Searcharxiv⌕ Search

arXiv subjects

P. Geltenbort

Publications and source records attributed to P. Geltenbort.

At least 55 records · Page 3Linked to original sources

A prestorage method to measure neutron transmission of ultracold neutron guides

There are worldwide efforts to search for physics beyond the Standard Model of particle physics. Precision experiments using ultracold neutrons (UCN) require very high intensities of UCN. Efficient transport of UCN from the production volume to the experiment is therefore of great importance. We have developed a method using prestored UCN in order to quantify UCN transmission in tubular guides. This method simulates the final installation at the Paul Scherrer Institute's UCN source where neutrons are stored in an intermediate storage vessel serving three experimental ports. This method allowed us to qualify UCN guides for their intended use and compare their properties.

physics.ins-det↗

Measurement of a false electric dipole moment signal from $^{199}$Hg atoms exposed to an inhomogeneous magnetic field

We report on the measurement of a Larmor frequency shift proportional to the electric-field strength for $^{199}{\rm Hg}$ atoms contained in a volume permeated with aligned magnetic and electric fields. This shift arises from the interplay between the inevitable magnetic field gradients and the motional magnetic field. The proportionality to electric-field strength makes it apparently similar to an electric dipole moment (EDM) signal, although unlike an EDM this effect is P- and T-conserving. We have used a neutron magnetic resonance EDM spectrometer, featuring a mercury co-magnetometer and an array of external cesium magnetometers, to measure the shift as a function of the applied magnetic field gradient. Our results are in good agreement with theoretical expectations.

physics.atom-ph↗

Spectrometer for new gravitational experiment with UCN

We describe an experimental installation for a new test of the weak equivalence principle for neutron. The device is a sensitive gravitational spectrometer for ultra-cold neutrons allowing to precisely compare the gain in kinetic energy of free falling neutrons to quanta of energy ${\hbar}Ω$ transferred to the neutron via a non stationary device, i.e. a quantum modulator. The results of first test experiments indicate a collection rate allowing measurements of the factor of equivalence $ { γ}$ with a statistical uncertainty in the order of $5{\times}10^{-3}$ per day. A number of systematic effects were found, which partially can be easily corrected. For the elimination of others more detailed investigations and analysis are needed. Some possibilities to improve the device are also discussed.

physics.ins-det↗

Measurement of the neutron lifetime with ultra-cold neutrons stored in a magneto-gravitational trap

We report a new measurement of the neutron lifetime using ultra-cold neutrons stored in a magneto-gravitational trap made of permanent magnets. Neutrons surviving in the trap after fixed storage times have been counted and the trap losses have continuously been monitored during storage by detecting neutrons leaking from the trap. The value of the neutron lifetime resulting from this measurement is $τ_n=(878.3\pm1.9)$s. It is the most precise measurement of the neutron lifetime obtained with magnetically stored neutrons.

nucl-ex↗

A measurement of the neutron to 199Hg magnetic moment ratio

The neutron gyromagnetic ratio has been measured relative to that of the 199Hg atom with an uncertainty of 0.8 ppm. We employed an apparatus where ultracold neutrons and mercury atoms are stored in the same volume and report the result $γ_{\rm n}/γ_{\rm Hg} = 3.8424574(30)$.

nucl-ex↗

New measurements of neutron electric dipole moment with double chamber EDM spectrometer

The article presents results on neutron electric dipole moment measurements (EDM), made by ILL reactor using PNPI experimental installation. Double chamber magnetic resonance spectrometer with prolonged holding of ultra cold neutrons has been employed. The obtained results at 90% confidence level determine the upper limit for EDM neutron quantity equal to $|d_n| < 5.5 \cdot 10^{-26}$ e$ \cdot$cm.

nucl-ex↗

Gravity Resonance Spectroscopy Constrains Dark Energy and Dark Matter Scenarios

We report on precision resonance spectroscopy measurements of quantum states of ultracold neutrons confined above the surface of a horizontal mirror by the gravity potential of the Earth. Resonant transitions between several of the lowest quantum states are observed for the first time. These measurements demonstrate, that Newton's inverse square law of Gravity is understood at micron distances on an energy scale of~$10^{-14}$~eV. At this level of precision we are able to provide constraints on any possible gravity-like interaction. In particular, a dark energy chameleon field is excluded for values of the coupling constant~$β> 5.8\times10^8$ at~95% confidence level~(C.L.), and an attractive (repulsive) dark matter axion-like spin-mass coupling is excluded for the coupling strength $g_sg_p > 3.7\times10^{-16}$~($5.3\times10^{-16}$)~at a Yukawa length of~$λ= 20$~{\textmu}m~(95% (C.L.).

gr-qc↗

Vectorial velocity filter for ultracold neutrons based on a surface-disordered mirror system

We perform classical three-dimensional Monte Carlo simulations of ultracold neutrons scattering through an absorbing-reflecting mirror system in the Earth's gravitational field. We show that the underlying mixed phase space of regular skipping motion and random motion due to disorder scattering can be exploited to realize a vectorial velocity filter for ultracold neutrons. The absorbing-reflecting mirror system proposed allows beams of ultracold neutrons with low angular divergence to be formed. The range of velocity components can be controlled by adjusting the geometric parameters of the system. First experimental tests of its performance are presented. One potential future application is the investigation of transport and scattering dynamics in confined systems downstream of the filter.

hep-ph↗

Observation of the Spatial Distribution of Gravitationally Bound Quantum States of Ultracold Neutrons and Its Derivation Using the Wigner Function

Ultracold neutrons (UCNs) can be bound by the potential of terrestrial gravity and a reflecting mirror. The wave function of the bound state has characteristic modulations. We carried out an experiment to observe the vertical distribution of the UCNs above such a mirror at Institut Laue-Langevin in 2011. The observed modulation is in good agreement with that prediction by quantum mechanics using the Wigner function. The spatial resolution of the detector system is estimated to be 0.7 micro meter. This is the first observation of gravitationally bound states of UCNs with submicron spatial resolution.

hep-ex↗

New measurements of neutron electric dipole moment

We report a new measurement of the neutron electric dipole moment with the PNPI EDM spectrometer using the ultracold neutron source PF2 at the research reactor of the ILL. Its first results can be interpreted as a limit on the neutron EDM of $|d_{\rm n}| < 5.5 \times 10^{-26} \rm{e} \cdot \rm{cm}$ (90% confidence level).

nucl-ex↗

Storage of ultracold neutrons in the UCN$τ$ magneto-gravitational trap

The UCN$τ$ experiment is designed to measure the lifetime $τ_{n}$ of the free neutron by trapping ultracold neutrons (UCN) in a magneto-gravitational trap. An asymmetric bowl-shaped NdFeB magnet Halbach array confines low-field-seeking UCN within the apparatus, and a set of electromagnetic coils in a toroidal geometry provide a background "holding" field to eliminate depolarization-induced UCN loss caused by magnetic field nodes. We present a measurement of the storage time $τ_{store}$ of the trap by storing UCN for various times, and counting the survivors. The data are consistent with a single exponential decay, and we find $τ_{store}=860\pm19$ s: within $1 σ$ of current global averages for $τ_{n}$. The storage time with the holding field deactiveated is found to be $τ_{store}=470 \pm 160$ s; this decreased storage time is due to the loss of UCN which undergo Majorana spin-flips while being stored. We discuss plans to increase the statistical sensitivity of the measurement and investigate potential systematic effects.

physics.ins-det↗

Investigating solid $α-^{15}$N$_{2}$ as a new source of ultra-cold neutrons

The dynamical structure factor of solid $^{15}$N$_{2}$ in the $α$ phase ($T<35$K) is measured at the IN4 time-of-flight spectrometer at the Institut Laue Langevin, and the potential performance of this substance as a UCN converter is assessed. The cross-section to down-scatter neutrons to ultra-cold neutron energies is determined as a function of incident energy, as well as the up-scattering mean free path. The UCN production cross-section is found to be approximately 20% of that of deuterium. However, UCN with energy 181 neV have an up-scattering mean free path of 46 cm at $T=5.9$ K, which is $\sim20$ times larger than deuterium. Therefore, a large volume $α-^{15}$N$_{2}$ source may produce an improved UCN density if sufficient isotopic purity can be achieved.

nucl-ex↗

Apparatus for Measurement of the Electric Dipole Moment of the Neutron using a Cohabiting Atomic-Mercury Magnetometer

A description is presented of apparatus used to carry out an experimental search for an electric dipole moment of the neutron, at the Institut Laue-Langevin (ILL), Grenoble. The experiment incorporated a cohabiting atomic-mercury magnetometer in order to reduce spurious signals from magnetic field fluctuations. The result has been published in an earlier letter; here, the methods and equipment used are discussed in detail.

physics.ins-det↗

Precision Measurement of the Neutron Beta-Decay Asymmetry

A new measurement of the neutron $β$-decay asymmetry $A_0$ has been carried out by the UCNA collaboration using polarized ultracold neutrons (UCN) from the solid deuterium UCN source at the Los Alamos Neutron Science Center (LANSCE). Improvements in the experiment have led to reductions in both statistical and systematic uncertainties leading to $A_0 = -0.11954(55)_{\rm stat.}(98)_{\rm syst.}$, corresponding to the ratio of axial-vector to vector coupling $λ\equiv g_A/g_V = -1.2756(30)$.

nucl-ex↗

A quantized frequency reference in the short-ranged gravity potential and its application for dark matter and dark energy searches

The evidence for the observation of the Higgs spin-0-boson as a manifestation of a scalar field provides the missing corner stone for the standard model of particles (SM). However, the SM fails to explain the non-visible but gravitationally active part of the universe. Its nature is unknown but the confirmation of a scalar Higgs is giving a boost to scalar-field-theories. So far gravity experiments and observations performed at different distances find no deviation from Newton's gravity law. Therefore dark energy must possess a screening mechanism which suppresses the scalar-mediated fifth force. Our line of attack is a novel gravity experiment with neutrons based on a quantum interference technique. The spectroscopic measurement of quantum states on resonances with an external coupling makes this a powerful search for dark matter and dark energy contributions in the universe. Quantum states in the gravity potential are intimately related to other scalar field or spin-0-bosons if they exist. If the reason is that some undiscovered particle interact with a neutron, this results in a measurable energy shift of quantum states in the gravity potential, because for neutrons the screening effect is absent. We use Gravity Resonance Spectroscopy to measure the energy splitting at the highest level of precision, providing a constraint on any possible new interaction. We obtain a sensitivity of 10^-14 eV. We set an experimental limit on any fifth force, in particular on parameter β<2x10^9 at n=3 for the scalar chameleon field, which is improved by a factor of 100 compared to our previous experiment and five orders of magnitude better than from precision tests of atomic spectra. The pseudoscalar axion coupling is constrained to gsgp/\hbar c<3x10^-16 at 20μm, which is an improvement by a factor of 30. These results indicate that gravity is understood at this improved level of precision.

hep-ex↗

Measurement of the neutron $β$-asymmetry parameter $A_0$ with ultracold neutrons

We present a detailed report of a measurement of the neutron $β$-asymmetry parameter $A_0$, the parity-violating angular correlation between the neutron spin and the decay electron momentum, performed with polarized ultracold neutrons (UCN). UCN were extracted from a pulsed spallation solid deuterium source and polarized via transport through a 7-T magnetic field. The polarized UCN were then transported through an adiabatic-fast-passage spin-flipper field region, prior to storage in a cylindrical decay volume situated within a 1-T $2 \times 2π$ solenoidal spectrometer. The asymmetry was extracted from measurements of the decay electrons in multiwire proportional chamber and plastic scintillator detector packages located on both ends of the spectrometer. From an analysis of data acquired during runs in 2008 and 2009, we report $A_0 = -0.11966 \pm 0.00089_{-0.00140} ^{+0.00123}$, from which we extract a value for the ratio of the weak axial-vector and vector coupling constants of the nucleon, $λ= g_A/g_V = -1.27590 \pm 0.00239_{-0.00377}^{+0.00331}$. Complete details of the analysis are presented.

nucl-ex↗

Mirrors for slow neutrons from holographic nanoparticle-polymer free-standing film-gratings

We report on successful tests of holographically arranged grating-structures in nanoparticle-polymer composites in the form of 100 microns thin free-standing films, i.e. without sample containers or covers that could cause unwanted absorption/incoherent scattering of very-cold neutrons. Despite their large diameter of 2 cm, the flexible materials are of high optical quality and yield mirror-like reflectivity of about 90% for neutrons of 4.1 nm wavelength.

cond-mat.mtrl-sci↗

Diffraction of slow neutrons by holographic SiO_2 nanoparticle-polymer composite gratings

Diffraction experiments with holographic gratings recorded in SiO$_2$ nanoparticle-polymer composites have been carried out with slow neutrons. The influence of parameters such as nanoparticle concentration, grating thickness and grating spacing on the neutron-optical properties of such materials has been tested. Decay of the grating structure along the sample depth due to disturbance of the recording process becomes an issue at grating thicknesses of about 100 microns and larger. This limits the achievable diffraction efficiency for neutrons. As a solution to this problem, the Pendellösung interference effect in holographic gratings has been exploited to reach a diffraction efficiency of 83% for very cold neutrons.

cond-mat.mtrl-sci↗