SearcharxivSearch

arXiv subjects

Pierre-Jean Nacher

Publications and source records attributed to Pierre-Jean Nacher.

10 recordsLinked to original sources

Generating accurate tip angles for NMR outside the rotating-wave approximation

The generation of accurate tip angles is critical for many applications of nuclear magnetic resonance. In low static field, with a linear rather than circular polarized rf field, the rotating-wave approximation may no longer hold and significant deviations from expected trajectories on the Bloch sphere can occur. For rectangular rf pulses, the effects depend strongly on the phase of the rf field and can be further compounded by transients at the start and end of the pulse. The desired terminus can be still be achieved, however, through the application of a phase-dependent Bloch-Siegert shift and appropriate consideration of pulse timings. For suitably shaped rf pulses, the Bloch-Siegert shift is largely phase independent, but its magnitude can vary significantly depending on details of the pulse shape as well as the characteristics of the rf coil circuit. We present numerical simulations and low-field NMR experiments with 1H and 3He that demonstrate several main consequences and accompanying strategies that one should consider when wanting to generate accurate tip angles outside the validity of the rotating-wave approximation and in low static field.

physics.med-ph

Nonlinear NMR dynamics in hyperpolarized liquid 3He

In a highly polarized liquid (laser-polarized 3He-4He mixtures in our experiment), dipolar magnetic interactions within the liquid introduce a significant nonlinear and nonlocal contribution to the Bloch equation that leads to instabilities during NMR evolution. We have launched a study of these instabilities using spin echo techniques. At high magnetizations, a simple 180 degree rf pulse fails to refocus magnetization, so we use a standard solid-state NMR pulse sequence: the magic sandwich. We report an experimental and numerical investigation of the effect of this sequence on unstable NMR evolution. Using a series of repeated magic sandwich sequences, the transverse magnetization lifetime can be increased by up to three orders of magnitude.

cond-mat.other

NMR Time Reversal Experiments in Highly Polarised Liquid 3He-4He Mixtures

Long-range magnetic interactions in highly magnetised liquids (laser-polarised 3He-4He dilute mixtures at 1 K in our experiment) introduce a significant non-linear and non-local contribution to the evolution of nuclear magnetisation that leads to instabilities during free precession. We recently demonstrated that a multi-echo NMR sequence, based on the magic sandwich pulse scheme developed for solid-state NMR, can be used to stabilise the magnetisation against the effect of distant dipolar fields. Here, we report investigations of echo attenuation in an applied field gradient that show the potential of this NMR sequence for spin diffusion measurements at high magnetisation densities.

cond-mat.other

NMR Time Reversal as a Probe of Incipient Turbulent Spin Dynamics

We demonstrate time reversal of nuclear spin dynamics in highly magnetized dilute liquid 3He-4He mixtures through effective inversion of long-range dipolar interactions. These experiments, which involve using magic sandwich NMR pulse sequences to generate spin echoes, probe the spatiotemporal development of turbulent spin dynamics and promise to serve as a versatile tool for the study and control of dynamic magnetization instabilities. We also show that a repeated magic sandwich pulse sequence can be used to dynamically stabilize modes of nuclear precession that are otherwise intrinsically unstable. To date, we have extended the effective precession lifetimes of our magnetized samples by more than three orders of magnitude.

cond-mat.other

NMR measurements of hyperpolarized 3He gas diffusion in high porosity silica aerogels

Hyperpolarized 3He is used to nondestructively probe by NMR the structure of custom-made and commercial silica aerogels (97% and 98.5% porous). Large spin-echo signals are obtained at room temperature and very low magnetic field (2mT) even with small mounts of gas. Attenuation induced by applied field gradients results from the combined effects of gas diffusion and confinement by the porous medium on atomic motion. Nitrogen is used as a buffer gas to reach equivalent 3He pressures ranging from 5 mbars to 3.5 bars. The observed pressure dependence suggests a non-uniform structure of the aerogels on length scales up to tens of micrometers. A description by broad phenomenological distributions of mean free paths is proposed, and quantitatively discussed by comparison to numerical calculations. The investigated aerogel samples exhibit different effective diffusion characteristics despite comparable nominal porosities.

cond-mat.mtrl-sci

Metastability Exchange Optical Pumping of Helium-3 at High Pressures and 1.5 T: Comparison of two Optical Pumping Transitions

At low magnetic field, metastability exchange optical pumping of helium-3 is known to provide high nuclear polarizations for pressures around 1 mbar. In a recent paper, we demonstrated that operating at 1.5 T can significantly improve the results of metastability exchange optical pumping at high pressures. Here, we compare the performances of two different optical pumping lines at 1.5 T, and show that either the achieved nuclear polarization or the production rate can be optimized.

physics.atom-ph

Polarized Helium to Image the Lung

The main findings of the european PHIL project (Polarised Helium to Image the Lung) are reported. State of the art optical pumping techniques for polarising ^3He gas are described. MRI methodological improvements allow dynamical ventilation images with a good resolution, ultimately limited by gas diffusion. Diffusion imaging appears as a robust method of lung diagnosis. A discussion of the potential advantage of low field MRI is presented. Selected PHIL results for emphysema are given, with the perspectives that this joint work opens up for the future of respiratory medicine.

physics.med-ph

High nuclear polarization of helium-3 at low and high pressure by metastability exchange optical pumping at 1.5 Tesla

We perform metastability exchange optical pumping of helium-3 in a strong magnetic field of 1.5 T. The achieved nuclear polarization, from 80% at 1.33 mbar to 25% at 67 mbar, shows a substantial improvement at high pressures with respect to standard low-field optical pumping. The specific mechanisms of metastability exchange optical pumping at high field are investigated, advantages and intrinsic limitations are discussed. From a practical point of view, our results open the way to alternative technological solutions for polarized helium-3 applications and in particular for magnetic resonance imaging of human lungs.

physics.atom-ph

A broadband Ytterbium-doped tunable fiber laser for 3He optical pumping at 1083 nm

Large amounts of hyperpolarized 3He gas with high nuclear polarization rates are required for use in neutron spin filters or nuclear magnetic resonance imaging of human lung. Very high efficiency can be obtained by metastability exchange optical pumping using multimode lasers to excite the 23S-23P transition at 1083 nm. Broadband Ytterbium-doped tunable fiber lasers have been designed for that particular application. Different options for the architecture of the fiber oscillator are presented and compared. Emphasis is given to a linear cavity configuration that includes a high reflectivity fiber mirror and a low reflectivity tunable fiber Bragg grating. Optical measurements are performed to finely characterize the spectral behavior of the lasers. Atomic response is also quantitatively probed to assess the optimal design of the oscillator for optical pumping. Multimode operation matching the 2 GHz Doppler-broadened helium resonance line and tunability over more than 200 GHz are demonstrated. Boosting the output of this fiber laser with a Yb-doped fiber power amplifier, all-fiber devices are built to provide robust, high power turn-key sources at 1083 nm for improved production of laser polarized 3He.

physics.atom-ph

In-Vivo NMR of Hyperpolarized Helium-3 in the Human Lung at Very Low Magnetic Fields

We present NMR measurements of the diffusion of hyperpolarized helium-3 in the human lung performed at fields much lower than those of conventional MRI scanners. The measurements were made on standing subjects using homebuilt apparatus operating at 3 mT. Oxygen-limited transverse relaxation (T2 up to 15-35 s) could be measured in-vivo. Accurate global diffusion measurements have been performed in-vivo and in-vitro. 1D ADC mapping with high SNR demonstrates the real possibility of performing quality lung imaging at extremely low fields.

physics.med-ph