SearcharxivSearch

arXiv subjects

Rüdiger Quay

Publications and source records attributed to Rüdiger Quay.

6 recordsLinked to original sources

Characterizing the nitrogen-vacancy center singlet transition and its phonon sideband for absorption-based room-temperature magnetometry

Magnetometry with nitrogen-vacancy (NV) centers in diamond has shown great promise in recent years. In particular, absorption-based magnetometry techniques, employing a cavity to enhance the absorption length, can improve the contrast and sensitivity compared to conventional techniques based on reading out the NV$^-$ triplet fluorescence. The absorption techniques rely on magnetic-field-dependent absorption at the NV$^-$ singlet zero phonon line at 1042$\,$nm and its phonon sideband. In a cavity-enhanced spectroscopy approach, we study pump-laser- and microwave-induced cavity signal changes at room temperature over a spectral range of 680-1050$\,$nm. Through normalization, we eliminate the cavity-enhancement effect and provide quasi-single-pass values for the absorption and optically detected magnetic resonance (ODMR) contrast. The highest contrast is found at 1042$\,$nm, but multiple points of high contrast are found at the peaks of the phonon sideband. Additionally, cavity-enhanced ODMR contrasts in the range of 50-80$\,\%$ are presented. We further measure the broadband singlet absorption cross section at room temperature with a novel method through microwave-induced signal changes. This method is insensitive to pump-laser-induced signal changes by other defects and quantifies the room-temperature absorption strength of the singlet transition and its entire phonon sideband. We determine the absorption cross section at 1042$\,$nm to be $σ^{\,\bigstar}_{1042}=(0.89\pm0.14)\cdot 10^{-21}\,\text{m}^2$ or $σ^{\,\blacktriangle}_{1042}=(2.9\pm0.5)\cdot 10^{-21}\,\text{m}^2$. depending on the employed 532$\,$nm NV$^-$ absorption cross section.

quant-ph

TARE: Block Encoding Linear Combinations of Pauli Strings Without Ancilla State Preparation

Quantum algorithms based on Quantum Signal Processing (QSP) offer the potential for speedups across a broad range of applications, with block encodings serving as the central input model. In this framework, non-unitary matrices are embedded into larger unitary operators, and the cost of constructing these encodings often dominates the overall gate complexity. In this work, we introduce Tag-and-Restore Encoding (TARE), a block-encoding method for linear combinations of Pauli strings. In this method coefficient magnitudes are absorbed into a unitary built from a set of mutually anti-commuting Pauli strings acting on the system register. These Pauli strings are then mapped to the target Pauli strings through appropriate transformations, yielding a block encoding of the target operator. The ancilla register size scales logarithmically with the number of Pauli strings and can be extended to larger registers providing a width/depth tradeoff. We evaluate TARE through numerical simulations of the transverse-field Ising model, the Jordan-Wigner image of a fermionic star Hamiltonian, and random Pauli-string operators. Compared with standard Linear Combination of Unitaries (LCU), TARE substantially reduces the T-gate count while improving circuit depth in several cases. These results suggest that TARE can provide resource-efficient block encodings for a wide range of relevant systems.

quant-ph

Laser-enhanced quantum sensing boosts sensitivity and dynamic range

Magnetometers based on nitrogen-vacancy (NV) centers in diamond have emerged as the most important solid-state quantum sensors. However, ensembles are limited in optical contrast to typically a few percent and high-sensitivity variants usually possess only a few $\mathrm{\upmu}$T dynamic range. Here, we demonstrate a laser threshold magnetometry-based NV system that avoids these limitations. By integrating the NV centers into a laser cavity and showing magnetic-field-dependent shifts of the laser threshold, we observe 100\,\% optical contrast, i.\,e., we are able to entirely switch off the laser system with the NV centers magnetic resonance. At the same time we achieve strong output signals up to 50\,mW. The system exhibits a photon-shot-noise-limited (PSNL) sensitivity of $<$400\,fT/$\sqrt{\textrm{Hz}}$ for all vector components, which we demonstrate to improve super-linearly with contrast. The ratio of the sensing-relevant parameters PSNL sensitivity and dynamic range, that can be traded at the cost of each other, marks an improvement factor of up to 590 over typical fluorescence-based readout and vapor cell sensors while also adding vector magnetometry capabilities. Such performance improvements provide a perspective for a highly sensitive magnetometer, which could be operated outside a magnetically-shielded room. This could bring a new generation of sensors for applications including magnetoencephalography, magnetic navigation, and magnetic anomaly detection.

quant-ph

Two-media laser threshold magnetometry: A magnetic-field-dependent laser threshold

Nitrogen-vacancy (NV) centers in diamond are a promising platform for high-precision magnetometry. In contrast to the use of spontaneous emission in a number of NV-magnetometers, laser threshold magnetometry (LTM) exploits stimulated emission of NV centers by placing an NV-doped diamond inside an optical cavity. The NV laser system is predicted to reach a high magnetic-field-dependent contrast and coherent signal strength, leading to an improved magnetic field sensitivity combined with a high linearity. Here, we consider a two-media setup where the cavity additionally includes a vertical external cavity surface emitting laser. This optically active material compensates cavity losses at \SI{750}{nm} while still allowing for magnetic-field-dependent effects from the NV-diamond. We demonstrate a magnetic-field-dependent laser threshold and investigate the effects of pump laser induced absorption of the diamond. The experimental data is supported by an analytical simulation based on a rate model. Furthermore, we derive a generalized formula to compute the shot-noise-limited magnetic field sensitivity in the regime of high contrast yielding 49.07(33) pT/$\sqrt{\text{Hz}}$ for the present setup. Simulations with an optimized NV-diamond suggest that values down to 4.9 ft/$\sqrt{\text{Hz}}$ are possible.

physics.optics

High-contrast absorption magnetometry in the visible to near-infrared range with nitrogen-vacancy ensembles

Magnetometry with nitrogen-vacancy (NV) centers has so far been measured via emission of light from NV centers or via absorption at the singlet transition at 1042 nm. Here, we demonstrate a phenomenon of broadband optical absorption by the NV centers starting in the emission wavelength and reaching up to 1000 nm. The measurements are enabled by a high-finesse cavity, which is used for room temperature continuous wave pump-probe experiments. The red to infrared probe beam shows the typical optically detected magnetic resonance (ODMR) signal of the NV spin with contrasts up to 42 %. This broadband optical absorption is not yet reported in terms of NV magnetometry. We argue that the lower level of the absorbing transition could be the energetically lower NV singlet state, based on the increased optical absorption for a resonant microwave field and the spectral behavior. Investigations of the photon-shot-noise-limited sensitivity show improvements with increasing probe wavelength, reaching an optimum of 7.5 pT/$\sqrt{\mathrm{Hz}}$. The results show significantly improved ODMR contrast compared to emission-based magnetometry. This opens a new detection wavelength regime with coherent laser signal detection for high-sensitivity NV magnetometry.

physics.app-ph

Continuous-wave nitrogen-vacancy diamond laser system assisted by a red diode laser

Diamond has long been identified as a potential host material for laser applications. This potential arises due to its exceptional thermal properties, ultra-wide bandgap, and color centers which promise gain across the visible spectrum. More recently, coherent laser methods offer new approaches to magnetometry. However, diamond fabrication is difficult in comparison to other crystalline matrices, and many optical loss channels are not yet understood. Here, we demonstrate the first continuous-wave nitrogen-vacancy (NV) color center laser system. To achieve this, we constructed a laser cavity with both, an NV-diamond medium and an intra-cavity anti-reflection coated diode laser. This dual-medium approach compensates intrinsic losses of the cavity by providing a fixed additional gain below threshold of the diode laser. We observe the first clear continuous-wave laser threshold in the output of the laser system as well as linewidth narrowing with increasing green pump power on the NV centers. Our results are a major development towards coherent approaches to magnetometry.

quant-ph