SearcharxivSearch

arXiv subjects

P. Parygin

Publications and source records attributed to P. Parygin.

3 recordsLinked to original sources

Characterization of afterpulse in SiPMs with single-cell readout as a function of bias voltage and fluence

We present a detailed investigation of the afterpulse effect in silicon photomultipliers (SiPMs), using a dedicated structure with single-cell readout. This enables direct measurement of intrinsic device properties and observation of individual pulses even after irradiation. Three independent analysis methods to quantify afterpulse induced events were developed and validated by Monte Carlo simulations. The first method is based on charge integration, while the other two methods use multiple linear regression to reconstruct transient waveforms and accurately identify individual pulse positions. These positions are then used either as direct event counts or to construct time interval distributions, enabling comprehensive characterization of the afterpulse probability and providing insights into the dynamics of trapping in silicon. Using this framework, we measured three SiPM samples: one fresh reference device and two irradiated devices exposed to reactor neutron fluences of 2e12 and 1e13 cm^-2. We report systematic measurements of the afterpulse probability and time constant as functions of bias voltage and irradiation fluence. For overvoltages in the range of 3 to 5 V above breakdown, the afterpulse time constant is found to be below 10 ns and the afterpulse probability below 6%. Both quantities show no significant dependence on irradiation fluence.

physics.ins-det

Radiation damage uniformity in a SiPM

A dedicated single-cell SiPM structure is designed and measured to investigate the radiation damage effects on the gain and breakdown voltage of SiPMs exposed to a reactor neutron fluence up to $\Phi$ = 5e13 cm$^{-2}$. The cell has a pitch of 15 $\mu$m. Results of the measurements and analysis of the IV-curves are presented. Impact of the self-heating effect was investigated. The radiation damage uniformity of 1 cell and 120 cells was checked up to $U_\mathit{ov}$ = 1.7 V. Fluence dependence of the breakdown voltage from the current measurements $U^{IV}_\mathit{bd}$ was extracted and compared to that of the breakdown voltage from the gain measurements $U^{G}_\mathit{bd}$.

physics.ins-det

Radiation hardness study using SiPMs with single-cell readout

A dedicated single-cell SiPM structure is designed and measured to investigate the radiation damage effects on the gain and turn-off voltage of SiPMs exposed to a reactor neutron fluence up to $\Phi$ = 5e13 cm$^{-2}$. The cell has a pitch of 15 $\mu$m. The fluence dependence of gain and turn-off voltage are reported. A reduction of the gain by 19% and an increase of $V_{off}$ by $\approx$0.5 V is observed after $\Phi$ = 5e13 cm$^{-2}$.

physics.ins-det