Publications and source records attributed to Réjean Fontaine.

7 recordsLinked to original sources

Electric Field Propagation with Spinal Cord Stimulation

Spinal cord stimulation is routinely used for the treatment of chronic pain, and is increasingly being investigated for the restoration of movement after paralysis. However, most of our current knowledge on epidural spinal cord stimulation relies on empirical approaches and semi-hybrid models. Hence, optimizing this therapy requires a better theoretical understanding of how stimulation affects the target neural structures. Using the physical properties of tissues combined with an electromagnetic, dielectric, and metallic description of them, we derived the electric field transmission coefficient through a given number of layers of tissue in the spinal cord. We then used this model to calculate the transmission of electric field energy in target neural tissues such as grey or white matter for different pulse width. Simulations suggest that the propagation through the tissues of the spinal cord of an epidurally applied electric field has a complex relationship with the field pulse width. In addition the electric field energy is absorbed at the junction between dura matter and cerebrospinal fluid, and within the cerebrospinal fluid as induced current. These currents hit the different bodies floating within the cerebrospinal fluid, and/or dorsal horn in a very localized region of the spinal cord. The proposed models allow theoretical calculation of the transmission factor for different numbers of layers of tissue within the spinal canal, and for different electric field pulse widths. This eases the prediction of the expected energy reaching each layer of the spinal cord for different tissues, parameters, and electrode configurations, simplifying the optimization of spinal cord stimulation treatment.

physics.bio-ph↗

Learning to See via Epiretinal Implant Stimulation in silico with Model-Based Deep Reinforcement Learning

Objective: Diseases such as age-related macular degeneration and retinitis pigmentosa cause the degradation of the photoreceptor layer. One approach to restore vision is to electrically stimulate the surviving retinal ganglion cells with a microelectrode array such as epiretinal implants. Epiretinal implants are known to generate visible anisotropic shapes elongated along the axon fascicles of neighboring retinal ganglion cells. Recent work has demonstrated that to obtain isotropic pixel-like shapes, it is possible to map axon fascicles and avoid stimulating them by inactivating electrodes or lowering stimulation current levels. Avoiding axon fascicle stimulation aims to remove brushstroke-like shapes in favor of a more reduced set of pixel-like shapes. Approach: In this study, we propose the use of isotropic and anisotropic shapes to render intelligible images on the retina of a virtual patient in a reinforcement learning environment named rlretina. The environment formalizes the task as using brushstrokes in a stroke-based rendering task. Main Results: We train a deep reinforcement learning agent that learns to assemble isotropic and anisotropic shapes to form an image. We investigate which error-based or perception-based metrics is adequate to reward the agent. The agent is trained in a model-based data generation fashion using the psychophysically validated axon map model to render images as perceived by different virtual patients. We show that the agent can generate more intelligible images compared to the naive method in different virtual patients. Significance: This work shares a new way to address epiretinal stimulation that constitutes a first step towards improving visual acuity in artificially-restored vision using anisotropic phosphenes.

cs.LG↗

Scalable 49-Channel Neural Recorder with an Event-Driven Ramp ADC and PCA Compression in 28 nm CMOS

Neural interfaces advance neuroscience research and therapeutic innovations by accurately measuring neuronal activity. However, recording raw data from numerous neurons results in substantial amount of data and poses challenges for wireless transmission. While conventional neural recorders consume energy to digitize and process the full neural signal, only a fraction of this data carries essential spiking information. Leveraging on this signal sparsity, this paper introduces a neural recording integrated circuit in TSMC 28nm CMOS. It features an event-driven ramp analog-to-digital converter, and a spike compression module based on principal component analysis. The circuit consists of 49 channels, each occupying an on-chip area of 50 $\times$ 60 $μ$m$^2$. The circuit measures 1370 $\times$ 1370 $μ$m$^2$ and consumes 534 $μ$W. Compression testing on a synthetic dataset demonstrated an 8.8-fold reduction compared to raw spikes and a 328-fold reduction relative to the raw signal. This compression approach maintained a spike sorting accuracy of 74.9%, compared to the 79.5% accuracy obtained with the raw signal. The paper details the architecture and performance outcomes of the neural recording circuit and its compression module.

eess.SY↗

Laser driven miniature diamond implant for wireless retinal prostheses

The design and benchtop operation of a wireless miniature epiretinal stimulator implant is reported. The implant is optically powered and controlled using safe illumination at near-infrared wavelengths. An application-specific integrated circuit (ASIC) hosting a digital control unit is used to control the implant's electrodes. The ASIC is powered using an advanced photovoltaic (PV) cell and programmed using a single photodiode. Diamond packaging technology is utilized to achieve high-density integration of the implant optoelectronic circuitry, as well as individual connections between a stimulator chip and 256 electrodes, within a 4.6 mm x 3.7 mm x 0.9 mm implant package. An ultrahigh efficiency PV cell with a monochromatic power conversion efficiency of 55% is used to power the implant. On-board photodetection circuity with a bandwidth of 3.7 MHz is used for forward data telemetry of stimulation parameters. In comparison to implants which utilize inductively coupled coils, laser power delivery enables a high degree of miniaturization and lower surgical complexity. The device presented combines the benefits of implant miniaturization and a flexible stimulation strategy provided by a dedicated stimulator chip. This development provides a route to fully wireless miniaturized minimally invasive implants with sophisticated functionalities.

eess.SP↗

Time-of-Flight X-ray Measurements for Computed Tomography

Time-of-flight (ToF) measurements is a possible alternative to anti-scatter grids in computed tomography (CT). Simulations have shown a possible 75% reduction in the detrimental scattering contribution with a 100 ps FWHM timing resolution. A test bench comprising a pulsed X-ray source and a time-correlated detector has been designed to demonstrate the feasibility of time-of-flight measurements of X-rays using readout electronics inherited from a ToF-positron emission tomography project. A 86 ps FWHM coincidence time resolution have been achieved with 511 keV annihilation gamma-rays and a 155 ps FWHM timing jitter with a 120 kVp pulsed X-rays source.

physics.med-ph↗

Feasibility Assessment of an Optically Powered Digital Retinal Prosthesis Architecture for Retinal Ganglion Cell Stimulation

Clinical trials previously demonstrated the notable capacity to elicit visual percepts in blind patients affected with retinal diseases by electrically stimulating the remaining neurons on the retina. However, these implants restored very limited visual acuity and required transcutaneous cables traversing the eyeball, leading to reduced reliability and complex surgery with high postoperative infection risks. To overcome the limitations imposed by cables, a retinal implant architecture in which near-infrared illumination carries both power and data through the pupil to a digital stimulation controller is presented. A high efficiency multi-junction photovoltaic cell transduces the optical power to a CMOS stimulator capable of delivering flexible interleaved sequential stimulation through a diamond microelectrode array. To demonstrate the capacity to elicit a neural response with this approach while complying with the optical irradiance limit at the pupil, fluorescence imaging with a calcium indicator is used on a degenerate rat retina. The power delivered by the laser at the permissible irradiance of 4 mW/mm2 at 850 nm is shown to be sufficient to both power the stimulator ASIC and elicit a response in retinal ganglion cells (RGCs), with the ability to generate of up to 35 000 pulses per second at the average stimulation threshold. This confirms the feasibility of generating a response in RGCs with an infrared-powered digital architecture capable of delivering complex sequential stimulation patterns at high repetition rates, albeit with some limitations.

q-bio.NC↗

Automatic Channel Fault Detection and Diagnosis System for a Small Animal APD-Based Digital PET Scanner

Fault detection and diagnosis is critical to many applications in order to ensure proper operation and performance over time. Positron emission tomography (PET) systems that require regular calibrations by qualified scanner operators are good candidates for such continuous improvements. Furthermore, for scanners employing one-to-one coupling of crystals to photodetectors to achieve enhanced spatial resolution and contrast, the calibration task is even more daunting because of the large number of independent channels involved. To cope with the additional complexity of the calibration and quality control procedures of these scanners, an intelligent system (IS) was designed to perform fault detection and diagnosis (FDD) of malfunctioning channels. The IS can be broken down into four hierarchical modules: parameter extraction, channel fault detection, fault prioritization and diagnosis. Of these modules, the first two have previously been reported and this paper focuses on fault prioritization and diagnosis. The purpose of the fault prioritization module is to help the operator to zero in on the faults that need immediate attention. The fault diagnosis module will then identify the causes of the malfunction and propose an explanation of the reasons that lead to the diagnosis. The FDD system was implemented on a LabPET avalanche photodiode (APD)-based digital PET scanner. Experiments demonstrated a FDD Sensitivity of 99.3 % (with a 95% confidence interval (CI) of: [98.7, 99.9]) for major faults. Globally, the Balanced Accuracy of the diagnosis for varying fault severities is 92 %. This suggests the IS can greatly benefit the operators in their maintenance task.

cs.AI↗