Searcharxiv⌕ Search

arXiv subjects

R. E. Mischke

Publications and source records attributed to R. E. Mischke.

24 records · Page 2Linked to original sources

TWIST: Precision Measurement of the Muon Decay Parameters

The TWIST experiment has made a precision measurement of three of the decay parameters in muon decay. The newest results are rho = 0.75014 +-0.00017(stat) +-0.00044(sys) +-0.00011(eta) and delta = 0.75067 +-0.00030(stat) +-0.00067(sys). Together with previously published results, improved constraints on possible extensions of the electroweak Standard Model are derived.

hep-ex↗

A Precision Measurement of the Muon Decay Parameters $ρ$ and $δ$

The TWIST collaboration has performed new measurements of two of the parameters that describe muon decay: $ρ$, which governs the shape of the overall momentum spectrum, and $δ$, which governs the momentum dependence of the parity-violating decay asymmetry. This analysis gives the results $ρ=0.75014\pm 0.00017(\text{stat})\pm 0.00044(\text{syst})\pm 0.00011(η)$, where the last uncertainty arises from the correlation between $ρ$ and the decay parameter $η$, and $δ= 0.75067\pm 0.00030(\text{stat})\pm 0.00067(\text{syst})$. These are consistent with the value of 3/4 given for both parameters in the Standard Model of particle physics, and are a factor of two more precise than the measurements previously published by TWIST. A new global analysis of all available muon decay data incorporating these results is presented. Improved lower and upper limits on the decay parameter $P_μ^πξ$ of $0.99524 < P_μ^πξ\leq ξ< 1.00091$ at 90% confidence are determined, where $P_μ^π$ is the polarization of the muon when it is created during pion decay, and $ξ$ governs the muon decay asymmetry. These results set new model-independent constraints on the possible weak interactions of right-handed particles. Specific implications for left-right symmetric models are discussed.

hep-ex↗

Measurement of P_{mu}xi in Polarized Muon Decay

The quantity P_{mu}^{pi}xi, where xi is one of the muon decay parameters and $P_μ^π$ is the degree of muon polarization in pion decay, has been measured. The value P_{mu}^{pi}xi = 1.0003 +- 0.0006 stat. +- 0.0038 syst. was obtained. This result agrees with previous measurements but is over a factor of two more precise. It also agrees with the Standard Model prediction for P_{mu}^{pi}xi and thus leads to restrictions on left-right symmetric models.

hep-ex↗

High Voltage Test Apparatus for a Neutron EDM Experiment and Lower Limit on the Dielectric Strength of Liquid Helium at Large Volumes

A new search for a permanent electric dipole moment (EDM) of the neutron is underway using ultracold neutrons produced and held in a bath of superfluid helium. Attaining the target sensitivity requires maintaining an electric field of several tens of kilovolts per centimeter across the experimental cell, which is nominally 7.5 cm wide and will contain about 4 liters of superfluid. The electrical properties of liquid helium are expected to be sufficient to meet the design goals, but little is known about these properties for volumes and electrode spacings appropriate to the EDM experiment. Furthermore, direct application of the necessary voltages from an external source to the experimental test cell is impractical. An apparatus to amplify voltages in the liquid helium environment and to test the electrical properties of the liquid for large volumes and electrode spacings has been constructed. The device consists of a large-area parallel plate capacitor immersed in a 200 liter liquid helium dewar. Preliminary results show the breakdown strength of normal state liquid helium is at least 90 kV/cm at these volumes, at the helium vapor pressure corresponding to 4.38 K. These fields hold for more than 11 hours with leakage currents less than 170 pA (about 20% of the maximum tolerable in the EDM experiment). The system is also found to be robust against anticipated radiation backgrounds. Preliminary results for superfluid show that fields of at least 30 kV/cm can be sustained at the volumes required for the EDM experiment, about 60% of the design goal. These results are likely limited by the low pressure that must be maintained above the superfluid bath.

physics.ins-det↗

Measurement of the Muon Decay Parameter delta

The muon decay parameter delta has been measured by the TWIST collaboration. We find delta = 0.74964 +- 0.00066(stat.) +- 0.00112(syst.), consistent with the Standard Model value of 3/4. This result implies that the product Pmuxi of the muon polarization in pion decay, Pmu, and the muon decay parameter xi falls within the 90% confidence interval 0.9960 < Pmuxi < xi < 1.0040. It also has implications for left-right-symmetric and other extensions of the Standard Model.

hep-ex↗