Searcharxiv⌕ Search

arXiv subjects

Q. Zeng

Publications and source records attributed to Q. Zeng.

21 records · Page 2Linked to original sources

An improvement of isochronous mass spectrometry: Velocity measurements using two time-of-flight detectors

Isochronous mass spectrometry (IMS) in storage rings is a powerful tool for mass measurements of exotic nuclei with very short half-lives down to several tens of microseconds, using a multicomponent secondary beam separated in-flight without cooling. However, the inevitable momentum spread of secondary ions limits the precision of nuclear masses determined by using IMS. Therefore, the momentum measurement in addition to the revolution period of stored ions is crucial to reduce the influence of the momentum spread on the standard deviation of the revolution period, which would lead to a much improved mass resolving power of IMS. One of the proposals to upgrade IMS is that the velocity of secondary ions could be directly measured by using two time-of-flight (double TOF) detectors installed in a straight section of a storage ring. In this paper, we outline the principle of IMS with double TOF detectors and the method to correct the momentum spread of stored ions.

physics.ins-det↗

Accurate correction of magnetic field instabilities for high-resolution isochronous mass measurements in storage rings

Isochronous mass spectrometry (IMS) in storage rings is a successful technique for accurate mass measurements of short-lived nuclides with relative precision of about $10^{-5}-10^{-7}$. Instabilities of the magnetic fields in storage rings are one of the major contributions limiting the achievable mass resolving power, which is directly related to the precision of the obtained mass values. A new data analysis method is proposed allowing one to minimise the effect of such instabilities. The masses of the previously measured at the CSRe $^{41}$Ti, $^{43}$V, $^{47}$Mn, $^{49}$Fe, $^{53}$Ni and $^{55}$Cu nuclides were re-determined with this method. An improvement of the mass precision by a factor of $\sim 1.7$ has been achieved for $^{41}$Ti and $^{43}$V. The method can be applied to any isochronous mass experiment irrespective of the accelerator facility. Furthermore, the method can be used as an on-line tool for checking the isochronous conditions of the storage ring.

nucl-ex↗

Car accidents and number of stopped cars due to road blockage on a one-lane highway

Within the framework of a simple model of car traffic on a one-lane highway, we study the probability for car accidents to occur when drivers do not respect the safety distance between cars, and, as a result of the blockage during the time $T$ necessary to clear the road, we determine the number of stopped cars as a function of car density. We give a simple theory in good agreement with our numerical simulations.

adap-org↗