Abstract

We report the position reconstruction methods and surface background model for the PandaX-4T dark matter direct search experiment. This work develops two position reconstruction algorithms: template matching (TM) method and photon acceptance function (PAF) method. Both methods determine the horizontal position of events based on the light pattern of secondary scintillation collected by the light sensors. After a comprehensive evaluation of resolution, uniformity, and robustness, the PAF method was selected for position reconstruction, while the TM method was employed for verification. The PAF method achieves a bulk event resolution of 1.0 mm and a surface event resolution of 4.4 mm for a typical $S2$ signal with a bottom charge of 1500 PE (about 14 keV). The uniformity is around 20\%. Robustness studies reveal average deviations of 5.1 mm and 8.8 mm for the commissioning run (Run0) and the first science run (Run1), respectively, due to the deactivation of certain PMTs. A data-driven surface background model is developed based on the PAF method. The surface background is estimated to be $0.09 \pm 0.06$ events for Run0 (0.54 tonne$\cdot$year) and $0.17 \pm 0.11$ events for Run1 (1.00 tonne$\cdot$year).

Explore related subjects

Keep this discovery

BibTeXRIS

Zhicheng Qian, Linhui Gu, Chen Cheng, Zihao Bo, Wei Chen, Xun Chen, Yunhua Chen, Zhaokan Cheng, Xiangyi Cui, Yingjie Fan, Deqing Fang, Zhixing Gao, Lisheng Geng, Karl Giboni, Xunan Guo, Xuyuan Guo, Zichao Guo, Chencheng Han, Ke Han, Changda He, Jinrong He, Di Huang, Houqi Huang, Junting Huang, Ruquan Hou, Yu Hou, Xiangdong Ji, Xiangpan Ji, Yonglin Ju, Chenxiang Li, Jiafu Li, Mingchuan Li, Shuaijie Li, Tao Li, Zhiyuan Li, Qing Lin, Jianglai Liu, Congcong Lu, Xiaoying Lu, Lingyin Luo, Yunyang Luo, Wenbo Ma, Yugang Ma, Yajun Mao, Yue Meng, Xuyang Ning, Binyu Pang, Ningchun Qi, Xiangxiang Ren, Dong Shan, Xiaofeng Shang, Xiyuan Shao, Guofang Shen, Manbin Shen, Wenliang Sun, Yi Tao, Anqing Wang, Guanbo Wang, Hao Wang, Jiamin Wang, Lei Wang, Meng Wang, Qiuhong Wang, Shaobo Wang, Siguang Wang, Wei Wang, Xiuli Wang, Xu Wang, Zhou Wang, Yuehuan Wei, Weihao Wu, Yuan Wu, Mengjiao Xiao, Xiang Xiao, Kaizhi Xiong, Yifan Xu, Shunyu Yao, Binbin Yan, Xiyu Yan, Yong Yang, Peihua Ye, Chunxu Yu, Ying Yuan, Zhe Yuan, Youhui Yun, Xinning Zeng, Minzhen Zhang, Peng Zhang, Shibo Zhang, Shu Zhang, Tao Zhang, Wei Zhang, Yang Zhang, Yingxin Zhang, Yuanyuan Zhang, Li Zhao, Jifang Zhou, Jiaxu Zhou, Jiayi Zhou, Ning Zhou. 2025-02-11. Position reconstruction and surface background model for the PandaX-4T detector. https://doi.org/10.1016/j.nima.2025.170548

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det