Searcharxiv⌕ Search

arXiv subjects

Paul F. Griffin

Publications and source records attributed to Paul F. Griffin.

At least 19 recordsLinked to original sources

Field validation of GNSS-independent positioning enhancement using a wearable ultra-stable quantum magnetometer

Increasing the resilience of positioning systems that currently rely on Global Navigation Satellite System (GNSS) signals can be achieved by incorporating stable and sensitive measurements of the permanent crustal anomalies in the Earth's magnetic field. We have realised this concept using an in-house-developed, wearable, Free-Induction-Decay Optically Pumped Magnetometer (FID-OPM) to carry out precise and stable measurements of the geomagnetic field in a walking trial. We present an end-to-end validation, including qualification of FID-OPM performance, alongside quantification of improvement in accuracy when data from this sensor is added to a dead-reckoning estimation of position. Using our wearable sensor system we achieve a Beckmann-distributed radial positioning error of 2.24 m over a route exceeding 500 m in length and spanning approximately 360 s.

physics.atom-ph↗

High-Resolution Atomic Magnetometer-Based Imaging of Integrated Circuits and Batteries

Optically pumped magnetometers (OPMs) have emerged as a powerful technique for high-resolution magnetic field imaging. However, achieving sub-millimeter spatial resolution at sub-picotesla sensitivities ($\mathrm{< 1\,pT/\sqrt{Hz}}$) remains challenging, particularly under finite-field conditions. We present a high-resolution magnetic imaging system based on a free-induction-decay (FID) OPM integrated with a two-axis scanning micromirror for automated beam steering. The double-pass optical configuration allows millimeter-scale devices under test (DUTs) to be positioned directly behind the vapor cell. This enables a standoff distance of 2.7 mm between the magnetic source and the atomic vapor, improving practical imaging resolution by increasing the amplitude of near-field magnetic signals sampled within the sensitive volume. Spatial resolution is experimentally demonstrated by imaging a custom printed circuit board (PCB) containing antiparallel copper tracks spaced 2 mm apart, with measured field maps in close agreement with Biot-Savart predictions. The OPM achieves an optimal field sensitivity of $\mathrm{0.5\,pT/\sqrt{Hz}}$, demonstrating the system's capability for high-precision magnetic field measurements. The imaging system is further validated by resolving polarity-dependent asymmetries in a bridge rectifier integrated circuit (IC) and tracking current dynamics in a ceramic battery in situ. These results highlight the potential of OPM-based systems for noninvasive diagnostics of electronic circuits and batteries.

physics.atom-ph↗

Rapid axial loading of a grating MOT with a cold-atom beam

Laser-cooled atoms are increasingly being used to realise practical quantum devices, motivating the development of compact and robust atom sources. Grating magneto-optical traps (gMOTs) simplify the cold-atom source architecture but are typically vapour-loaded and provide limited atomic flux. Here we explore the loading of gMOTs from cold-atom beams. We numerically simulate loading to show that unbalanced diffracted beams deflect incoming atoms away from the trap centre, thereby strongly constraining radial loading. In contrast, axial loading injects atoms directly into the trapping volume and largely avoids these effects. We experimentally demonstrate rapid axial loading of a gMOT, achieving loading rates of $2.1 \times 10^9$ atoms~s$^{-1}$ using a moving optical molasses to transfer atoms from a 2D MOT into the gMOT. These results establish axial loading as a robust route to high-flux gMOT operation for portable cold-atom systems.

physics.atom-ph↗

Intrinsic atomic calibration of oscillating magnetic fields in ULF and VLF bands

We present a method for absolute calibration of received radio-frequency in the ultra low frequency (ULF), and very low frequency (VLF) range. This is achieved with the use of a radio frequency optically pumped magnetometer (RF-OPM). We describe a method using an optically pumped sample where the RF broadening of the Cs magnetic resonance allows the magnitude of the received field to be calibrated against the ground-state gyromagnetic ratio of the Cs atoms. This frequency-based calibration avoids the geometric and electrostatic response functions that affect inductive sensors, such as fluxgates, search coils, and SQUID magnetometers. We demonstrate calibration of magnetic measurement using oscillating magnetic fields in the 300 Hz - 20 kHz range and a sensor noise floor of 15 fT.Hz-1/2. This radio-frequency sensor may be used as a widely tunable narrowband receiver for communication, ranging, or penetrative conductivity imaging.

physics.atom-ph↗

Single-beam grating-chip 3D and 1D optical lattices

Ultracold atoms are crucial for unlocking truly precise and accurate quantum metrology, and provide an essential platform for quantum computing, communication and memories. One of the largest ongoing challenges is the miniaturization of these quantum devices. Here, we show that the typically macroscopic optical lattice architecture at the heart of many ultra-precise quantum technologies can be realized with a single input laser beam on the same diffractive chip already used to create the ultracold atoms. Moreover, this inherently ultra-stable platform enables access to a plethora of new lattice dimensionalities and geometries, ideally suited for the design of high-accuracy, portable quantum devices.

cond-mat.quant-gas↗

Optimal binary gratings for multi-wavelength magneto-optical traps

Grating magneto-optical traps are an enabling quantum technology for portable metrological devices with ultracold atoms. However, beam diffraction efficiency and angle are affected by wavelength, creating a single-optic design challenge for laser cooling in two stages at two distinct wavelengths - as commonly used for loading e.g. Sr or Yb atoms into optical lattice or tweezer clocks. Here, we optically characterize a wide variety of binary gratings at different wavelengths to find a simple empirical fit to experimental grating diffraction efficiency data in terms of dimensionless etch depth and period for various duty cycles. The model avoids complex 3D light-grating surface calculations, yet still yields results accurate to a few percent across a broad range of parameters. Gratings optimized for two (or more) wavelengths can now be designed in an informed manner suitable for a wide class of atomic species enabling advanced quantum technologies.

physics.atom-ph↗

Optical pumping enhancement of a free-induction-decay magnetometer

Spin preparation prior to a free-induction-decay (FID) measurement can be adversely affected by transverse bias fields, particularly in the geophysical field range. A strategy that enhances the spin polarization accumulated before readout is demonstrated, by synchronizing optical pumping with a magnetic field pulse that supersedes any transverse fields by over two order of magnitude. The pulsed magnetic field is generated along the optical pumping axis using a compact electromagnetic coil pair encompassing a micro-electromechanical systems (MEMS) vapor cell. The coils also resistively heat the cesium (Cs) vapor to the optimal atomic density without spurious magnetic field contributions as they are rapidly demagnetized to approximately zero field during spin readout. The demagnetization process is analyzed electronically, and directly with a FID measurement, to confirm that the residual magnetic field is minimal during detection. The sensitivity performance of this technique is compared to existing optical pumping modalities across a wide magnetic field range. A noise floor sensitivity of $238\,\mathrm{fT/\surd{Hz}}$ was achieved in a field of approximately $\mathrm{50\,μ{T}}$, in close agreement with the Cramér-Rao lower bound (CRLB) predicted noise density of $258\,\mathrm{fT/\surd{Hz}}$.

physics.atom-ph↗

A grating-chip atomic fountain

Cold atom fountain clocks provide exceptional long term stability as they increase interrogation time at the expense of a larger size. We present a compact cold atom fountain using a grating magneto-optical trap (GMOT) to laser cool and launch the atoms in a simplified optical setup. The fountain is evaluated using coherent population trapping and demonstrates improved single-shot stability from the launch. Ramsey times up to 100 ms were measured with a corresponding fringe linewidth of 5 Hz. This technique could improve both short- and long-term stability of cold atom clocks whilst remaining compact for portable applications.

physics.atom-ph↗

Cold Atoms in Space: Community Workshop Summary and Proposed Road-Map

We summarize the discussions at a virtual Community Workshop on Cold Atoms in Space concerning the status of cold atom technologies, the prospective scientific and societal opportunities offered by their deployment in space, and the developments needed before cold atoms could be operated in space. The cold atom technologies discussed include atomic clocks, quantum gravimeters and accelerometers, and atom interferometers. Prospective applications include metrology, geodesy and measurement of terrestrial mass change due to, e.g., climate change, and fundamental science experiments such as tests of the equivalence principle, searches for dark matter, measurements of gravitational waves and tests of quantum mechanics. We review the current status of cold atom technologies and outline the requirements for their space qualification, including the development paths and the corresponding technical milestones, and identifying possible pathfinder missions to pave the way for missions to exploit the full potential of cold atoms in space. Finally, we present a first draft of a possible road-map for achieving these goals, that we propose for discussion by the interested cold atom, Earth Observation, fundamental physics and other prospective scientific user communities, together with ESA and national space and research funding agencies.

astro-ph.IM↗

Stand-alone vacuum cell for compact ultracold quantum technologies

Compact vacuum systems are key enabling components for cold atom technologies, facilitating extremely accurate sensing applications. There has been important progress towards a truly portable compact vacuum system, however size, weight and power consumption can be prohibitively large, optical access may be limited, and active pumping is often required. Here, we present a centilitre-scale ceramic vacuum chamber with He-impermeable viewports and an integrated diffractive optic, enabling robust laser cooling with light from a single polarization-maintaining fibre. A cold atom demonstrator based on the vacuum cell delivers $10^7$ laser-cooled $^{87}$Rb atoms per second, using minimal electrical power. With continuous Rb gas emission active pumping yields a $10^{-7}\,$mbar equilibrium pressure, and passive pumping stabilises to $3\times 10^{-6}\,$mbar, with a $17\,$day time constant. A vacuum cell, with no Rb dispensing and only passive pumping, has currently kept a similar pressure for more than \ch{500 days}. The passive-pumping vacuum lifetime is several years, estimated from short-term He throughput, with many foreseeable improvements. This technology enables wide-ranging mobilization of ultracold quantum metrology.

physics.atom-ph↗

Compressive Sampling Using a Pushframe Camera

The recently described pushframe imager, a parallelized single pixel camera capturing with a pushbroom-like motion, is intrinsically suited to both remote-sensing and compressive sampling. It optically applies a 2D mask to the imaged scene, before performing light integration along a single spatial axis, but previous work has not made use of the architecture's potential for taking measurements sparsely. In this paper we develop a strongly performing static binarized noiselet compressive sampling mask design, tailored to pushframe hardware, allowing both a single exposure per motion time-step, and retention of 2D correlations in the scene. Results from simulated and real-world captures are presented, with performance shown to be similar to that of immobile -- and hence inappropriate for satellite use -- whole-scene imagers. A particular feature of our sampling approach is that the degree of compression can be varied without altering the pattern, and we demonstrate the utility of this for efficiently storing and transmitting multi-spectral images.

eess.IV↗

Gouy phase-matched angular and radial mode conversion in four-wave mixing

Studying the conversion between transverse light modes via four-wave mixing in a heated rubidium vapour, we demonstrate and explain a transfer between azimuthal and radial mode numbers. These relate to orthogonal modal dimensions, which one would not normally expect to interact. While angular momentum conservation in this nonlinear process dictates the selection rules for the angular mode number, the role of the radial mode number is more esoteric. We demonstrate systematically that the Gouy phase is the key to understanding this conversion, leading to strikingly different conversion behaviour in the thick and thin medium regime. Our experimental investigation of the transition between these regimes bridges the gap between previous experiments in atomic thick media and work in nonlinear crystals. Our work sets a clear starting point to explore new territory in the thick medium regime, allowing efficient radial-to-azimuthal and radial-to-radial mode conversion.

physics.atom-ph↗

Compact Multi-Spectral Pushframe Camera for Nano-Satellites

In this paper we present an evolution of the single-pixel camera architecture, called 'pushframe', which addresses the limitations of pushbroom cameras in space-based applications. In particular, it is well-suited to observing fast moving scenes while retaining high spatial resolution and sensitivity. We show that the system is capable of producing colour images with good fidelity and scalable resolution performance. The principle of our design places no restriction on the spectral range to be captured, making it suitable for wide infrared imaging.

eess.IV↗

Resonant Very Low- and Ultra Low Frequency Digital Signal Reception Using a Portable Atomic Magnetometer

Radio communication through attenuating media necessitates the use of very-low frequency (VLF) and ultra-low frequency (ULF) carrier bands, which are frequently used in underwater and under-ground communication applications. Quantum sensing techniques can be used to circumvent hard constraints on the size, weight and noise floor of classical signal transducers. In this low-frequency range, an optically pumped atomic sample can be used to detect carrier wave modulation resonant with ground-state Zeeman splitting of alkali atoms. Using a compact, self-calibrating system we demonstrate a resonant atomic transducer for digital data encoded using binary phase- and frequency-keying of resonant carrier waves in the 200 Hz -200 kHz range. We present field trial data showing sensor noise floor, decoded data and received bit error rate, and calculate the projected range of sub-sea communication using this device.

physics.atom-ph↗

Optical characterisation of micro-fabricated Fresnel zone plates for atomic waveguides

We optically assess Fresnel zone plates (FZPs) that are designed to guide cold atoms. Imaging of various ring patterns produced by the FZPs gives an average RMS error in the brightest part of the ring of 3% with respect to trap depth. This residue will be due to the imaging system, incident beam shape and FZP manufacturing tolerances. Axial propagation of the potentials is presented experimentally and through numerical simulations, illustrating prospects for atom guiding without requiring light sheets.

physics.atom-ph↗

Cold-atom clock based on a diffractive optic

Clocks based on cold atoms offer unbeatable accuracy and long-term stability, but their use in portable quantum technologies is hampered by a large physical footprint. Here, we use the compact optical layout of a grating magneto-optical trap (gMOT) for a precise frequency reference. The gMOT collects $10^7$ $^{87}$Rb atoms, which are subsequently cooled to $20\,μ$K in optical molasses. We optically probe the microwave atomic ground-state splitting using lin$\perp$lin polarised coherent population trapping and a Raman-Ramsey sequence. With ballistic drop distances of only $0.5\,$mm, the measured short-term fractional frequency stability is $2 \times 10 ^{-11} /\sqrtτ$.

physics.atom-ph↗

Vector Magnetometry Exploiting Phase-Geometry Effects in a Double-Resonance Alignment Magnetometer

Double-resonance optically pumped magnetometers are an attractive instrument for unshielded magnetic field measurements due to their wide dynamic range and high sensitivity. Use of linearly polarised pump light creates alignment in the atomic sample, which evolves in the local static magnetic field, and is driven by a resonant applied field perturbation, modulating the polarisation of transmitted light. We show for the first time that the amplitude and phase of observed first- and second-harmonic components in the transmitted polarisation signal contain sufficient information to measure static magnetic field magnitude and orientation. We describe a laboratory system for experimental measurements of these effects and verify a theoretical derivation of the observed signal. We demonstrate vector field tracking under varying static field orientations and show that the static field magnitude and orientation may be observed simultaneously, with experimentally realised resolution of 1.7 pT and 0.63 mrad in the most sensitive field orientation.

physics.atom-ph↗

Detection of Applied and Ambient Forces with a Matterwave Magnetic-Gradiometer

An atom interferometer using a Bose-Einstein condensate of $^{87}$Rb atoms is utilized for the measurement of magnetic field gradients. Composite optical pulses are used to construct a spatially symmetric Mach-Zehnder geometry. Using a biased interferometer we demonstrate the ability to measure small residual forces in our system at the position of the atoms. These are a residual magnetic field gradient of 15$\pm$2 mG/cm and and an inertial acceleration of 0.08$\pm$0.02 m/s$^2$. Our method has important applications in the calibration of precision measurement devices and the reduction of systematic errors.

physics.atom-ph↗