Searcharxiv⌕ Search

arXiv subjects

P. Ferrero Mancheño

Publications and source records attributed to P. Ferrero Mancheño.

3 recordsLinked to original sources

Demonstrating topological identification capabilities of the NEXT experiment at low pressure

The NEXT-100 detector is a high-pressure xenon time projection chamber utilising electroluminescence amplification for sub-1% FWHM energy resolution and topological discrimination, two key attributes required to achieve the NEXT programme's overarching goal of detecting neutrinoless double beta decay ($0 νββ$). The detector has completed its first physics run at the Laboratorio Subterráneo de Canfranc (LSC), with xenon at a pressure of $\sim$4 bar. In this paper we report on the first validation of NEXT-100's topological performance and present the first topological analysis conducted at low pressure within the detector programme. A Monte Carlo study characterising the effects of pressure on track topology is presented, with qualitative agreement observed in data. We then demonstrate the topological discrimination capabilities for $0νββ$-like events from $^{208}$Tl decays using a cut-based method considered the 'baseline' in NEXT's topological programme, upon which all future analyses will improve. The analysis described applies a set of selection cuts before implementing a background discrimination algorithm that yields a reported signal efficiency for double-electron tracks and background acceptance for single-electron tracks of 75.6 $\pm$ 1.9 (stat.) $^{+3.4}_{-4.1}$ (syst.) % and 14.7 $\pm$ 0.4 (stat.) $^{+0.7}_{-0.8}$ (syst.) %. These results demonstrate the excellent topological discrimination capabilities of the NEXT-100 detector in line with NEXT-White, which achieved a signal efficiency and background acceptance of 71.6 $\pm$ 1.5 (stat.) $\pm$ 0.3 (syst.) % and 20.6 $\pm$ 0.4 (stat.) $\pm$ 0.3 (syst.) % respectively.

hep-ex↗

Radon-induced backgrounds in the NEXT-100 experiment

The NEXT-100 detector at the LSC aims at the first competitive search for the \bbnonu decay using a high-pressure \Xe{136} electroluminescent time projection chamber. The first low-background run of NEXT-100 at 3.95 bar has been devoted to the measurement of the radon-induced backgrounds impacting this search. The contributions from both the internal and external airborne radon have been evaluated. The internal \Rn{222} activity is found to be (0.95$\pm$0.04(stat)$\pm$0.09(sys)) Bq/m$^3$, while no traces of \Rn{220} have been observed. Most of the \Rn{222} progeny plate-out on the surface of the cathode of the detector, leading to a rate of Rn-induced \Bi{214} of (0.97$\pm$0.05(stat)$\pm$0.10(sys)) Hz for visible energies above 400 keV. The corresponding background index in the \bbnonu region of interest is evaluated as (7.3$\pm$1.5(stat)$\pm$0.8(sys))$\times10^{-4}$ counts/(keV$\cdot$kg$\cdot$yr) after selection of the fully contained events. This background index is reduced to $\sim$4$\times10^{-5}$ counts/(keV$\cdot$kg$\cdot$yr) by applying a topological selection requiring only one double-electron-like track in the events. This value is one order of magnitude below the total radiogenic background expectation in NEXT-100. By analyzing the correlation of the airborne radon activity and the measured rate of events in NEXT-100, it is concluded that the detector operates in a virtually radon-free environment thanks to the radon abatement system of the LSC.

hep-ex↗

Electroluminescence Yield Measurements in Xenon Gas with the NEXT-DEMO++ Detector

The NEXT-DEMO++ detector, a high-pressure xenon gas time projection chamber serving as a prototype for the NEXT-100 experiment, was used to measure the electroluminescence (EL) yield as a function of reduced electric field ($E/p$) across pressures from 2.0 to 9.4 bar, utilizing the 41.5 keV de-excitation peak of $^{83m}$Kr. These measurements were made to examine the pressure dependence of the slope of the reduced EL yield $Y/p$, which has shown inconsistencies in the literature. The reduced yield was fitted with a linear model, revealing a modest ($\sim$5%) change in slope, beginning around 5 bar and increasing with pressure up to 9.4 bar.

physics.ins-det↗