Searcharxiv⌕ Search

arXiv subjects

P. Geltenbort

Publications and source records attributed to P. Geltenbort.

At least 37 records · Page 2Linked to original sources

Performance of the upgraded ultracold neutron source at Los Alamos National Laboratory and its implication for a possible neutron electric dipole moment experiment

The ultracold neutron (UCN) source at Los Alamos National Laboratory (LANL), which uses solid deuterium as the UCN converter and is driven by accelerator spallation neutrons, has been successfully operated for over 10 years, providing UCN to various experiments, as the first production UCN source based on the superthermal process. It has recently undergone a major upgrade. This paper describes the design and performance of the upgraded LANL UCN source. Measurements of the cold neutron spectrum and UCN density are presented and compared to Monte Carlo predictions. The source is shown to perform as modeled. The UCN density measured at the exit of the biological shield was $184(32)$ UCN/cm$^3$, a four-fold increase from the highest previously reported. The polarized UCN density stored in an external chamber was measured to be $39(7)$ UCN/cm$^3$, which is sufficient to perform an experiment to search for the nonzero neutron electric dipole moment with a one-standard-deviation sensitivity of $σ(d_n) = 3\times 10^{-27}$ $e\cdot$cm.

physics.ins-det↗

Neutron lifetime measurements with the big gravitational trap for ultracold neutrons

Neutron lifetime is one of the most important physical constants which determines parameters of the weak interaction and predictions of primordial nucleosynthesis theory. There remains the unsolved problem of a 3.9σ discrepancy between measurements of this lifetime using neutrons in beams and those with stored neutrons (UCN). In our experiment we measure the lifetime of neutrons trapped by Earth's gravity in an open-topped vessel. Two configurations of the trap geometry are used to change the mean frequency of UCN collisions with the surfaces - this is achieved by plunging an additional surface into the trap without breaking the vacuum. The trap walls are coated with a hydrogen-less fluorine-containing polymer to reduce losses of UCN. The stability of this coating to multiple thermal cycles between 80 K and 300 K was tested. At 80 K, the probability of UCN loss due to collisions with the trap walls is just 1.5% of the probability of beta-decay. The free neutron lifetime is determined by extrapolation to an infinitely large trap with zero collision frequency. The result of these measurements is 881.5 +/- 0.7_stat +/- 0.6_syst s which is consistent with the conventional value of 880.2 +/- 1.0 s presented by the Particle Data Group. Future prospects for this experiment are in further cooling to 10 K which will lead to an improved accuracy of measurement. In conclusion we present an analysis of currently-available data on various measurements of the neutron lifetime.

nucl-ex↗

New experimental limits on neutron - mirror neutron oscillations in the presence of mirror magnetic field

Present probes do not exclude that the neutron ($n$) oscillation into mirror neutron ($n'$), a sterile state exactly degenerate in mass with the neutron, can be a very fast process, in fact faster than the neutron decay itself. This process is sensitive to the magnetic field. Namely, if the mirror magnetic field $\vec{B}'$ exists at the Earth, $n-n'$ oscillation probability can be suppressed or resonantly amplified by the applied magnetic field $\vec{B}$, depending on its strength and on the angle $β$ between $\vec{B}$ and $\vec{B}'$. We present the results of ultra-cold neutron storage measurements aiming to check the anomalies observed in previous experiments which could be a signal for $n-n'$ oscillation in the presence of mirror magnetic field $B'\sim 0.1$~G. Analyzing the experimental data on neutron loses, we obtain a new lower limit on $n-n'$ oscillation time $τ_{nn'} > 17$ s (95 % C.L.) for any $B'$ between 0.08 and 0.17 G, and $τ_{nn'}/\sqrt{\cosβ} > 27 $s (95 % C.L.) for any $B'$ in the interval ($0.06\div0.25$) G.

hep-ex↗

Search for axion-like dark matter through nuclear spin precession in electric and magnetic fields

We report on a search for ultra-low-mass axion-like dark matter by analysing the ratio of the spin-precession frequencies of stored ultracold neutrons and $^{199}$Hg atoms for an axion-induced oscillating electric dipole moment of the neutron and an axion-wind spin-precession effect. No signal consistent with dark matter is observed for the axion mass range $10^{-24}~\textrm{eV} \le m_a \le 10^{-17}~\textrm{eV}$. Our null result sets the first laboratory constraints on the coupling of axion dark matter to gluons, which improve on astrophysical limits by up to 3 orders of magnitude, and also improves on previous laboratory constraints on the axion coupling to nucleons by up to a factor of 40.

hep-ph↗

First direct constraints on Fierz interference in free neutron $β$ decay

Precision measurements of free neutron $β$-decay have been used to precisely constrain our understanding of the weak interaction. However the neutron Fierz interference term $b_n$, which is particularly sensitive to Beyond-Standard-Model tensor currents at the TeV scale, has thus far eluded measurement. Here we report the first direct constraints on this term, finding $b_n = 0.067 \pm 0.005_{\text{stat}} {}^{+0.090}_{- 0.061}{}_{\text{sys}}$, consistent with the Standard Model. The uncertainty is dominated by absolute energy reconstruction and the linearity of the beta spectrometer energy response.

nucl-ex↗

Consistent description of UCN transport properties

We have investigated the diffuse reflection probabilities of Replica guides for ultra-cold neutrons (UCN) using the so-called helium method. For the first time we could establish a consistent description of the diffuse reflection mechanism for different lengths of the guide system. The transmission of the guides is measured depending on the helium pressure inside of the guides. A series of simulations was done to reproduce the experimental data. These simulations showed that a diffuse reflection probability of $d = (3.0 \pm 0.5) \cdot 10^{-2}$ sufficiently describes the experimental data.

physics.ins-det↗

Comparison of ultracold neutron sources for fundamental physics measurements

Ultracold neutrons (UCNs) are key for precision studies of fundamental parameters of the neutron and in searches for new CP violating processes or exotic interactions beyond the Standard Model of particle physics. The most prominent example is the search for a permanent electric dipole moment of the neutron (nEDM). We have performed an experimental comparison of the leading UCN sources currently operating. We have used a 'standard' UCN storage bottle with a volume of 32 liters, comparable in size to nEDM experiments, which allows us to compare the UCN density available at a given beam port.

physics.ins-det↗

Ultracold neutron detection with 6Li-doped glass scintillators, NANOSC: a fast ultracold neutron detector for the nEDM experiment at the Paul Scherrer Institute

This paper summarizes the results from measurements aiming to characterize ultracold neutron detection with 6Li-doped glass scintillators. Single GS10 or GS20 scintillators, with a thickness of 100-200 micrometer, fulfill the ultracold neutron detection requirements with an acceptable neutron-gamma discrimination. This discrimination is clearly improved with a stack of two scintillators: a 6Li-depleted glass bonded to a 6Li-enriched glass. The optical contact bonding is used between the scintillators in order to obtain a perfect optical contact. The scintillator's detection efficiency is similar to that of a 3He Strelkov gas detector. Coupled to a digital data acquisition system, counting rates up to a few 10^5 counts/s can be handled. A detector based on such a scintillator stack arrangement was built and has been used in the neutron electric dipole moment experiment at the Paul Scherrer Institute since 2010. Its response for the regular runs of the neutron electric dipole moment experiment is presented.

physics.ins-det↗

Neutron lifetime measurements and effective spectral cleaning with an ultracold neutron trap using a vertical Halbach octupole permanent magnet array

Ultracold neutron (UCN) storage measurements were made in a trap constructed from a 1.3 T Halbach Octupole PErmanent (HOPE) magnet array aligned vertically, using the TES-port of the PF2 source at the Institut Laue-Langevin. A mechanical UCN valve at the bottom of the trap was used for filling and emptying. This valve was covered with Fomblin grease to induce non-specular reflections and was used in combination with a movable polyethylene UCN remover inserted from the top for cleaning of above-threshold UCNs. Loss due to UCN depolarization was suppressed with a minimum 2 mT bias field. Without using the UCN remover, a total storage time constant of $(712 \pm 19)$ s was observed; with the remover inserted for 80 s and used at either 80 cm or 65 cm from the bottom of the trap, time constants of $(824 \pm 32)$ s and $(835 \pm 36)$ s were observed. Combining the latter two values, a neutron lifetime of $τ_{\rm n} = (887 \pm 39)$ s is extracted after primarily correcting for losses at the UCN valve. The time constants of the UCN population during cleaning were observed and compared to calculations based on UCN kinetic theory as well as Monte-Carlo studies. These calculations are used to predict above-threshold populations of $\sim 5\%$, $\sim 0.5\%$ and $\sim 10^{-12}\%$ remaining after cleaning in the no remover, 80~cm remover and 65~cm remover measurements. Thus, by using a non-specular reflector covering the entire bottom of the trap and a remover at the top of the trap, we have established an effective cleaning procedure for removing a major systematic effect in high-precision $τ_{\rm n}$ experiments with magnetically stored UCNs.

nucl-ex↗

Position-sensitive detection of ultracold neutrons with an imaging camera and its implications to spectroscopy

Position-sensitive detection of ultracold neutrons (UCNs) is demonstrated using an imaging charge-coupled device (CCD) camera. A spatial resolution less than 15 $μ$m has been achieved, which is equivalent to an UCN energy resolution below 2 pico-electron-volts through the relation $δE = m_0g δx$. Here, the symbols $δE$, $δx$, $m_0$ and $g$ are the energy resolution, the spatial resolution, the neutron rest mass and the gravitational acceleration, respectively. A multilayer surface convertor described previously is used to capture UCNs and then emits visible light for CCD imaging. Particle identification and noise rejection are discussed through the use of light intensity profile analysis. This method allows different types of UCN spectroscopy and other applications.

physics.ins-det↗

Spectroscopy of ultracold neutrons using diffraction by a moving grating

Spectra of ultracold neutrons that appeared in experiments on neutron diffraction by a moving grating were measured using the time-of-flight Fourier spectrometer. Diffraction lines of five orders were observed simultaneously. The obtained data are in good agreement with the theoretical predictions based on the multiwave dynamical theory of neutron diffraction by a moving grating.

nucl-ex↗

Time-of-flight Fourier UCN spectrometer

We describe a new time-of-flight Fourier spectrometer for investigation of UCN diffraction by a moving grating. The device operates in the regime of a discrete set of modulation frequencies. The results of the first experiments show that the spectrometer may be used for obtaining UCN energy spectra in the energy range of 60$÷$200 neV with a resolution of about 5 neV. The accuracy of determination of the line position was estimated to be several units of $10^{-10}$ eV

physics.ins-det↗

A Gravity of Earth Measurement with a qBOUNCE Experiment

We report a measurement of the local acceleration $g$ with ultracold neutrons based on quantum states in the gravity potential of the Earth. The new method uses resonant transitions between the states $|1> -> |3>$ and for the first time between $|1> -> |4>$. The measurements demonstrate that Newton's Inverse Square Law of Gravity is understood at micron distances at an energy level of $10^{-14}$ eV with $\frac{Δg}{g}=4\times10^{-3}$. The results provide constraints on any possible gravity-like interaction at a micrometer interaction range. In particular, a dark energy candidate, the chameleon field is restricted to $β<6.9\times10^{6}$ for $n=2$ (95\% C.L.).

hep-ex↗

Deuterated polyethylene coatings for ultra-cold neutron applications

We report on the fabrication and use of deuterated polyethylene (dPE) as a coating material for ultra-cold neutron (UCN) storage and transport. The Fermi potential has been determined to be 214~neV and the wall loss coefficient $η$ is 1.3$\cdot$10$^4$ per wall collision. The coating technique allows for a wide range of applications and new possibilities in this field of physics. In particular, flexible and quasi-massless UCN guides with slit-less shutters and slit-less UCN storage volumes become possible. These properties enable the use in next-generation measurements of the electric dipole moment of the neutron.

physics.ins-det↗

A Revised Experimental Upper Limit on the Electric Dipole Moment of the Neutron

We present for the first time a detailed and comprehensive analysis of the experimental results that set the current world sensitivity limit on the magnitude of the electric dipole moment (EDM) of the neutron. We have extended and enhanced our earlier analysis to include recent developments in the understanding of the effects of gravity in depolarizing ultracold neutrons (UCN); an improved calculation of the spectrum of the neutrons; and conservative estimates of other possible systematic errors, which are also shown to be consistent with more recent measurements undertaken with the apparatus. We obtain a net result of $d_\mathrm{n} = -0.21 \pm 1.82 \times10^{-26}$ $e$cm, which may be interpreted as a slightly revised upper limit on the magnitude of the EDM of $3.0 \times10^{-26}$ $e$cm (90% CL) or $ 3.6 \times10^{-26}$ $e$cm (95% CL). This paper is dedicated by the remaining authors to the memory of Prof. J. Michael Pendlebury.

hep-ex↗

A device for simultaneous spin analysis of ultracold neutrons

We report on the design and first tests of a device allowing for measurement of ultracold neutrons polarisation by means of the simultaneous analysis of the two spin components. The device was developed in the framework of the neutron electric dipole moment experiment at the Paul Scherrer Institute. Individual parts and the entire newly built system have been characterised with ultracold neutrons. The gain in statistical sensitivity obtained with the simultaneous spin analyser is $(18.2\pm6.1)\%$ relative to the former sequential analyser under nominal running conditions.

physics.ins-det↗

Gravity experiments with ultracold neutrons and the qBounce experiment

This work focuses on the control and understanding of a gravitationally interacting elementary quantum system. It offers a new way of looking at gravitation based on quantum interference: an ultracold neutron, a quantum particle, as an object and as a tool. The ultracold neutron as a tool reflects from a mirror in well-defined quantum states in the gravity potential of the earth allowing to apply the concept of gravity resonance spectroscopy (GRS). GRS relies on frequency measurements, which provide a spectacular sensitivity.

physics.ins-det↗

Gravitational Depolarization of Ultracold Neutrons: Comparison with Data

We compare the expected effects of so-called gravitationally enhanced depolarization of ultracold neutrons to measurements carried out in a spin-precession chamber exposed to a variety of vertical magnetic-field gradients. In particular, we have investigated the dependence upon these field gradients of spin depolarization rates and also of shifts in the measured neutron Larmor precession frequency. We find excellent qualitative agreement, with gravitationally enhanced depolarization accounting for several previously unexplained features in the data.

physics.ins-det↗