer/Telescope for Imaging X-rays (STIX) is a hard X-ray imaging spectrometer on board the ESA and NASA heliospheric mission Solar Orbiter. STIX has been operational for three years and has observed X-ray emission from ~35,000 solar flares. Throughout its lifetime, Solar Orbiter has been frequently struck by a high flux of energetic particles usually of flare origin, or from coronal mass ejection shocks. These Solar Energetic Particles (SEPs) are detected on board by the purpose-built energetic particle detector instrument suite. During SEP events, the X-ray signal is also contaminated in STIX. This work investigates the effect of these particles on the STIX instrument for two events. The first event occurred during an interplanetary shock crossing and the second event occurred when Solar Orbiter passed through Earth's radiation belts while performing a gravity assist maneuver. The induced spectra consist of tungsten fluorescence emission lines and secondary Bremsstrahlung emission produced by incident particles interacting with spacecraft components. For these two events, we identify > 100 keV electrons as significant contributors to the contamination via Bremsstrahlung emission and tungsten fluorescence.

astro-ph.SR↗

The TRILL project: increasing the technological readiness of Laue lenses

Hard X-/soft Gamma-ray astronomy (> 100 keV) is a crucial field for the study of important astrophysical phenomena such as the 511 keV positron annihilation line in the Galactic center region and its origin, gamma-ray bursts, soft gamma-ray repeaters, nuclear lines from SN explosions and more. However, several key questions in this field require sensitivity and angular resolution that are hardly achievable with present technology. A new generation of instruments suitable to focus hard X-/soft Gamma-rays is necessary to overcome the technological limitations of current direct-viewing telescopes. One solution is using Laue lenses based on Bragg's diffraction in a transmission configuration. To date, this technology is in an advanced stage of development and further efforts are being made in order to significantly increase its technology readiness level (TRL). To this end, massive production of suitable crystals is required, as well as an improvement of the capability of their alignment. Such a technological improvement could be exploited in stratospheric balloon experiments and, ultimately, in space missions with a telescope of about 20 m focal length, capable of focusing over a broad energy pass-band. We present the latest technological developments of the TRILL (Technological Readiness Increase for Laue Lenses) project, supported by ASI, devoted to the advancement of the technological readiness of Laue lenses. We show the method we developed for preparing suitable bent Germanium and Silicon crystals and the latest advancements in crystals alignment technology.

astro-ph.IM↗

The data center for the Spectrometer and Telescope for Imaging X-rays (STIX) onboard Solar Orbiter

The Spectrometer and Telescope for Imaging X-rays (STIX) on board Solar Orbiter observes solar X-ray emission in the range of 4 – 150 keV and produces spectra and images of solar flares over a wide range of flare magnitudes. During nominal operation, STIX continuously generates data. A constant data flow requires fully automated data-processing pipelines to process and analyze the data, and a data platform to manage, visualize, and distribute the data products to the scientific community. The STIX Data Center has been built to fulfill these needs. In this paper, we outline its main components to help the community better understand the tools and data it provides. The STIX Data Center is operated at the University of Applied Sciences and Arts Northwestern Switzerland (FHNW) and consists of automated processing pipelines and a data platform. The pipelines process STIX telemetry data, perform common analysis tasks, and generate data products at different processing levels. They have been designed to operate fully automatically with minimal human intervention. The data platform provides web-based user interfaces and application programmable interfaces for searching and downloading STIX data products. The STIX Data Center has been operating successfully for more than two years. The platform facilitates instrument operations and provides vital support to STIX data users.

astro-ph.SR↗

STIX X-ray microflare observations during the Solar Orbiter commissioning phase

The Spectrometer/Telescope for Imaging X-rays (STIX) is the HXR instrument onboard Solar Orbiter designed to observe solar flares over a broad range of flare sizes, between 4-150 keV. We report the first STIX observations of microflares recorded during the instrument commissioning phase in order to investigate the STIX performance at its detection limit. This first result paper focuses on the temporal and spectral evolution of STIX microflares occuring in the AR12765 in June 2020, and compares the STIX measurements with GOES/XRS, SDO/AIA, and Hinode/XRT. For the observed microflares of the GOES A and B class, the STIX peak time at lowest energies is located in the impulsive phase of the flares, well before the GOES peak time. Such a behavior can either be explained by the higher sensitivity of STIX to higher temperatures compared to GOES, or due to the existence of a nonthermal component reaching down to low energies. The interpretation is inconclusive due to limited counting statistics for all but the largest flare in our sample. For this largest flare, the low-energy peak time is clearly due to thermal emission, and the nonthermal component seen at higher energies occurs even earlier. This suggests that the classic thermal explanation might also be favored for the majority of the smaller flares. In combination with EUV and SXR observations, STIX corroborates earlier findings that an isothermal assumption is of limited validity. Future diagnostic efforts should focus on multi-wavelength studies to derive differential emission measure distributions over a wide range of temperatures to accurately describe the energetics of solar flares. Commissioning observations confirm that STIX is working as designed. As a rule of thumb, STIX detects flares as small as the GOES A class. For flares above the GOES B class, detailed spectral and imaging analyses can be performed.

astro-ph.SR↗

IDeF-X HD: a CMOS ASIC for the readout of Cd(Zn)Te Detectors for space-borne applications

IDeF-X HD is a 32-channel analog front-end with self-triggering capability optimized for the readout of 16 x 16 pixels CdTe or CdZnTe pixelated detectors to build low power micro gamma camera. IDeF-X HD has been designed in the standard AMS CMOS 0.35 microns process technology. Its power consumption is 800 micro watt per channel. The dynamic range of the ASIC can be extended to 1.1 MeV thanks to the in-channel adjustable gain stage. When no detector is connected to the chip and without input current, a 33 electrons rms ENC level is achieved after shaping with 10.7 micro seconds peak time. Spectroscopy measurements have been performed with CdTe Schottky detectors. We measured an energy resolution of 4.2 keV FWHM at 667 keV (137-Cs) on a mono-pixel configuration. Meanwhile, we also measured 562 eV and 666 eV FWHM at 14 keV and 60 keV respectively (241-Am) with a 256 small pixel array and a low detection threshold of 1.2 keV. Since IDeF-X HD is intended for space-borne applications in astrophysics, we evaluated its radiation tolerance and its sensitivity to single event effects. We demonstrated that the ASIC remained fully functional without significant degradation of its performances after 200 krad and that no single event latch-up was detected putting the Linear Energy Transfer threshold above 110 MeV/(mg/cm2). Good noise performance and radiation tolerance make the chip well suited for X-rays energy discrimination and high-energy resolution. The chip is space qualified and flies on board the Solar Orbiter ESA mission launched in 2020.

astro-ph.IM↗

Origin of the in-orbit instrumental background of the Hard X-ray Imager onboard Hitomi

Understanding and reducing the in-orbit instrumental backgrounds are essential to achieving high sensitivity in hard X-ray astronomical observations. The observational data of the Hard X-ray Imager (HXI) on board the Hitomi satellite provides useful information on the background components, owing to its multi-layer configuration with different atomic numbers: the HXI consists of a stack of four layers of Si (Z = 14) detectors and one layer of CdTe (Z = 48, 52) detector surrounded by well-type BGO (Bi4Ge3O12) active shields. Based on the observational data, the backgrounds of top Si layer, the three underlying Si layers, and the CdTe layer are inferred to be dominated by different components, namely, low-energy electrons, albedo neutrons, and proton-induced radioactivation, respectively. Monte Carlo simulations of the in-orbit background of the HXI reproduce the observed background spectrum of each layer well, thereby verifying the above hypothesis quantitatively. In addition, we suggest the inclusion of an electron shield to reduce the background.

astro-ph.IM↗

Optimal X-ray filters for EDXRF analysis

This work presents a semi-analytical approach to answer the question of optimal beam filtering in the case of EDXRF measurements with an X-ray tube. A collection of programs, called xfilter, is presented that is capable to find the optimal filter material, the optimal filter thickness, and the optimal scattering angle, for all possible combinations of trace elements, target materials, and tube voltages. The concepts of the calculations are introduced in a general manner and demonstrated with a specific example, the detection of gold K_alpha1 XRF within human tissue. Comparing the calculation results and an EDXRF measurement shows excellent agreement.

physics.ins-det↗

The enhanced X-ray Timing and Polarimetry mission - eXTP

In this paper we present the enhanced X-ray Timing and Polarimetry mission - eXTP. eXTP is a space science mission designed to study fundamental physics under extreme conditions of density, gravity and magnetism. The mission aims at determining the equation of state of matter at supra-nuclear density, measuring effects of QED, and understanding the dynamics of matter in strong-field gravity. In addition to investigating fundamental physics, eXTP will be a very powerful observatory for astrophysics that will provide observations of unprecedented quality on a variety of galactic and extragalactic objects. In particular, its wide field monitoring capabilities will be highly instrumental to detect the electro-magnetic counterparts of gravitational wave sources. The paper provides a detailed description of: (1) the technological and technical aspects, and the expected performance of the instruments of the scientific payload; (2) the elements and functions of the mission, from the spacecraft to the ground segment.

astro-ph.IM↗

Detection of polarized gamma-ray emission from the Crab nebula with Hitomi Soft Gamma-ray Detector

We present the results from the Hitomi Soft Gamma-ray Detector (SGD) observation of the Crab nebula. The main part of SGD is a Compton camera, which in addition to being a spectrometer, is capable of measuring polarization of gamma-ray photons. The Crab nebula is one of the brightest X-ray / gamma-ray sources on the sky, and, the only source from which polarized X-ray photons have been detected. SGD observed the Crab nebula during the initial test observation phase of Hitomi. We performed the data analysis of the SGD observation, the SGD background estimation and the SGD Monte Carlo simulations, and, successfully detected polarized gamma-ray emission from the Crab nebula with only about 5 ks exposure time. The obtained polarization fraction of the phase-integrated Crab emission (sum of pulsar and nebula emissions) is (22.1 $\pm$ 10.6)% and, the polarization angle is 110.7$^o$ + 13.2 / $-$13.0$^o$ in the energy range of 60--160 keV (The errors correspond to the 1 sigma deviation). The confidence level of the polarization detection was 99.3%. The polarization angle measured by SGD is about one sigma deviation with the projected spin axis of the pulsar, 124.0$^o$ $\pm$0.1$^o$.

astro-ph.HE↗

The Large Area Detector onboard the eXTP mission

The eXTP (enhanced X-ray Timing and Polarimetry) mission is a major project of the Chinese Academy of Sciences (CAS) and China National Space Administration (CNSA) currently performing an extended phase A study and proposed for a launch by 2025 in a low-earth orbit. The eXTP scientific payload envisages a suite of instruments (Spectroscopy Focusing Array, Polarimetry Focusing Array, Large Area Detector and Wide Field Monitor) offering unprecedented simultaneous wide-band X-ray spectral, timing and polarimetry sensitivity. A large European consortium is contributing to the eXTP study and it is expected to provide key hardware elements, including a Large Area Detector (LAD). The LAD instrument for eXTP is based on the design originally proposed for the LOFT mission within the ESA context. The eXTP/LAD envisages a deployed 3.4 m2 effective area in the 2-30 keV energy range, achieved through the technology of the large-area Silicon Drift Detectors - offering a spectral resolution of up to 200 eV FWHM at 6 keV - and of capillary plate collimators - limiting the field of view to about 1 degree. In this paper we provide an overview of the LAD instrument design, including new elements with respect to the earlier LOFT configuration.

astro-ph.IM↗

In-orbit performance and calibration of the Hard X-ray Imager onboard Hitomi (ASTRO-H)

The Hard X-ray Imager (HXI) onboard Hitomi (ASTRO-H) is an imaging spectrometer covering hard X-ray energies of 5-80 keV. Combined with the hard X-ray telescope, it enables imaging spectroscopy with an angular resolution of $1^\prime.7$ half-power diameter, in a field of view of $9^\prime\times9^\prime$. The main imager is composed of 4 layers of Si detectors and 1 layer of CdTe detector, stacked to cover wide energy band up to 80 keV, surrounded by an active shield made of BGO scintillator to reduce the background. The HXI started observations 12 days before the Hitomi loss, and successfully obtained data from G21.5$-$0.9, Crab and blank sky. Utilizing these data, we calibrate the detector response and study properties of in-orbit background. The observed Crab spectra agree well with a powerlaw model convolved with the detector response, within 5% accuracy. We find that albedo electrons in specified orbit strongly affect the background of Si top layer, and establish a screening method to reduce it. The background level over the full field of view after all the processing and screening is as low as the pre-flight requirement of $1$-$3\times10^{-4}$ counts s$^{-1}$ cm$^{-2}$ keV$^{-1}$.

astro-ph.IM↗

Modeling of proton-induced radioactivation background in hard X-ray telescopes: Geant4-based simulation and its demonstration by Hitomi's measurement in a low Earth orbit

Hard X-ray astronomical observatories in orbit suffer from a significant amount of background due to radioactivation induced by cosmic-ray protons and/or geomagnetically trapped protons. Within the framework of a full Monte Carlo simulation, we present modeling of in-orbit instrumental background dominated by radioactivation. To reduce the computation time required by straightforward simulations of delayed emissions from activated isotopes, we insert a semi-analytical calculation that converts production probabilities of radioactive isotopes by interaction of the primary protons into decay rates at measurement time of all secondary isotopes. Therefore, our simulation method is separated into three steps: (1) simulation of isotope production, (2) semi-analytical conversion to decay rates, and (3) simulation of decays of the isotopes at measurement time. This method is verified by a simple setup that has a CdTe semiconductor detector, and shows a 100-fold improvement in efficiency over the straightforward simulation. The simulation framework was tested against data measured with a CdTe sensor in the Hard X-ray Imager onboard the Hitomi X-ray Astronomy Satellite, which was put into a low Earth orbit with an altitude of 570 km and an inclination of 31 degrees, and thus experienced a large amount of irradiation from geomagnetically trapped protons during its passages through the South Atlantic Anomaly. The simulation is able to treat full histories of the proton irradiation and multiple measurement windows. The simulation results agree very well with the measured data, showing that the measured background is well described by the combination of proton-induced radioactivation of the CdTe detector itself and thick Bi4Ge3O12 scintillator shields, leakage of cosmic X-ray background and albedo gamma-ray radiation, and emissions from naturally contaminated isotopes in the detector system.

astro-ph.IM↗

Hitomi X-ray Observation of the Pulsar Wind Nebula G21.5$-$0.9

We present results from the Hitomi X-ray observation of a young composite-type supernova remnant (SNR) G21.5$-$0.9, whose emission is dominated by the pulsar wind nebula (PWN) contribution. The X-ray spectra in the 0.8-80 keV range obtained with the Soft X-ray Spectrometer (SXS), Soft X-ray Imager (SXI) and Hard X-ray Imager (HXI) show a significant break in the continuum as previously found with the NuSTAR observation. After taking into account all known emissions from the SNR other than the PWN itself, we find that the Hitomi spectra can be fitted with a broken power law with photon indices of $Γ_1=1.74\pm0.02$ and $Γ_2=2.14\pm0.01$ below and above the break at $7.1\pm0.3$ keV, which is significantly lower than the NuSTAR result ($\sim9.0$ keV). The spectral break cannot be reproduced by time-dependent particle injection one-zone spectral energy distribution models, which strongly indicates that a more complex emission model is needed, as suggested by recent theoretical models. We also search for narrow emission or absorption lines with the SXS, and perform a timing analysis of PSR J1833$-$1034 with the HXI and SGD. No significant pulsation is found from the pulsar. However, unexpectedly, narrow absorption line features are detected in the SXS data at 4.2345 keV and 9.296 keV with a significance of 3.65 $σ$. While the origin of these features is not understood, their mere detection opens up a new field of research and was only possible with the high resolution, sensitivity and ability to measure extended sources provided by an X-ray microcalorimeter.

astro-ph.HE↗

Temperature Structure in the Perseus Cluster Core Observed with Hitomi

The present paper investigates the temperature structure of the X-ray emitting plasma in the core of the Perseus cluster using the 1.8--20.0 keV data obtained with the Soft X-ray Spectrometer (SXS) onboard the Hitomi Observatory. A series of four observations were carried out, with a total effective exposure time of 338 ks and covering a central region $\sim7'$ in diameter. The SXS was operated with an energy resolution of $\sim$5 eV (full width at half maximum) at 5.9 keV. Not only fine structures of K-shell lines in He-like ions but also transitions from higher principal quantum numbers are clearly resolved from Si through Fe. This enables us to perform temperature diagnostics using the line ratios of Si, S, Ar, Ca, and Fe, and to provide the first direct measurement of the excitation temperature and ionization temperature in the Perseus cluster. The observed spectrum is roughly reproduced by a single temperature thermal plasma model in collisional ionization equilibrium, but detailed line ratio diagnostics reveal slight deviations from this approximation. In particular, the data exhibit an apparent trend of increasing ionization temperature with increasing atomic mass, as well as small differences between the ionization and excitation temperatures for Fe, the only element for which both temperatures can be measured. The best-fit two-temperature models suggest a combination of 3 and 5 keV gas, which is consistent with the idea that the observed small deviations from a single temperature approximation are due to the effects of projection of the known radial temperature gradient in the cluster core along the line of sight. Comparison with the Chandra/ACIS and the XMM-Newton/RGS results on the other hand suggests that additional lower-temperature components are present in the ICM but not detectable by Hitomi SXS given its 1.8--20 keV energy band.

astro-ph.HE↗