SearcharxivSearch

arXiv subjects

P. Giacomelli

Publications and source records attributed to P. Giacomelli.

15 recordsLinked to original sources

Efficiency measurements of GEM GE1/1 chambers in the upgraded CMS Endcap Muon System using 2023 collision data at $\sqrt{s}=13.6$ TeV

The CMS experiment at the Large Hadron Collider employs Gas Electron Multiplier (GEM) detectors, a technology based on gaseous ionization, as one of the muon detectors. The muon spectrometer is being upgraded to handle the increased muon flux in the forward region. This study analyzes muon detection efficiency in the GE1/1 triple-GEM detector, using 2023 proton-proton collision data at $\sqrt{s}=13.6$ TeV. A dataset enriched with muons from Z boson decay, with a total recorded luminosity of 17.8 fb$^{-1}$ has been used for this study. The detection efficiency of 137 GEM detectors are measured using muon trajectories established using other detectors in the tracking and muon systems, without use of the GEM detectors. The average efficiency of 137 GEM detectors is $\sim$93.3$\%$. A subset of 108 detectors that had no shorts were operated at the nominal HV working point with average efficiency of $\sim$96$\%$. Efficiency is found to be unaffected by the number of p-p interactions per bunch crossing (pile-up).

hep-ex

Exposing a fibre-based dual-readout calorimeter to a positron beam

A prototype of a dual-readout calorimeter using brass capillary tubes surrounding scintillating and clear plastic optical fibres was tested using beams of particles with energies between 10 and 100 GeV produced by the CERN SPS. The scope of the test was to characterise the performance of the tube-based detector response to positrons in terms of linearity, energy resolution, and lateral granularity. After calibrating the detector and processing the output signal to correct for the energy dependency on the particle impact point, the linearity of the measurement was found to be better than 1\%. The positron response was compared to that predicted by a Geant4-based simulation, finding good agreement both in terms of energy resolution and shower profile. The detector resolution was estimated to be well described by a stochastic term of 14.5\% with a negligible constant term.

physics.ins-det

The Future Circular Collider: a Summary for the US 2021 Snowmass Process

In this white paper for the 2021 Snowmass process, we give a description of the proposed Future Circular Collider (FCC) project and its physics program. The paper summarizes and updates the discussion submitted to the European Strategy on Particle Physics. After construction of an approximately 90 km tunnel, an electron-positron collider based on established technologies allows world-record instantaneous luminosities at center-of-mass energies from the Z resonance up to tt thresholds, enabling a rich set of fundamental measurements including Higgs couplings determinations at the sub percent level, precision tests of the weak and strong forces, and searches for new particles, including dark matter, both directly and via virtual corrections or mixing. Among other possibilities, the FCC-ee will be able to (i) indirectly discover new particles coupling to the Higgs and/or electroweak bosons up to scales around 7 and 50 TeV, respectively; (ii) perform competitive SUSY tests at the loop level in regions not accessible at the LHC; (iii) study heavy-flavor and tau physics in ultra-rare decays beyond the LHC reach, and (iv) achieve the best potential in direct collider searches for dark matter, sterile neutrinos, and axion-like particles with masses up to around 90 GeV. The tunnel can then be reused for a proton-proton collider, establishing record center-of-mass collision energy, allowing unprecedented reach for direct searches for new particles up to the around 50 TeV scale, and a diverse program of measurements of the Standard Model and Higgs boson, including a precision measurement of the Higgs self-coupling, and conclusively testing weakly-interacting massive particle scenarios of thermal relic dark matter.

hep-ex

Quality Control of Mass-Produced GEM Detectors for the CMS GE1/1 Muon Upgrade

The series of upgrades to the Large Hadron Collider, culminating in the High Luminosity Large Hadron Collider, will enable a significant expansion of the physics program of the CMS experiment. However, the accelerator upgrades will also make the experimental conditions more challenging, with implications for detector operations, triggering, and data analysis. The luminosity of the proton-proton collisions is expected to exceed $2-3\times10^{34}$~cm$^{-2}$s$^{-1}$ for Run 3 (starting in 2022), and it will be at least $5\times10^{34}$~cm$^{-2}$s$^{-1}$ when the High Luminosity Large Hadron Collider is completed for Run 4. These conditions will affect muon triggering, identification, and measurement, which are critical capabilities of the experiment. To address these challenges, additional muon detectors are being installed in the CMS endcaps, based on Gas Electron Multiplier technology. For this purpose, 161 large triple-Gas Electron Multiplier detectors have been constructed and tested. Installation of these devices began in 2019 with the GE1/1 station and will be followed by two additional stations, GE2/1 and ME0, to be installed in 2023 and 2026, respectively. The assembly and quality control of the GE1/1 detectors were distributed across several production sites around the world. We motivate and discuss the quality control procedures that were developed to standardize the performance of the detectors, and we present the final results of the production. Out of 161 detectors produced, 156 detectors passed all tests, and 144 detectors are now installed in the CMS experiment. The various visual inspections, gas tightness tests, intrinsic noise rate characterizations, and effective gas gain and response uniformity tests allowed the project to achieve this high success rate.

physics.ins-det

MPGDs for tracking and Muon detection at future high energy physics colliders

In the next years, the energy and intensity frontiers of the experimental Particle Physics will be pushed forward with the upgrade of existing accelerators (LHC at CERN) and the envisaged construction of new machines at energy scales up to hundreds TeV or with unprecedented intensity (FCC-hh, FCC-ee, ILC, Muon Collider). Large size, cost-effective, high-efficiency detection systems in high background environments are required in order to accomplish the physics program. MPGDs offer a diversity of technologies that allow them to meet the required performance challenges at future facilities thanks to the specific advantages that each technology provides. MPGDs allow stable operation, with environmentally friendly gas mixtures, at very high background particle flux with high detection efficiency and excellent spatial resolution. These features make MPGD one of the primary choices as precise muon tracking and trigger system in general-purpose detectors at future HEP colliders. In addition, the low material budget and the flexibility of the base material make MPGDs suitable for the development of very light, full cylindrical fine tracking inner trackers at lepton colliders. On-going R&Ds aim at pushing the detector performance at the limits of each technology. We are working in continuing to consolidate the construction and stable operation of large-size detectors, able to cope with large particle fluxes. In this white paper, we describe some of the most prominent MPGD technologies, their performance measurements, the challenges faced in the most recent applications, and the areas of improvement towards efficient tracking and Muon detection at future high energy physics colliders.

physics.ins-det

Performance of a Triple-GEM Demonstrator in $pp$ Collisions at the CMS Detector

After the Phase-2 high-luminosity upgrade to the Large Hadron Collider (LHC), the collision rate and therefore the background rate will significantly increase, particularly in the high $η$ region. To improve both the tracking and triggering of muons, the Compact Muon Solenoid (CMS) Collaboration plans to install triple-layer Gas Electron Multiplier (GEM) detectors in the CMS muon endcaps. Demonstrator GEM detectors were installed in CMS during 2017 to gain operational experience and perform a preliminary investigation of detector performance. We present the results of triple-GEM detector performance studies performed in situ during normal CMS and LHC operations in 2018. The distribution of cluster size and the efficiency to reconstruct high $p_T$ muons in proton--proton collisions are presented as well as the measurement of the environmental background rate to produce hits in the GEM detector.

physics.ins-det

Modeling the triple-GEM detector response to background particles for the CMS Experiment

An estimate of environmental background hit rate on triple-GEM chambers is performed using Monte Carlo (MC) simulation and compared to data taken by test chambers installed in the CMS experiment (GE1/1) during Run-2 at the Large Hadron Collider (LHC). The hit rate is measured using data collected with proton-proton collisions at 13 TeV and a luminosity of 1.5$\times10^{34}$ cm$^{-2}$ s$^{-1}$. The simulation framework uses a combination of the FLUKA and Geant4 packages to obtain the hit rate. FLUKA provides the radiation environment around the GE1/1 chambers, which is comprised of the particle flux with momentum direction and energy spectra ranging from $10^{-11}$ to $10^{4}$ MeV for neutrons, $10^{-3}$ to $10^{4}$ MeV for $γ$'s, $10^{-2}$ to $10^{4}$ MeV for $e^{\pm}$, and $10^{-1}$ to $10^{4}$ MeV for charged hadrons. Geant4 provides an estimate of detector response (sensitivity) based on an accurate description of detector geometry, material composition and interaction of particles with the various detector layers. The MC simulated hit rate is estimated as a function of the perpendicular distance from the beam line and agrees with data within the assigned uncertainties of 10-14.5%. This simulation framework can be used to obtain a reliable estimate of background rates expected at the High Luminosity LHC.

physics.ins-det

Interstrip Capacitances of the Readout Board used in Large Triple-GEM Detectors for the CMS Muon Upgrade

We present analytical calculations, Finite Element Analysis modeling, and physical measurements of the interstrip capacitances for different potential strip geometries and dimensions of the readout boards for the GE2/1 triple-Gas Electron Multiplier detector in the CMS muon system upgrade. The main goal of the study is to find configurations that minimize the interstrip capacitances and consequently maximize the signal-to-noise ratio for the detector. We find agreement at the 1.5--4.8% level between the two methods of calculations and on the average at the 17% level between calculations and measurements. A configuration with halved strip lengths and doubled strip widths results in a measured 27--29% reduction over the original configuration while leaving the total number of strips unchanged. We have now adopted this design modification for all eight module types of the GE2/1 detector and will produce the final detector with this new strip design.

physics.ins-det

u-RANIA: a neutron detector based on μ-RWELL technology

In the framework of the ATTRACT-uRANIA project, funded by the European Community, we are developing an innovative neutron imaging detector based on micro-Resistive WELL ($μ$ -RWELL) technology. The $μ$ -RWELL, based on the resistive detector concept, ensuring an efficient spark quenching mechanism, is a highly reliable device. It is composed by two main elements: a readout-PCB and a cathode. The amplification stage for this device is embedded in the readout board through a resistive layer realized by means of an industrial process with DLC (Diamond-Like Carbon). A thin layer of B$_4$C on the copper surface of the cathode allows the thermal neutrons detection through the release of $^7$Li and $α$ particles in the active volume. This technology has been developed to be an efficient and convenient alternative to the $^3$He shortage. The goal of the project is to prove the feasibility of such a novel neutron detector by developing and testing small planar prototypes with readout boards suitably segmented with strip or pad read out, equipped with existing electronics or readout in current mode. Preliminary results from the test with different prototypes, showing a good agreement with the simulation, will be presented together with construction details of the prototypes and the future steps of the project.

physics.ins-det

Study on the career trajectories of people with a working experience at CERN

This document describes the results of a study, aiming to measure the impact of CERN and of its environment on the career of people who worked at the laboratory. The data was collected using two on-line questionnaires, launched in 2016 and 2017, targeting experimentalists and theorists, respectively. The mandate, the methodology followed, the questionnaires and the analysis of the data collected are presented.

physics.ed-ph

A novel application of Fiber Bragg Grating (FBG) sensors in MPGD

We present a novel application of Fiber Bragg Grating (FBG) sensors in the construction and characterisation of Micro Pattern Gaseous Detector (MPGD), with particular attention to the realisation of the largest triple (Gas electron Multiplier) GEM chambers so far operated, the GE1/1 chambers of the CMS experiment at LHC. The GE1/1 CMS project consists of 144 GEM chambers of about 0.5 m2 active area each, employing three GEM foils per chamber, to be installed in the forward region of the CMS endcap during the long shutdown of LHC in 2108-2019. The large active area of each GE1/1 chamber consists of GEM foils that are mechanically stretched in order to secure their flatness and the consequent uniform performance of the GE1/1 chamber across its whole active surface. So far FBGs have been used in high energy physics mainly as high precision positioning and re-positioning sensors and as low cost, easy to mount, low space consuming temperature sensors. FBGs are also commonly used for very precise strain measurements in material studies. In this work we present a novel use of FBGs as flatness and mechanical tensioning sensors applied to the wide GEM foils of the GE1/1 chambers. A network of FBG sensors have been used to determine the optimal mechanical tension applied and to characterise the mechanical tension that should be applied to the foils. We discuss the results of the test done on a full-sized GE1/1 final prototype, the studies done to fully characterise the GEM material, how this information was used to define a standard assembly procedure and possible future developments.

physics.ins-det

Performance of a Large-Area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System

Gas Electron Multiplier (GEM) technology is being considered for the forward muon upgrade of the CMS experiment in Phase 2 of the CERN LHC. Its first implementation is planned for the GE1/1 system in the $1.5 < \midη\mid < 2.2$ region of the muon endcap mainly to control muon level-1 trigger rates after the second long LHC shutdown. A GE1/1 triple-GEM detector is read out by 3,072 radial strips with 455 $μ$rad pitch arranged in eight $η$-sectors. We assembled a full-size GE1/1 prototype of 1m length at Florida Tech and tested it in 20-120 GeV hadron beams at Fermilab using Ar/CO$_{2}$ 70:30 and the RD51 scalable readout system. Four small GEM detectors with 2-D readout and an average measured azimuthal resolution of 36 $μ$rad provided precise reference tracks. Construction of this largest GEM detector built to-date is described. Strip cluster parameters, detection efficiency, and spatial resolution are studied with position and high voltage scans. The plateau detection efficiency is [97.1 $\pm$ 0.2 (stat)]\%. The azimuthal resolution is found to be [123.5 $\pm$ 1.6 (stat)] $μ$rad when operating in the center of the efficiency plateau and using full pulse height information. The resolution can be slightly improved by $\sim$ 10 $μ$rad when correcting for the bias due to discrete readout strips. The CMS upgrade design calls for readout electronics with binary hit output. When strip clusters are formed correspondingly without charge-weighting and with fixed hit thresholds, a position resolution of [136.8 $\pm$ 2.5 stat] $μ$rad is measured, consistent with the expected resolution of strip-pitch/$\sqrt{12}$ = 131.3 $μ$rad. Other $η$-sectors of the detector show similar response and performance.

physics.ins-det

SuperB Technical Design Report

In this Technical Design Report (TDR) we describe the SuperB detector that was to be installed on the SuperB e+e- high luminosity collider. The SuperB asymmetric collider, which was to be constructed on the Tor Vergata campus near the INFN Frascati National Laboratory, was designed to operate both at the Upsilon(4S) center-of-mass energy with a luminosity of 10^{36} cm^{-2}s^{-1} and at the tau/charm production threshold with a luminosity of 10^{35} cm^{-2}s^{-1}. This high luminosity, producing a data sample about a factor 100 larger than present B Factories, would allow investigation of new physics effects in rare decays, CP Violation and Lepton Flavour Violation. This document details the detector design presented in the Conceptual Design Report (CDR) in 2007. The R&D and engineering studies performed to arrive at the full detector design are described, and an updated cost estimate is presented. A combination of a more realistic cost estimates and the unavailability of funds due of the global economic climate led to a formal cancelation of the project on Nov 27, 2012.

physics.ins-det

OPAL and More

We shall summarize some of the research activities performed in collaboration with Ben Shen in the OPAL experiment at LEP and in the CMS experiment at the LHC. And we shall recall the LEP legacy to particle physics in general and to the Standard Model in particular. Short recollections are made in other fields in which Ben was interested, in particular in Astroparticle Physics.

hep-ex