SearcharxivSearch

arXiv subjects

P. Smolyanskiy

Publications and source records attributed to P. Smolyanskiy.

13 recordsLinked to original sources

Introducing Timepix2-Lite: A Miniaturized Readout Interface Enabling Nanosecond-Scale Half-Life Measurement

This paper presents Timepix2 Lite, a compact readout interface for the Timepix2 hybrid pixel detector, designed to provide high spatial and temporal resolution in a wide range of radiation detection applications. The Timepix2 Lite enables simultaneous energy and precise timing measurements on the nanosecond scale and supports advanced real-time data acquisition and visualization through the TrackLab software framework. Its compact and flexible architecture, enabled by the miniaturized design, allows seamless integration into diverse experimental setups, including nuclear spectroscopy, stratospheric balloon missions, and nanosecond-scale half-life measurements. As a case study, the half-life of the second excited state in 237Np was determined to be 67.5(7) ns for the 59.5 keV transition, consistent with previously reported results.

physics.ins-det

Experimental evidence of production of directional muons from a laser-wakefield accelerator

We report on experimental evidence of the generation of directional muons from a laser-wakefield accelerator driven by a PW-class laser. The muons were generated following the interaction of a GeV-scale high-charge electron beam with a 2cm-thick Pb target and were detected using a Timepix3 detector placed behind a suitable shielding configuration. Data analysis indicates a $(99.1\pm0.5)$% confidence of muon detection over noise, in excellent agreement with numerical modelling. Extrapolation of the experimental setup to higher electron energies and charges suggests the potential to guide and separate from noise approximately $10^4$ muons/s onto cm$^2$-scale areas for applications using a 10 Hz PW laser. These results demonstrate the possibility of generating and transporting directional muon beams using high-power lasers and establish a foundation for the systematic application of laser-driven high-energy muon beams.

physics.acc-ph

TALOS (Total Automation of LabVIEW Operations for Science): A framework for autonomous control systems for complex experiments

Modern physics experiments are frequently very complex, relying on multiple simultaneous events to happen in order to obtain the desired result. The experiment control system plays a central role in orchestrating the measurement setup: However, its development is often treated as secondary with respect to the hardware, its importance becoming evident only during the operational phase. Therefore, the AEgIS (Antimatter Experiment: Gravity, Interferometry, Spectroscopy) collaboration has created a framework for easily coding control systems, specifically targeting atomic, quantum, and antimatter experiments. This framework, called Total Automation of LabVIEW Operations for Science (TALOS), unifies all the machines of the experiment in a single entity, thus enabling complex high-level decisions to be taken, and it is constituted by separate modules, called MicroServices, that run concurrently and asynchronously. This enhances the stability and reproducibility of the system while allowing for continuous integration and testing while the control system is running. The system demonstrated high stability and reproducibility, running completely unsupervised during the night and weekends of the data-taking campaigns. The results demonstrate the suitability of TALOS to manage an entire physics experiment in full autonomy: being open-source, experiments other than the AEgIS experiment can benefit from it.

physics.ins-det

Real-time antiproton annihilation vertexing with sub-micron resolution

The primary goal of the AEgIS experiment is to precisely measure the free fall of antihydrogen within Earth's gravitational field. To this end, a cold ~50K antihydrogen beam has to pass through two grids forming a moir\'e deflectometer before annihilating onto a position-sensitive detector, which shall determine the vertical position of the annihilation vertex relative to the grids with micrometric accuracy. Here we introduce a vertexing detector based on a modified mobile camera sensor and experimentally demonstrate that it can measure the position of antiproton annihilations with an accuracy of $0.62^{+0.40}_{-0.22}\mu m$, which represents a 35-fold improvement over the previous state-of-the-art for real-time antiproton vertexing. Importantly, these antiproton detection methods are directly applicable to antihydrogen. Moreover, the sensitivity to light of the sensor enables the in-situ calibration of the moir\'e deflectometer, significantly reducing systematic errors. This sensor emerges as a breakthrough technology for achieving the \aegis scientific goals and has been selected as the basis for the development of a large-area detector for conducting antihydrogen gravity measurements.

physics.ins-det

Positronium laser cooling via the $1^3S$-$2^3P$ transition with a broadband laser pulse

We report on laser cooling of a large fraction of positronium (Ps) in free-flight by strongly saturating the $1^3S$-$2^3P$ transition with a broadband, long-pulsed 243 nm alexandrite laser. The ground state Ps cloud is produced in a magnetic and electric field-free environment. We observe two different laser-induced effects. The first effect is an increase in the number of atoms in the ground state after the time Ps has spent in the long-lived $3^3P$ states. The second effect is the one-dimensional Doppler cooling of Ps, reducing the cloud's temperature from 380(20) K to 170(20) K. We demonstrate a 58(9) % increase in the coldest fraction of the Ps ensemble.

physics.atom-ph

Radiation hardness of GaAs: Cr and Si sensors irradiated by electron beam

The interest in using the radiation detectors based on high resistive chromium-compensated GaAs (GaAs:Cr) in high energy physics and others applied fields has been growing steadily due to its numerous advantages over others classical materials. High radiation hardness at room temperature stands out and needs to be systematically investigated. In this paper an experimental study of the effect of 20.9 MeV electrons generated by the LINAC-200 accelerator on some properties of GaAs:Cr based sensors is presented. In parallel, Si sensors were irradiated at the same conditions, measured and analyzed in order to perform a comparative study. The target sensors were irradiated with the dose up to 1.5 MGy. The current-voltage characteristics, resistivity, charge collection efficiency and their dependences on the bias voltage and temperature were measured at different absorbed doses. An analysis of the possible microscopic mechanisms leading to the observed effects in GaAs:Cr sensors is presented in the article.

physics.ins-det

Visualization of radiotracers for SPECT imaging using a Timepix detector with a coded aperture

The work shows the ability to visualize radiotracers used in SPECT with a system based on a coded aperture mask and a hybrid pixel Timepix detector with the CdTe sensor. Characterization of the system using X-rays and radioactive sources confirms that the spatial resolution of less than 1 mm with a field of view 3 cm x 3 cm can be achieved. The results of a simulation study to determine the expected spatial resolution of the system in the focal plane for the various radionuclides is presented. The possibility of using this system with a thin (1.5 mm) coded aperture mask for reconstructing images of gamma emitters with the energy up to 180 keV is demonstrated.

physics.med-ph

Measurement of shower development and its Molière radius with a four-plane LumiCal test set-up

A prototype of a luminometer, designed for a future e+e- collider detector, and consisting at present of a four-plane module, was tested in the CERN PS accelerator T9 beam. The objective of this beam test was to demonstrate a multi-plane tungsten/silicon operation, to study the development of the electromagnetic shower and to compare it with MC simulations. The Molière radius has been determined to be 24.0 +/- 0.6 (stat.) +/- 1.5 (syst.) mm using a parametrization of the shower shape. Very good agreement was found between data and a detailed Geant4 simulation.

physics.ins-det

Properties of GaAs:Cr-based Timepix detectors

It is the hybrid pixel detector technology which brought to the X-ray imaging a low noise level at a high spatial resolution, thanks to the single photon counting. However, silicon as the most widespread detector material is marginally sensitive to photons with energy more than 30 keV. That's why the high-Z alternatives to silicon such as gallium arsenide and cadmium telluride are increasingly attracting attention of the community for the development of X-ray imaging systems in recent years. We present in this work the results of our investigations of the Timepix detectors bump-bonded with sensors made of gallium arsenide compensated by chromium (GaAs:Cr). The properties which are mostly important from the practical point of view: IV characteristics, charge transport characteristics, operational stability, homogeneity, temperature dependence as well as energy and spatial resolution are considered. Applicability of these detectors for spectroscopic X-ray imaging is discussed.

physics.ins-det

Response of Timepix detector with GaAs:Cr and Si sensor to heavy ions

The response of the Timepix detector to neon ions with kinetic energy 77 and 158.4 MeV has been studied at the cyclotron U-400M of the JINR Flerov Laboratory of Nuclear Reaction. Sensors produced from gallium arsenide compensated by chromium and from silicon are used for these measurements. While in Timepix detector with Si sensor the well-known so-called "volcano effect" observed, in Timepix detector with GaAs:Cr sensor such effect was completely absent. In the work the behavior of the Timepix detector with GaAs:Cr sensor under irradiation with heavy ions is described in comparison with the detector based on Si sensor. Also the possible reason for absence of "volcano" effect in GaAs:Cr detector is proposed.

physics.ins-det

On the possibility to use semiconductive hybrid pixel detectors for study of radiation belt of the Earth

The scientific apparatus "Gamma-400" designed for study of hadron and electromagnetic components of cosmic rays will be launched to an elliptic orbit with the apogee of about 300 000 km and the perigee of about 500 km. Such a configuration of the orbit allows it to cross periodically the radiation belt and the outer part of magnetosphere. We discuss the possibility to use hybrid pixel detecters based on the Timepix chip and semiconductive sensors on board the "Gamma-400" apparatus. Due to high granularity of the sensor (pixel size is 55 $mu$m) and possibility to measure independently an energy deposition in each pixel, such compact and lightweight detector could be a unique instrument for study of spatial, energy and time structure of electron and proton components of the radiation belt.

astro-ph.IM

Performance of fully instrumented detector planes of the forward calorimeter of a Linear Collider detector

Detector-plane prototypes of the very forward calorimetry of a future detector at an e+e- collider have been built and their performance was measured in an electron beam. The detector plane comprises silicon or GaAs pad sensors, dedicated front-end and ADC ASICs, and an FPGA for data concentration. Measurements of the signal-to-noise ratio and the response as a function of the position of the sensor are presented. A deconvolution method is successfully applied, and a comparison of the measured shower shape as a function of the absorber depth with a Monte-Carlo simulation is given.

physics.ins-det

Alignment and resolution studies of a MARS scanner

The MARS scanner is designed for the x-ray spectroscopic study of samples with the aid of computer tomography methods. Computer tomography allows the reconstruction of slices of an investigated sample using a set of shadow projections obtained for different angles. Projections in the MARS scanner are produced using a cone x-ray beam geometry. Correct reconstruction in this scheme requires precise knowledge of several geometrical parameters of a tomograph, such as displacement of a rotation axis, x-ray source position with respect to a camera, and camera inclinations. Use of inaccurate parameters leads to a poor sample reconstruction. Non-ideal positioning of camera, x-ray source and cylindrical rotating frame (gantry) itself on which these parts are located, leads to the need for tomograph alignment. In this note we describe the alignment procedure that was used to get different geometrical corrections for the reconstruction. Also, several different estimations of the final spatial resolution for reconstructed images are presented.

physics.ins-det