SearcharxivSearch

arXiv subjects

Qing Lin

Publications and source records attributed to Qing Lin.

At least 37 records · Page 2Linked to original sources

Unforgettable Lessons from Forgettable Images: Intra-Class Memorability Matters in Computer Vision

We introduce intra-class memorability, where certain images within the same class are more memorable than others despite shared category characteristics. To investigate what features make one object instance more memorable than others, we design and conduct human behavior experiments, where participants are shown a series of images, and they must identify when the current image matches the image presented a few steps back in the sequence. To quantify memorability, we propose the Intra-Class Memorability score (ICMscore), a novel metric that incorporates the temporal intervals between repeated image presentations into its calculation. Furthermore, we curate the Intra-Class Memorability Dataset (ICMD), comprising over 5,000 images across ten object classes with their ICMscores derived from 2,000 participants' responses. Subsequently, we demonstrate the usefulness of ICMD by training AI models on this dataset for various downstream tasks: memorability prediction, image recognition, continual learning, and memorability-controlled image editing. Surprisingly, high-ICMscore images impair AI performance in image recognition and continual learning tasks, while low-ICMscore images improve outcomes in these tasks. Additionally, we fine-tune a state-of-the-art image diffusion model on ICMD image pairs with and without masked semantic objects. The diffusion model can successfully manipulate image elements to enhance or reduce memorability. Our contributions open new pathways in understanding intra-class memorability by scrutinizing fine-grained visual features behind the most and least memorable images and laying the groundwork for real-world applications in computer vision. We will release all code, data, and models publicly.

cs.CV

Make Me Happier: Evoking Emotions Through Image Diffusion Models

Despite the rapid progress in image generation, emotional image editing remains under-explored. The semantics, context, and structure of an image can evoke emotional responses, making emotional image editing techniques valuable for various real-world applications, including treatment of psychological disorders, commercialization of products, and artistic design. First, we present a novel challenge of emotion-evoked image generation, aiming to synthesize images that evoke target emotions while retaining the semantics and structures of the original scenes. To address this challenge, we propose a diffusion model capable of effectively understanding and editing source images to convey desired emotions and sentiments. Moreover, due to the lack of emotion editing datasets, we provide a unique dataset consisting of 340,000 pairs of images and their emotion annotations. Furthermore, we conduct human psychophysics experiments and introduce a new evaluation metric to systematically benchmark all the methods. Experimental results demonstrate that our method surpasses all competitive baselines. Our diffusion model is capable of identifying emotional cues from original images, editing images that elicit desired emotions, and meanwhile, preserving the semantic structure of the original images. All code, model, and dataset are available at GitHub.

cs.CV

Precise Measurement of $^{216}$Po Half-life with Exact Parent-daughter Pairing in PandaX-4T

We report a precise measurement of $^{216}\rm Po$ half-life using the PandaX-4T liquid xenon time projection chamber (TPC). $^{220}\rm Rn $, emanating from a $^{228}\rm Th $ calibration source, is injected to the detector and undergoes successive $α$ decays, first to $^{216}\rm Po$ and then to $^{212}\rm Pb$. PandaX-4T detector measures the 5-dimensional (5D) information of each decay, including time, energy, and 3-dimensional positions. Therefore, we can identify the $^{220}\rm Rn $ and $^{216}\rm Po$ decay events and pair them exactly to extract the lifetime of each $^{216}\rm Po$. With a large data set and high-precision $^{220}\rm $Rn-$^{216}\rm $Po pairing technique, we measure the $^{216}\rm Po$ half-life to be $143.7\pm0.5$ ms, which is the most precise result to date and agrees with previously published values. The leading precision of this measurement demonstrates the power of 5D calorimeter and the potential of exact parent-daughter pairing in the xenon TPC.

nucl-ex

LVPNet: A Latent-variable-based Prediction-driven End-to-end Framework for Lossless Compression of Medical Images

Autoregressive Initial Bits is a framework that integrates sub-image autoregression and latent variable modeling, demonstrating its advantages in lossless medical image compression. However, in existing methods, the image segmentation process leads to an even distribution of latent variable information across each sub-image, which in turn causes posterior collapse and inefficient utilization of latent variables. To deal with these issues, we propose a prediction-based end-to-end lossless medical image compression method named LVPNet, leveraging global latent variables to predict pixel values and encoding predicted probabilities for lossless compression. Specifically, we introduce the Global Multi-scale Sensing Module (GMSM), which extracts compact and informative latent representations from the entire image, effectively capturing spatial dependencies within the latent space. Furthermore, to mitigate the information loss introduced during quantization, we propose the Quantization Compensation Module (QCM), which learns the distribution of quantization errors and refines the quantized features to compensate for quantization loss. Extensive experiments on challenging benchmarks demonstrate that our method achieves superior compression efficiency compared to state-of-the-art lossless image compression approaches, while maintaining competitive inference speed. The code is at https://github.com/scy-Jackel/LVPNet.

eess.IV

Measurement of two-neutrino double electron capture half-life of $^{124}$Xe with PandaX-4T

Detailed studies of two-neutrino double electron capture (2$ν$DEC) is a crucial step towards searching for the neutrino-less mode to explore the Majorana nature of neutrinos. We have measured precisely the half-life of the 2$ν$DEC process in $^{124}$Xe, utilizing a total exposure of 1.73 tonne$\cdot$year from the commissioning run and the first science run of the PandaX-4T experiment. A time-dependent background model in the $\mathcal{O}$(10 keV) energy is constructed for the first time in PandaX-4T data. With an unbinned maximum likelihood fit, we determine the half-life of the 2$ν$DEC process to be $(1.03\pm0.15_{\rm stat}\pm0.08_{\rm sys})\times 10^{22}$$\,$yr. Furthermore, we have evaluated the branching ratio for both electrons captured from the $K$ shell ($KK$) to be $(65\pm5)\%$, which aligns with the $^{124}$Xe nuclear model calculations within 1.8$\,$$σ$.

nucl-ex

Search for Solar Boosted Dark Matter Particles at the PandaX-4T Experiment

We present a novel constraint on light dark matter utilizing $1.54$ tonne$\cdot$year of data acquired from the PandaX-4T dual-phase xenon time projection chamber. This constraint is derived through detecting electronic recoil signals resulting from the interaction with solar-enhanced dark matter flux. Low-mass dark matter particles, lighter than a few MeV/$c^2$, can scatter with the thermal electrons in the Sun. Consequently, with higher kinetic energy, the boosted dark matter component becomes detectable via contact scattering with xenon electrons, resulting in a few keV energy deposition that exceeds the threshold of PandaX-4T. We calculate the expected recoil energy in PandaX-4T considering the Sun's acceleration and the detection capabilities of the xenon detector. The first experimental search results using the xenon detector yield the most stringent cross-section of $3.51 \times 10^{-39}~\mathrm{cm}^2$ at $0.08~\mathrm{MeV}$/$c^2$ for a solar boosted dark matter mass ranging from $0.02$ to $10~ \mathrm{MeV}$/$c^2$, achieving a 23 fold improvement compared with earlier experimental studies.

hep-ex

Pre-study of a Li2MoO4 based bolometer for 100Mo neutrinoless double beta decay experiment in China

The cryogenic phonon scintillating bolometer is a promising and extremely attractive option to search for the nuclide neutrinoless double beta decay. In this paper, a pre-study of bolometer based on Li2MoO4 (LMO) crystal is presented, in which the properties of the LMO crystal at the low temperature, including scintillation characteristics and specific heat, are investigated in detail. The excitation spectrum and light yield are measured from the room temperature down to 10 K, and heat capacity is measured down to temperature of O(200) mK. Furthermore, a (2 cm)3 cubic LMO based bolometer is manufactured and tested at ultra-low mK-level temperature in a ground-above cryostat platform, and a good energy resolution is achieved. The studies laid a foundation to manufacture the bolometer detector in China and conduct neutrinoless double beta decay research at the China Jinping Underground Laborator

physics.ins-det

Search for New Particles with Flying Quantum Sensors in Space

Recent advancements in space science and technologies offer exciting prospects for investigating novel research that is unattainable within terrestrial laboratories. Here we propose the implementation of space-based quantum sensing to explore ultralight new particles beyond the standard model. The central idea involves probing long-range interactions between spin ensembles of space quantum sensors and the particles residing within Earth, mediated by ultralight particles. We show that such interactions can be substantially enhanced in space platforms and thus increase the search sensitivity. In contrast to their terrestrial counterparts, space-based quantum searches exhibit remarkable velocity enhancements, approaching the first cosmic speed, and thus enables the exploration of unexplored parameter space concerning ultralight new particles. Furthermore, the substantial abundance of electrons and nucleons within Earth plays a crucial role in extending the scope of our mission. Our projected search sensitivity can surpass the sensitivities of both terrestrial experiments and proposals by up to approximately 7 orders of magnitude. We also briefly discuss other space mission, including ``space-ground integrated" network of quantum sensors for dark matter searches.

quant-ph

Search for Double Beta Decay of $^{136}$Xe to the $0^+_1$ Excited State of $^{136}$Ba with PandaX-4T

We perform a search of double beta decay of $^{136}$Xe to the excited state, $0^+_1$, of $^{136}$Ba (2$νββ$-0$_1^+$), using the dual-phase xenon detector of PandaX-4T with the first 94.9-day commissioning data. The multi-site events are reconstructed up to the MeV energy scale, which helps to improve the background model significantly. The background contribution from the stainless steel platform outside PandaX-4T cryostat is evaluated for the first time. No significant evidence for 2$νββ$-$0_1^+$ is observed, resulting in a lower limit on half-life of $7.5 \times 10^{22}$ yr at the 90% confidence level. This is the first experimental limit on such a rare decay in a natural xenon-based detector.

nucl-ex

Search for MeV-Scale Axionlike Particles and Dark Photons with PandaX-4T

Axionlike particles (ALPs) and dark photons (DPs) are viable dark matter particle candidates. We have searched for possible ALP/DP signals in the PandaX-4T liquid xenon detector using 440 kg$\cdot$yr of data. A binned likelihood fit is constructed to search for possible mono-energetic peaks induced by the absorption processes between ALPs/DPs and atomic electrons of xenon. A detailed temporal model of decays associated with xenon isotopes is introduced to constrain the number of background events. No signal excess over background expectations is observed, and we have established the most stringent exclusion limits for most ALP/DP masses across the range of 150 keV/$c^2$ to 1 MeV/$c^2$. The improvement is particularly significant within the mass range of \text{150-400}~keV/$c^2$, with the average factor of 3.5 compared to previous results.

hep-ex

Room temperature mass sensing based on nonlinear optomechanical dynamics: membrane-in-the-middle versus suspended membrane

How to weigh something as precise as possible is a constant endeavor for human being, and mass sensing has been essential to scientific research and many other aspects of modern society. In this work, we explore a special approach to mass sensing, which is purely based on the classical nonlinear dynamics of cavity optomechanical systems. We consider two types of systems, the mechanical resonator as a suspended membrane inside optical cavity or as a larger movable membrane that separates the optical cavity into two parts. Under a driving laser field with two tones satisfying a specific frequency condition, both systems enter a special dynamical pattern correlating the mechanical oscillation and the sidebands of oscillatory cavity field. After adding the nano-particle, which has its mass δm to be measured, to the mechanical membrane as the detector, the cavity field sidebands will exhibit detectable changes, so that the tiny mass δm can be deduced from the measured sideband intensities. For the latter system with a membrane in the middle, one can apply an additional single-tone laser field to magnify the modified sidebands much further, achieving an ultra-high sensitivity (δm/m) \sim 10^{-11} ($m$ is the mass of the membrane), even given a moderate mechanical quality factor. The operation range of the sensors is very wide, covering 7 or 8 orders of magnitudes. Moreover, a particular advantage of this type of mass sensors comes from the robustness of the realized dynamical pattern against thermal noise, and it enables such mass sensors to work well at room temperature.

physics.optics

Position reconstruction and surface background model for the PandaX-4T detector

We report the position reconstruction methods and surface background model for the PandaX-4T dark matter direct search experiment. This work develops two position reconstruction algorithms: template matching (TM) method and photon acceptance function (PAF) method. Both methods determine the horizontal position of events based on the light pattern of secondary scintillation collected by the light sensors. After a comprehensive evaluation of resolution, uniformity, and robustness, the PAF method was selected for position reconstruction, while the TM method was employed for verification. The PAF method achieves a bulk event resolution of 1.0 mm and a surface event resolution of 4.4 mm for a typical $S2$ signal with a bottom charge of 1500 PE (about 14 keV). The uniformity is around 20\%. Robustness studies reveal average deviations of 5.1 mm and 8.8 mm for the commissioning run (Run0) and the first science run (Run1), respectively, due to the deactivation of certain PMTs. A data-driven surface background model is developed based on the PAF method. The surface background is estimated to be $0.09 \pm 0.06$ events for Run0 (0.54 tonne$\cdot$year) and $0.17 \pm 0.11$ events for Run1 (1.00 tonne$\cdot$year).

physics.ins-det

Dark Matter Search Results from 1.54 Tonne$\cdot$Year Exposure of PandaX-4T

In this letter, we report the dark matter search results from the commissioning run and the first science run of the PandaX-4T experiment. A blind analysis is carried out on the entire data set. The data processing is improved compared to previous work, unifying the low-level signal reconstruction in a wide energy range up to 120 keV. With a total exposure of 1.54 tonne$\cdot$year, no significant excess of nuclear recoil events is found. The lowest 90% confidence level exclusion on the spin-independent cross section is $1.6 \times 10^{-47}\,\mathrm{cm}^2$ at a dark matter mass of 40 GeV$/c^2$. Our results represent the most stringent constraint for a dark matter mass above 100 GeV$/c^2$.

hep-ex

Exploring New Physics with PandaX-4T Low Energy Electronic Recoil Data

New particles beyond the standard model of particle physics, such as axions, can be effectively searched through their interactions with electrons. We use the large liquid xenon detector PandaX-4T to search for novel electronic recoil signals induced by solar axions, neutrinos with anomalous magnetic moment, axionlike particles, dark photons, and light fermionic dark matter. A detailed background model is established using the latest datasets with 1.54 $\rm ton \cdot yr$ exposure. No significant excess above the background has been observed, and we have obtained competitive constraints for axion couplings, neutrino magnetic moment, and fermionic dark matter interactions.

hep-ex

Searching for Neutrinoless Double-Beta Decay of $^{136}$Xe with PandaX-4T

We report the search for neutrinoless double-beta decay of $^{136}$Xe from the PandaX-4T experiment with a 3.7-tonne natural xenon target. The data reconstruction and the background modeling are optimized in the MeV energy region. A blind analysis is performed with data from the commissioning run and the first science run. No significant excess of signal over the background is observed. A lower limit on the half-life of $^{136}$Xe neutrinoless double-beta decay is established to be $2.1 \times 10^{24}$~yr at the 90\% confidence level, with a $^{136}$Xe exposure of 44.6~kg$\cdot$year. Our result represents the most stringent constraint from a natural xenon detector to date.

nucl-ex

PandaX-xT: a Multi-ten-tonne Liquid Xenon Observatory at the China Jinping Underground Laboratory

We propose a major upgrade to the existing PandaX-4T experiment in the China Jinping Underground Laboratory. The new experiment, PandaX-xT, will be a multi-ten-tonne liquid xenon, ultra-low background, and general-purpose observatory. The full-scaled PandaX-xT contains a 43-tonne liquid xenon active target. Such an experiment will significantly advance our fundamental understanding of particle physics and astrophysics. The sensitivity of dark matter direct detection will be improved by nearly two orders of magnitude compared to the current best limits, approaching the so-called "neutrino floor" for a dark matter mass above 10 GeV/$c^2$, providing a decisive test to the Weakly Interacting Massive Particle paradigm. By searching for the neutrinoless double beta decay of $^{136}$Xe isotope in the detector, the effective Majorana neutrino mass can be measured to a [10 -- 41] meV/$c^2$ sensitivity, providing a key test to the Dirac/Majorana nature of neutrino s. Astrophysical neutrinos and other ultra-rare interactions can also be measured and searched for with an unprecedented background level, opening up new windows of discovery. Depending on the findings, PandaX-xT will seek the next stage upgrade utilizing isotopic separation on natural xenon.

hep-ex

Universal Scaling of Gap Dynamics in Percolation

Percolation is a cornerstone concept in physics, providing crucial insights into critical phenomena and phase transitions. In this study, we adopt a kinetic perspective to reveal the scaling behaviors of higher-order gaps in the largest cluster across various percolation models, spanning from latticebased to network systems, encompassing both continuous and discontinuous percolation. Our results uncover an inherent self-similarity in the dynamical process both for critical and supercritical phase, characterized by two independent Fisher exponents, respectively. Utilizing a scaling ansatz, we propose a novel scaling relation that links the discovered Fisher exponents with other known critical exponents. Additionally, we demonstrate the application of our theory to real systems, showing its practical utility in extracting the corresponding Fisher exponents. These findings enrich our understanding of percolation dynamics and highlight the robust and universal scaling laws that transcend individual models and extend to broader classes of complex systems.

cond-mat.stat-mech

Reactor neutrino liquid xenon coherent elastic scattering experiment

Coherent elastic neutrino-nucleus scattering (CEvNS) provides a unique probe for neutrino properties Beyond the Standard Model (BSM) physics. REactor neutrino LIquid xenon Coherent Scattering experiment (RELICS), a proposed reactor neutrino program using liquid xenon time projection chamber (LXeTPC) technology, aims to investigate the CEvNS process of antineutrinos off xenon atomic nuclei. In this work, the design of the experiment is studied and optimized based on Monte Carlo (MC) simulations. To achieve a sufficiently low energy threshold for CEvNS detection, an ionization-only analysis channel is adopted for RELICS. A high emission rate of delayed electrons after a big ionization signal is the major background, leading to an analysis threshold of 120 photo-electrons in the CEvNS search. The second largest background, nuclear recoils induced by cosmic-ray neutrons, is suppressed via a passive water shield. The physics potential of RELICS is explored with a 32 kg*yr exposure at a baseline of 25 m from a reactor core with a 3 GW thermal power. In an energy range of 120 to 300 PE, corresponding to an average nuclear recoil from 0.63 to 1.36 keV considering the liquid xenon response and detector-related effect, we expect 4639.7 CEvNS and 1687.8 background events. The sensitivity of RELICS to the weak mixing angle is investigated at a low momentum transfer. Our study shows that RELICS can further improve the constraints on the non-standard neutrino interaction (NSI) compared to the current best results.

hep-ex