SearcharxivSearch

arXiv subjects

Orlando Cunha

Publications and source records attributed to Orlando Cunha.

3 recordsLinked to original sources

An RPC-PET brain scanner demonstrator: first results

We present first results from a Positron Emission Tomography (PET) scanner demonstrator based on Resistive Plate Chambers and specialized for brain imaging. The device features a 30 cm wide cubic field-of-view and each detector comprises 40 gas gaps with 3D location of the interaction point of the photon. Besides other imagery, we show that the reconstructed image resolution, as evaluated by a hot-rod phantom, is sub-millimetric, which is beyond the state-of-the-art of the standard PET technology for this application.

physics.ins-det

Prototype of an affordable pressure-controlled emergency mechanical ventilator for COVID-19

We present a viable prototype of a simple mechanical ventilator intended as a last resort to ventilate COVID-19 patients. The prototype implements the pressure-controlled continuous mandatory ventilation mode (PC-CMV) with settable breathing rates, inspiration/expiration time ratios and FiO2 modulation. Although safe, the design aims to minimize the use of technical components and those used are common in industry, so its construction may be possible in times of logistical shortage or disruption or in areas with reduced access to technical materials and at a moderate cost, affordable to lower income countries. Most of the device can be manufactured by modest technical means and construction plans are provided.

physics.med-ph

Autonomous RPCs for a Cosmic Ray ground array

We report on the behaviour of Resistive Plate Chambers (RPC) developed for muon detection in ultra-high energy cosmic ray (UHECR) experiments. The RPCs were developed for the MARTA project and were tested on field conditions. These RPCs cover an area of $1.5 \times 1.2\,{m^2}$ and are instrumented with 64 pickup electrodes providing a segmentation better than $20\,$cm. By shielding the detector units with enough slant mass to absorb the electromagnetic component in the air showers, a clean measurement of the muon content is allowed, a concept to be implemented in a next generation of UHECR experiments. The operation of a ground array detector poses challenging demands, as the RPC must operate remotely under extreme environmental conditions, with limited budgets for power and minimal maintenance. The RPC, DAQ, High Voltage and monitoring systems are enclosed in an aluminium-sealed case, providing a compact and robust unit suited for outdoor environments, which can be easily deployed and connected. The RPCs developed at LIP-Coimbra are able to operate using a very low gas flux, which allows running them for few years with a small gas reservoir. Several prototypes have already been built and tested both in the laboratory and outdoors. We report on the most recent tests done in the field that show that the developed RPCs have operated in a stable way for more than 2 years in field conditions.

astro-ph.IM