SearcharxivSearch

arXiv subjects

P. Moskal

Publications and source records attributed to P. Moskal.

At least 19 recordsLinked to original sources

High-precision measurement of the kaonic hydrogen 1s level shift and width with SIDDHARTA-2

Kaonic atoms provide a unique experimental probe of strong interaction in the low-energy regime. In particular, the strong-interaction-induced shift ($\varepsilon_{1\text{s}}$) and width ($\Gamma_{1\text{s}}$) of kaonic hydrogen directly constrain the low-energy antikaon-nucleon ($\bar{K}N$) interaction at threshold and the theoretical description of the $\Lambda$(1405) resonance. We report a new high-precision measurement of kaonic hydrogen X-ray transitions performed by the SIDDHARTA-2 experiment at the DA$\Phi$NE collider (INFN-LNF), based on an integrated luminosity of 237 pb$^{-1}$. The extracted values, $\varepsilon_{1\text{s}}\,=\,-303.0\,\pm\,17.0\,(stat.)\,\pm\,2.5\,(syst.)$ eV and $\Gamma_{1\text{s}}\,=\,607\,\pm\,62\,(stat.)\,\pm\,6\,(syst.)$ eV, represent the most precise determination to date, improving the precision by approximately a factor-of-two with respect to the previous SIDDHARTA measurement. These results significantly tighten the experimental constraints on theoretical description of the low-energy $\bar{K}N$ interaction.

nucl-ex

Bound-state QED test above the Schwinger limit with kaonic fluorine

Kaonic atoms, formed when a negatively charged kaon replaces an electron in an atomic orbit, provide access to bound-state quantum electrodynamics (BSQED) in electromagnetic fields far stronger than in ordinary atoms. Here, we report an experimental test of BSQED in a regime where the mean Coulomb field exceeds the Schwinger limit. Using high-precision x-ray spectroscopy of kaonic fluorine with the SIDDHARTA-2 experiment at DA$\Phi$NE, corresponding to an integrated luminosity of 22.4 pb$^{-1}$, we observe transitions involving the 4f and 3d levels, probing field-to-Schwinger-limit ratios of 1.11 and 3.70, respectively. The measured transition energies agree with state-of-the-art Dirac-Fock calculations. In particular, the 5g-4f transition showing a residual of 5.8 $\pm$ 4.7 (stat.) $\pm$ 5.5 (syst.) eV and a $\sim$ 9$\sigma$ sensitivity to QED contributions. These results provide a direct test of BSQED in the strong-field regime of QED above the Schwinger limit, opening a new avenue for precision studies in extreme electromagnetic fields.

physics.atom-ph

Three-Nucleon Dynamics in the dp breakup collisions at 190 MeV/nucleon using the WASA detector at COSY-J\"{u}lich

The differential cross section for the $^{1}$H$(d,pp)n$ breakup reaction at deuteron beam energy of 380 MeV has been determined with high precision for 189 angular configurations of outgoing protons in the region of forward laboratory angles. The cross section data were compared to theoretical predictions based on the state-of-the-art nucleon-nucleon potentials, combined with a three-nucleon force, the Coulomb interaction or carried out in a relativistic approach. In the region of the lowest differential cross section, the discrepancy between the data and the theoretical predictions is observed, also in the case of relativistic calculations.

nucl-ex

New 1mm thick Silicon Drift Detectors for future researches of Kaonic Atoms and the Pauli Exclusion principle

Kaonic atoms, formed when a negatively charged kaon replaces an electron, provide a sensitive probe of the low-energy strong interaction via precision X-ray spectroscopy. The SIDDHARTA-2 experiment at the DA$\Phi$NE collider employs high-performance Silicon Drift Detectors (SDDs) optimized for the 4-12 keV range to study light kaonic systems. In preparation for the EXKALIBUR phase, which targets heavier kaonic atoms, new 1 mm-thick SDDs have been developed with Politecnico di Milano and Fondazione Bruno Kessler. Their increased thickness enhances the quantum efficiency by a factor of about two at 30 keV while preserving excellent energy resolution. These detectors are also intended for VIP-3, the next-generation test of the Pauli Exclusion Principle (PEP). Building on VIP-2, which set the most stringent limits on PEP-violating $K_{\alpha}$ transitions in copper, VIP-3 will extend the search to heavier elements such as Ag, Sn, and Zr. Preliminary measurements demonstrate efficient detection up to 30 keV, supporting future high-precision studies of the kaon-nucleon interaction and PEP in heavier systems.

physics.ins-det

Studies of CPT symmetry in positronium decays with 192 plastic strip J-PET detector

A direct test of the CPT symmetry is performed for the electromagnetic decays of ortho-positronium using the J-PET tomograph. We present the precise measurement of the CPT-sensitive angular correlation entailing the positronium spin and the momenta of its annihilation photons, surpassing previous studies utilizing the same detection system. Positrons originating from a $^{22}$Na source are emitted from the detector's center and subsequently form positronium atoms within the spherical chamber covered with porous material. Reconstruction of annihilation locations using the 192-strip J-PET detector makes it possible to determine the positronium emission direction, which defines the quantization axis along which positronium is polarized, without the application of external magnetic fields. The measurements were performed in total for 356 days resulting in an identification of 47.8 million events with ortho-positronium decays into three photons. The results are consistent with the exactness of CPT symmetry with measured asymmetry amplitude -0.00029 $\pm$ 0.00022 (stat.) and with statistical error four times smaller than the previous best measurement.

nucl-ex

Spectrometry of Captured Highly Charged Ions Produced Following Antiproton Annihilations

We report a proof-of-principle study demonstrating the first capture and time-of-flight spectrometry of highly charged ions (HCIs) produced following antiproton annihilations in a Penning-Malmberg trap. A multi-step nested-trap technique was developed using the \aegis\ experiment to identify annihilation-linked captured ions. The trapping and spectrometry of helium and argon ions demonstrates the approach. This work establishes a foundation for the in-trap synthesis of radioactive HCIs and the study of cold nuclear annihilation fragments, with the long-term goal of enabling a sensitive tool for probing the outer nuclear periphery.

nucl-ex

Excitation Spectra of the ${}^{12}{\rm C}(p,d)$ Reaction near the $\eta'$-Meson Emission Threshold Measured in Coincidence with High-Momentum Protons

The missing mass of the ${}^{12}{\rm C}(p,d)$ reaction has been measured near the $\eta'$-meson emission threshold in coincidence with a high-momentum proton to selectively collect $\eta'$-${}^{11}{\rm C}$ mesic nucleus formation events at GSI, Germany. A 2.5 GeV proton excites a carbon nucleus to form an $\eta'$-mesic nucleus emitting a deuteron forward with an energy of $\sim 1.6$ GeV. The deuteron is momentum-analyzed by the Fragment Separator used as a high-resolution spectrometer to deduce the excitation energy of the residual system. The large-acceptance detector WASA surrounding the target identifies high-momentum protons emitted in the decay of the $\eta'$-mesic nucleus. The measured semi-exclusive spectrum exhibits structures below the threshold though the statistical significance is limited. The spectrum is fitted by theoretically calculated spectra varying optical-potential parameters of the $\eta'$-nucleus interaction. The analysis results indicate $\eta'$-mesic nuclei formation for the real potential depth of $\sim -61$ MeV with a local statistical significance of $3.5 \sigma$ and, taking into account the look-elsewhere effect, a global significance of $2.1 \sigma$.

nucl-ex

Precision Test of Bound-State QED at Intermediate-Z with Kaonic Neon

We report Dirac-Fock calculations of transition energies for kaonic neon (KNe). For the most intense line, the 7-6 transition, the calculated energy is 9450.28 eV, which includes a bound-state QED (BSQED) contribution of 12.66 eV. This is in excellent agreement with the recent SIDDHARTHA-2 measurement at DA$\Phi$NE of 9450.23 $\pm$ 0.37 (stat.) $\pm$ 1.50 (syst.) eV. With the QED shift far exceeding experimental uncertainty, these results establish kaonic atoms as powerful platforms for precision tests of BSQED in intermediate-Z systems.

physics.atom-ph

Performance of newly constructed plastic scintillator barrel in the WASA-FRS experiments and evaluation of radiation damage effects on multi-pixel photon counter

A barrel-shaped plastic scintillation counter with Multi-Pixel Photon Counter (MPPC) readout has been developed and operated in the first WASA-FRS experimental campaign at GSI. The detector was used to measure charged particles emitted from reactions induced by a 2.5 GeV proton beam incident on a carbon target, providing particle identification in combination with momentum reconstruction in a 1 T magnetic field. The performance of this detector, particularly its response to energy deposition and time resolution, was systematically investigated as a function of count rate and total number of irradiating protons. A time resolution of 45-75 ps ($\sigma$), depending on the energy deposition, was achieved. Stable performance was maintained under high-rate conditions up to 1.35 MHz per single counter, with no significant degradation in either signal amplitude or timing response. Radiation-induced damage to the MPPCs was observed primarily as a reduction in signal amplitude, with approximately $35\%$ decrease at an estimated 1 MeV neutron-equivalent fluence of $2.4 \times 10^{10}$ cm$^{-2}$.

physics.ins-det

AEgIS Experiment at CERN: Design and Commissioning of SARA (Scintillator Assemblies to Reveal Annihilations)

SARA is the system of plastic scintillators coupled with silicon photomultipliers that will take part in the AEgIS experiment at CERN, measuring the time-of-flight of antihydrogen as it falls through a moir\'e deflectometer. Its development focused on simplicity, versatility and economy of the design and was supported by both physical tests and finite elements numerical simulations. The instrument's structure pairs the utilization of the scintillators as structural components with custom made 3D printed corner elements and the electronics allows selection between coincidence discrimination made on each scintillator and made between different scintillators.

physics.ins-det

Measurement of $\eta\to\pi^{0}\gamma\gamma$ branching fraction with the KLOE detector

We present a measurement of the radiative decay $\eta\to\pi^0\gamma\gamma$ using 82 million $\eta$ mesons produced in $e^+e^-\to\phi\to\eta\gamma$ process at the Frascati $\phi$-factory DA$\Phi$NE. From the data analysis $1246\pm133$ signal events are observed. By normalising the signal to the well-known $\eta\to3\pi^0$ decay the branching fraction ${\cal B}(\eta\to\pi^0\gamma\gamma)$ is measured to be $(0.98\pm 0.11_\text{stat}\pm 0.14_\text{syst})\times10^{-4}$. This result agrees with a preliminary KLOE measurement, but is twice smaller than the present world average. Results for $d\Gamma(\eta\to\pi^0\gamma\gamma)/dM^2(\gamma\gamma)$ are also presented and compared with latest theory predictions.

hep-ex

Nanoporosity imaging by positronium lifetime tomography

Positron Annihilation Lifetime Spectroscopy (PALS) is a well-established non-destructive technique used for nanostructural characterization of porous materials. It is based on the annihilation of a positron and an electron. Mean positron lifetime in the material depends on the free voids size and molecular environment, allowing the study of porosity and structural transitions in the nanometer scale. We have developed a novel method enabling spatially resolved PALS, thus providing tomography of nanostructural characterization of an extended object. Correlating space (position) and structural (lifetime) information brings new insight in materials studies, especially in the characterization of the purity and pore distribution. For the first time, a porosity image using stationary positron sources for the simultaneous measurement of the porous polymers XAD4, silica aerogel powder IC3100, and polyvinyl toluene scintillator PVT by the J-PET tomograph is demonstrated

physics.app-ph

Investigation of Novel Preclinical Total Body PET Designed With J-PET Technology:A Simulation Study

The growing interest in human-grade total body positron emission tomography (PET) systems has also application in small animal research. Due to the existing limitations in human-based studies involving drug development and novel treatment monitoring, animal-based research became a necessary step for testing and protocol preparation. In this simulation-based study two unconventional, cost-effective small animal total body PET scanners (for mouse and rat studies) have been investigated in order to inspect their feasibility for preclinical research. They were designed with the novel technology explored by the Jagiellonian-PET (J-PET) Collaboration. Two main PET characteristics: sensitivity and spatial resolution were mainly inspected to evaluate their performance. Moreover, the impact of the scintillator dimension and time-of-flight on the latter parameter was examined in order to design the most efficient tomographs. The presented results show that for mouse TB J-PET the achievable system sensitivity is equal to 2.35% and volumetric spatial resolution to 9.46 +- 0.54 mm3, while for rat TB J-PET they are equal to 2.6% and 14.11 +- 0.80 mm3, respectively. Furthermore, it was shown that the designed tomographs are almost parallax-free systems, hence, they resolve the problem of the acceptance criterion tradeoff between enhancing spatial resolution and reducing sensitivity.

physics.med-ph

Comparative studies of plastic scintillator strips with high technical attenuation length for the total-body J-PET scanner

Plastic scintillator strips are considered as one of the promising solutions for the cost-effective construction of total-body positron emission tomography, (PET) system. The purpose of the performed measurements is to compare the transparency of long plastic scintillators with dimensions 6 mm x 24 mm x 1000 mm and with all surfaces polished. Six different types of commercial, general purpose, blue-emitting plastic scintillators with low attenuation of visible light were tested, namely: polyvinyl toluene-based BC-408, EJ-200, RP-408, and polystyrene-based Epic, SP32 and UPS-923A. For determination of the best type of plastic scintillator for totalbody Jagiellonian positron emission tomograph (TB-J-PET) construction, emission and transmission spectra, and technical attenuation length (TAL) of blue light-emitting by the scintillators were measured and compared. The TAL values were determined with the use of UV lamp as excitation source, and photodiode as light detector. Emission spectra of investigated scintillators have maxima in the range from 420 nm to 429 nm. The BC-408 and EJ-200 have the highest transmittance values of about 90% at the maximum emission wavelength measured through a 6 mm thick scintillator strip and the highest technical attenuation length reaching about 2000 mm, allowing assembly of long detection modules for time-of-flight (TOF) J-PET scanners. Influence of the 6 mm x 6 mm, 12 mm x 6 mm, 24 mm x 6 mm cross-sections of the 1000 mm long EJ-200 plastic scintillator on the TAL and signal intensity was measured. The highest TAL value was determined for samples with 24 mm x 6 mm cross-section.

physics.ins-det

Non-maximal entanglement of photons from positron-electron annihilation demonstrated using a novel plastic PET scanner

In state-of-the-art Positron Emission Tomography (PET), information about annihilation photon polarization is unavailable. Here, we present a PET scanner built from plastic scintillators, where annihilation photons primarily interact via the Compton effect, providing information about both photon polarization and propagation direction. Using this plastic-based PET, we determined the distribution of the relative angle between polarization planes of photons from positron-electron annihilation in a porous polymer. The amplitude of the observed distribution is smaller than predicted for maximally quantum-entangled two-photon states but larger than expected for separable photons. This result can be well explained by assuming that photons from pick-off annihilation are not entangled, while photons from direct and para-positronium annihilations are maximally entangled. Our result indicates that the degree of entanglement depends on the annihilation mechanism in matter, opening new avenues for exploring polarization correlations in PET as a diagnostic indicator.

nucl-ex

Real-time antiproton annihilation vertexing with sub-micron resolution

The primary goal of the AEgIS experiment is to precisely measure the free fall of antihydrogen within Earth's gravitational field. To this end, a cold ~50K antihydrogen beam has to pass through two grids forming a moir\'e deflectometer before annihilating onto a position-sensitive detector, which shall determine the vertical position of the annihilation vertex relative to the grids with micrometric accuracy. Here we introduce a vertexing detector based on a modified mobile camera sensor and experimentally demonstrate that it can measure the position of antiproton annihilations with an accuracy of $0.62^{+0.40}_{-0.22}\mu m$, which represents a 35-fold improvement over the previous state-of-the-art for real-time antiproton vertexing. Importantly, these antiproton detection methods are directly applicable to antihydrogen. Moreover, the sensitivity to light of the sensor enables the in-situ calibration of the moir\'e deflectometer, significantly reducing systematic errors. This sensor emerges as a breakthrough technology for achieving the \aegis scientific goals and has been selected as the basis for the development of a large-area detector for conducting antihydrogen gravity measurements.

physics.ins-det

Kaonic lead feasibility measurement at DA{\Phi}NE to solve the charged kaon mass discrepancy

An HPGe detector equipped with a transistor reset preamplifier and readout with a CAEN DT5781 fast pulse digitizer was employed in the measurement of X-rays from kaonic lead at the DA$\Phi$NE $e^+e^-$ collider at the Laboratori Nazionali di Frascati of INFN. A thin scintillator in front of a lead target was used to select kaons impinging on it and to form the trigger for the HPGe detector. We present the results of the kaonic lead feasibility measurement, where we show that the resolution of the HPGe detector in regular beam conditions remains the same as that without the beam and that a satisfactory background reduction can be achieved. This measurement serves as a test bed for future dedicated kaonic X-rays measurements for the more precise determination of the charged kaon mass.

physics.ins-det

SIDDHARTA-2 apparatus for kaonic atoms research on the DA$\Phi$NE collider

SIDDHARTA-2 represents a state-of-the-art experiment designed to perform dedicated measurements of kaonic atoms, which are particular exotic atom configurations composed of a negatively charged kaon and a nucleus. Investigating these atoms provides an exceptional tool to comprehend the strong interactions in the non-perturbative regime involving strangeness. The experiment is installed at the DA$\Phi$NE electron-positron collider, of the INFN National Laboratory of Frascati (INFN-LNF) in Italy, aiming to perform the first-ever measurement of the 2p$\rightarrow$1s X-ray transitions in kaonic deuterium, a crucial step towards determining the isospin-dependent antikaon-nucleon scattering lengths. Based on the experience gained with the previous SIDDHARTA experiment, which performed the most precise measurement of the kaonic hydrogen 2p$\rightarrow$1s X-ray transitions, the present apparatus has been upgraded with innovative Silicon Drift Detectors (SDDs), distributed around a cryogenic gaseous target placed in a vacuum chamber at a short distance above the interaction region of the collider. We present a comprehensive description of the SIDDHARTA-2 setup including the optimization of its various components during the commissioning phase of the collider.

physics.ins-det