SearcharxivSearch

arXiv subjects

Q. Zeng

Publications and source records attributed to Q. Zeng.

At least 19 recordsLinked to original sources

Experimental Verification of Demon-Involved Fluctuation Theorems

The limit of energy saving in the control of small systems has recently attracted much interest due to the concept refinement of the Maxwell demon. Inspired by a newly proposed set of fluctuation theorems, we report the first experimental verification of these equalities and inequalities in a ultracold 40Ca ion system, confirming the intrinsic nonequilibrium in the system due to involvement of the demon. Based on elaborately designed demon-involved control protocols, such as the Szilard engine protocol, we provide experimentally quantitative evidence of the dissipative information, and observe tighter bounds of both the extracted work and the demon's efficacy than the limits predicted by the Sagawa-Ueda theorem. Our results substantiate a close connection between the physical nature of information and nonequilibrium processes at the microscale, which help further understanding the thermodynamic characteristics of information and the optimal design of nanoscale and smaller systems.

quant-ph

Ground-state mass of $^{22}$Al and test of state-of-the-art \textit{ab initio} calculations

The ground-state mass excess of the $T_{z}=-2$ drip-line nucleus $^{22}$Al is measured for the first time to be $18103(10)$ keV using the newly-developed B$\rho$-defined isochronous mass spectrometry method at the cooler storage ring in Lanzhou. The new mass excess value allowed us to determine the excitation energies of the two low-lying $1^+$ states in $^{22}$Al with significantly reduced uncertainties of 51 keV. Comparing to the analogue states in its mirror nucleus $^{22}$F, the mirror energy differences of the two $1^+$ states in the $^{22}$Al-$^{22}$F mirror pair are determined to be $-625(51)$ keV and $-330(51)$ keV, respectively. The excitation energies and the mirror energy differences are used to test the state-of-the-art \textit{ab initio} valence-space in-medium similarity renormalization group calculations with four sets of interactions derived from the chiral effective field theory. The mechanism leading to the large mirror energy differences is investigated and attributed to the occupation of the $\pi s_{1/2}$ orbital.

nucl-ex

$B\rho$-defined isochronous mass spectrometry: a new approach for high-precision mass measurements of short-lived nuclei

A novel technique for broadband high-precision mass measurements of short-lived exotic nuclides is reported. It is based on the isochronous mass spectrometry (IMS) and realizes simultaneous determinations of revolution time and velocity of short-lived stored ions at the cooler storage ring CSRe in Lanzhou. The new technique, named as the $B\rho$-defined IMS or $B\rho$-IMS, boosts the efficiency, sensitivity, and accuracy of mass measurements, and is applied here to measure masses of neutron-deficient $fp$-shell nuclides. In a single accelerator setting, masses of $^{46}$Cr, $^{50}$Fe and $^{54}$Ni are determined with relative uncertainties of (5~-~6)$\times10^{-8}$, thereby improving the input data for testing the unitarity of the Cabibbo-Kobayashi-Maskawa quark mixing matrix. This is the technique of choice for future high-precision measurements of the most rarely produced shortest-lived nuclides.

physics.ins-det

$B\rho$-defined Isochronous Mass Spectrometry and Mass Measurements of $^{58}$Ni Fragments

A novel isochronous mass spectrometry, termed as $B\rho$-defined IMS, is established at the experimental cooler-storage ring CSRe in Lanzhou. Its potential has been studied through high precision mass measurements of $^{58}$Ni projectile fragments. Two time-of-flight detectors were installed in one of the straight sections of CSRe, thus enabling simultaneous measurements of the velocity and the revolution time of each stored short-lived ion. This allows for calculating the magnetic rigidity $B\rho$ and the orbit length $C$ of each ion. The accurate $B\rho(C)$ function has been constructed, which is a universal calibration curve used to deduce the masses of the stored nuclides. The sensitivity to single stored ions, quickness, and background-free characteristics of the method are ideally suited to address nuclides with very short lifetimes and tiniest production yields. In the limiting case of just a single particle, the attained mass resolving power allows one us to determine its mass-over-charge ratio $m/q$ with a remarkable precision of merely $\sim5$ keV. Masses of $T_z = -3/2$ fp-shell nuclides are re-determined with high accuracy, and the validity of the isospin multiplet mass equation is tested up to the heaviest isospin quartet with $A = 55$. The new masses are also used to investigate the mirror symmetry of empirical residual proton-neutron interactions.

nucl-ex

Systematic trends of neutron skin thickness versus relative neutron excess

Available experimental neutron skin thicknesses of even-even stable Ca, Ni, Sn, Pb, and Cd isotopes are evaluated, and separate trends of neutron skin thickness versus relative neutron excess $\delta=(N-Z)/A$ are firstly observed for different isotopic chains. This phenomenon is quantitatively reproduced by the deformed Skyrme Hartree-Fock $+$ BCS model with SLy4 force.

nucl-th

Particle identification and revolution time corrections for the isochronous mass spectrometry in storage rings

In the isochronous mass spectrometry (IMS) performed at storage rings, masses of short-lived nuclides are determined through precision measurements of their mean revolution times. However, the distribution of revolution times could be seriously deteriorated by instabilities of the ring's magnetic fields. This becomes a significant obstacle for the particle identifications and mass determinations. A data analysis method is described in this paper which is able to largely remove the uncertainties caused by the magnetic field instabilities in the particle identifications and the mean revolution times. We show that this method is very effective for the IMS experiments even when the magnetic fields of a storage ring vary slowly up to a level of $\Delta B/B\sim 10^{-4}$.

nucl-ex

Mass measurements for $T_{z}=-2$ $fp$-shell nuclei $^{40}$Ti, $^{44}$Cr, $^{46}$Mn, $^{48}$Fe, $^{50}$Co and $^{52}$Ni

By using isochronous mass spectrometry (IMS) at the experimental cooler storage ring CSRe, masses of short-lived $^{44}$Cr, $^{46}$Mn, $^{48}$Fe, $^{50}$Co and $^{52}$Ni were measured for the first time and the precision of the mass of $^{40}$Ti was improved by a factor of about 2. Relative precisions of $\delta m/m=(1-2)\times$10$^{-6}$ have been achieved. Details of the measurements and data analysis are described. The obtained masses are compared with the Atomic-Mass Evaluation 2016 (AME$^{\prime}$16) and with theoretical model predictions. The new mass data enable us to extract the higher order coefficients, $d$ and $e$, of the quartic form of the isobaric multiplet mass equation (IMME) for the $fp$-shell isospin quintets. Unexpectedly large $d$- and $e$-values for $A=44$ quintet are found. By re-visiting the previous experimental data on $\beta$-delayed protons from $^{44}$Cr decay, it is suggested that the observed anomaly could be due to the misidentification of the $T=2$, $J^\pi=0^{+}$ isobaric analog state (IAS) in $^{44}$V.

nucl-ex

Masses of ground and isomeric states of $^{101}$In and configuration-dependent shell evolution in odd-$A$ indium isotopes

We report first precision mass measurements of the $1/2^-$ isomeric and $9/2^+$ ground states of $^{101}$In. The determined isomeric excitation energy continues a smooth trend of odd-$A$ indium isotopes up to the immediate vicinity of $N=50$ magic number. This trend can be confirmed by dedicated shell model calculations only if the neutron configuration mixing is considered. We find that the single particle energies are different for different states of the same isotope. The presented configuration-dependent shell evolution, type II shell evolution, in odd-$A$ nuclei is discussed for the first time. Our results will facilitate future studies of single-particle neutron states.

nucl-ex

Masses of neutron-rich $^{\operatorname{52-54}}$Sc and $^{54,56}$Ti nuclides: The $N=32$ subshell closure in scandium

Isochronous mass spectrometry has been applied in the storage ring CSRe to measure the masses of the neutron-rich $^{\operatorname{52-54}}$Sc and $^{54,56}$Ti nuclei. The new mass excess values $ME$($^{52}$Sc) $=$ $-40525(65)$ keV, $ME$($^{53}$Sc) $=$ $-38910(80)$ keV, and $ME$($^{54}$Sc) $=$ $-34485(360)$ keV, deviate from the Atomic Mass Evaluation 2012 by 2.3$σ$, 2.8$σ$, and 1.7$σ$, respectively. These large deviations significantly change the systematics of the two-neutron separation energies of scandium isotopes. The empirical shell gap extracted from our new experimental results shows a significant subshell closure at $N = 32$ in scandium, with a similar magnitude as in calcium. Moreover, we present $ab$ $initio$ calculations using the valence-space in-medium similarity renormalization group based on two- and three-nucleon interactions from chiral effective field theory. The theoretical results confirm the existence of a substantial $N = 32$ shell gap in Sc and Ca with a decreasing trend towards lighter isotones, thus providing a consistent picture of the evolution of the $N = 32$ magic number from the $pf$ into the $sd$ shell.

nucl-ex

Improving the resolving power of Isochronous Mass Spectrometry by employing an in-ring mechanical slit

Isochronous Mass Spectrometry (IMS) in heavy-ion storage rings is an excellent experimental method for precision mass measurements of exotic nuclei. In the IMS, the storage ring is tuned in a special isochronous ion-optical mode. Thus, the mass-over-charge ratios of the stored ions are directly reflected by their respective revolution times in first order. However, the inevitable momentum spread of secondary ions increases the peak widths in the measured spectra and consequently limits the achieved mass precision. In order to achieve a higher mass resolving power, the ring aperture was reduced to 60 mm by applying a mechanical slit system at the dispersive straight section. The momentum acceptance was reduced as well as better isochronous conditions were achieved. The results showed a significant improvement of the mass resolving power reaching $5.2 \times 10^{5}$, though at the cost of about 40\% ion loss.

nucl-ex

Experimental Investigation of the Transition Energy $γ_t$ in the Isochronous Mode of the HIRFL-CSRe

The Isochronous Mass Spectrometry (IMS) based on storage rings is a powerful technique for mass measurement of short-lived exotic nuclei. The transition energy $γ_t$ of the storage ring is a vital parameter of the IMS technique. It is difficult to measure the $γ_t$ and its relation to momentum spread or circulating length, especially to monitor the variation of $γ_t$ during experiments. An experimental investigation on the $γ_t$ has been performed for the IMS experiment at the Cooler Storage Ring of the Heavy Ion Research Facility in Lanzhou (HIRFL-CSRe). With the velocity measured by two time-of-flight (TOF) detectors, the $γ_t$ as a function of orbital length can be determined. The influences of higher order magnetic field components on the $γ_t$ function were inferred for isochronous correction. This paper introduces and investigates the influence of dipole magnetic fields, quadrupole magnetic fields and sextupole magnetic fields on the $γ_t$ function. With the quadrupole magnets and sextupole magnets corrections, a mass resolution of 171332 (FWHM) and $σ(T)/T=1.34\times10^{-6}$ were reached, which shall be compared with 31319 (FWHM) and $σ(T)/T=7.35\times10^{-6}$ obtained without correction.

physics.acc-ph

Application of isochronous mass spectrometry for the study of angular momentum population in projectile fragmentation reactions

Isochronous mass spectrometry was applied to measure isomeric yield ratios of fragmentation reaction products. This approach is complementary to conventional gamma-ray spectroscopy in particular for measuring yield ratios for long-lived isomeric states. Isomeric yield ratios for the high-spin I = 19/2 states in the mirror nuclei 53Fe and 53Co are measured to study angular momentum population following the projectile fragmentation of 78Kr at energies of 480A MeV on a beryllium target. The 19/2 state isomeric ratios of 53Fe produced from different projectiles in the literature have also been extracted as a function of mass number difference between projectile and fragment (mass loss). The results are compared to ABRABLA07 model calculations. The isomeric ratios of 53Fe produced using different projectiles suggest that the theory underestimates not only the previously reported dependence on the spin but also the dependence on the mass loss.

nucl-ex

A method to measure the transition energy $γ_{t}$ of the isochronously tuned storage ring

The Isochronous Mass Spectrometry (IMS) is a powerful technique developed in heavy-ion storage rings for measuring masses of very short-lived exotic nuclei. The IMS is based on the isochronous setting of the ring. One of the main parameters of this setting is the transition energy $γ_{t}$. %The transition energy $γ_{t}$ plays an important role in the isochronous mass spectrometry (IMS). It has been a challenge to determine the $γ_{t}$ and especially to monitor the variation of $γ_{t}$ during experiments. In this paper we introduce a method to measure the $γ_{t}$ online during IMS experiments by using the acquired experimental data. Furthermore, since the storage ring has (in our context) a relatively large momentum acceptance, the variation of the $γ_{t}$ across the ring acceptance is a source of systematic uncertainty of measured masses. With the installation of two time-of-flight (TOF) detectors, the velocity of each stored ion and its revolution time are simultaneously available for the analysis. These quantities enabled us to determine the $γ_{t}$ as a function of orbital length in the ring. The presented method is especially important for future IMS experiments planned at the new-generation storage ring facilities FAIR in Germany and HIAF in China.

physics.ins-det

Isochronous mass measurements of $T_z=-1$ $fp$-shell nuclei from projectile fragmentation of $^{58}$Ni

Atomic masses of seven $T_z=-1$, $fp$-shell nuclei from $^{44}$V to $^{56}$Cu and two low-lying isomers, $^{44m}$V ($J^π=6^+$) and $^{52m}$Co ($J^π=2^+$), have been measured with relative precisions of $1-4\times 10^{-7}$ with Isochronous Mass Spectrometry (IMS) at CSRe. The masses of $^{56}$Cu, $^{52g,52m}$Co, and $^{44m}$V were measured for the first time in this experiment. The Mass Excesses ($ME^{\prime}$s) of $^{44}$V, $^{48}$Mn, $^{50}$Fe, and $^{54}$Ni are determined with an order of magnitude improved precision compared to the literature values. $^{52g,52m}$Co and $^{56}$Cu are found to be $370$~keV and $400$~keV more bound, respectively, while $^{44g,44m}$V are $\sim 300$~keV less bound than the extrapolations in the Atomic-Mass Evaluation 2012 (AME$^{\prime}$12). The masses of the four $T_z=-1/2$ nuclei $^{45}$V, $^{47}$Cr, $^{49}$Mn, and $^{51}$Fe are re-determined to be in agreement, within the experimental errors, with the recent JYFLTRAP measurements or with the previous IMS measurements in CSRe. Details of the measurements and data analysis are described, and the impact of the new $ME$ values on different aspects in nuclear structure are investigated and discussed.

nucl-ex

The Masses of the $T_z=-3/2$ Nuclei $^{27}$P and $^{29}$S

Isochronous mass spectrometry has been applied in the storage ring CSRe to measure the masses of the $T_z=-3/2$ nuclei $^{27}$P and $^{29}$S. The new mass excess value $ME$($^{29}$S) $=-3094(13)$~keV is 66(52)~keV larger than the result of the previous $^{32}$S($^3$He,$^{6}$He)$^{29}$S reaction measurement in 1973 and a factor of 3.8 more precise. The new result for $^{29}$S, together with those of the $T=3/2$ isobaric analog states (IAS) in $^{29}$P, $^{29}$Si, and $^{29}$Al, fit well into the quadratic form of the Isobaric Multiplet Mass Equation IMME. The mass excess of $^{27}$P has been remeasured to be $ME(^{27}$P$)=-685(42)$ keV. By analyzing the linear and quadratic coefficients of the IMME in the $T_z=-3/2$ $sd$-shell nuclei, it was found that the ratio of the Coulomb radius parameters is $R\approx0.96$ and is nearly the same for all $T=3/2$ isospin multiplets. Such a nearly constant $R$-value, apparently valid for the entire light mass region with $A>9$, can be used to set stringent constraints on the isovector and isotensor components of the isospin non-conserving forces in theoretical calculations.

nucl-ex

First application of combined isochronous and Schottky mass spectrometry: Half-lives of fully ionized 49Cr24+ and 53Fe26+ atoms

Lifetime measurements of b -decaying highly charged ions have been performed in the storage ring CSRe by applying the isochronous Schottky mass spectrometry. The fully ionized 49Cr and 53Fe ions were produced in projectile fragmentation of 58Ni primary beam and were stored in the CSRe tuned into the isochronous ion-optical mode. The new resonant Schottky detector was applied to monitor the intensities of stored uncooled 49Cr24+ and 53Fe26+ ions. The extracted half-lives T1/2(49Cr24+) = 44.0(27) min and T1/2(53Fe26+) = 8.47(19) min are in excellent agreement with the literature half-life values corrected for the disabled electron capture branchings. This is an important proof-of-principle step towards realizing the simultaneous mass and lifetime measurements on exotic nuclei at the future storage ring facilities.

nucl-ex

Mass Measurements of Neutron-Deficient Y, Zr, and Nb Isotopes and Their Impact on $rp$ and $νp$ Nucleosynthesis Processes

Using isochronous mass spectrometry at the experimental storage ring CSRe in Lanzhou, the masses of $^{82}$Zr and $^{84}$Nb were measured for the first time with an uncertainty of $\sim 10$ keV, and the masses of $^{79}$Y, $^{81}$Zr, and $^{83}$Nb were re-determined with a higher precision. %The latter differ significantly from their literature values. The latter are significantly less bound than their literature values. Our new and accurate masses remove the irregularities of the mass surface in this region of the nuclear chart. Our results do not support the predicted island of pronounced low $α$ separation energies for neutron-deficient Mo and Tc isotopes, making the formation of Zr-Nb cycle in the $rp$-process unlikely. The new proton separation energy of $^{83}$Nb was determined to be 490(400)~keV smaller than that in the Atomic Mass Evaluation 2012. This partly removes the overproduction of the $p$-nucleus $^{84}$Sr relative to the neutron-deficient molybdenum isotopes in the previous $νp$-process simulations.

nucl-ex

Identification of the Lowest $T=2$, $J^{π=}0^+$ Isobaric Analog State in $^{52}$Co and Its Impact on the Understanding of $β$-Decay Properties of $^{52}$Ni

Masses of $^{52g,52m}$Co were measured for the first time with an accuracy of $\sim 10$ keV, an unprecedented precision reached for short-lived nuclei in the isochronous mass spectrometry. Combining our results with the previous $β$-$γ$ measurements of $^{52}$Ni, the $T=2$, $J^π=0^+$ isobaric analog state (IAS) in $^{52}$Co was newly assigned, questioning the conventional identification of IASs from the $β$-delayed proton emissions. Using our energy of the IAS in $^{52}$Co, the masses of the $T=2$ multiplet fit well into the Isobaric Multiplet Mass Equation. We find that the IAS in $^{52}$Co decays predominantly via $γ$ transitions while the proton emission is negligibly small. According to our large-scale shell model calculations, this phenomenon has been interpreted to be due to very low isospin mixing in the IAS.

nucl-ex