SearcharxivSearch

arXiv subjects

R. Guenette

Publications and source records attributed to R. Guenette.

At least 19 recordsLinked to original sources

Detection of scintillation light in noble gases with wavelength-shifting optical fibers

Wavelength-shifting (WLS) techniques enable particle detectors based on noble gases, whose scintillation light is predominantly emitted in the vacuum-ultraviolet. We investigate WLS fibers coated with tetraphenyl butadiene (TPB) for scintillation light detection in gaseous xenon and argon at pressures up to 8.5 bar, motivated by future high-pressure xenon time-projection chambers of the NEXT program. Two detector configurations are studied: an elongated high-pressure vessel with four PTFE panels equipped with WLS fibers read by temperature-stabilized SiPMs, and a compact box-shaped detector operated at 1 bar Xe with WLS fibers read out by PMTs. Both operate with continuous gas purification. The detector response is characterized using cosmic muons and alpha particles from a $^{241}$Am source. With the SiPM setup, we measure a light collection efficiency (LCE) of ${1.18 \pm 0.01~\mathrm{(sta.)}~^{+0.07}_{-0.09}~\mathrm{(sys.)}~\%}$ for xenon and ${1.07 \pm 0.01~\mathrm{(sta.)}~^{+0.06}_{-0.08}~\mathrm{(sys.)}~\%}$ for argon. With PMT readout, we measure a LCE of ${0.45 \pm 0.01~\mathrm{(sta.)} \pm 0.05~\mathrm{(sys.)}~\%}$ in xenon, in agreement with the SiPM result once photon detection efficiency is accounted for. Average scintillation waveforms in xenon and argon are studied to assess the time structure of the emitted light. Cosmic-muon measurements yield a mean energy required to produce a scintillation photon $45\pm7~\mathrm{(sta.)}~^{+4}_{-5}~\mathrm{(sys.)}~\mathrm{eV}$ at 1.5 bar, in agreement with the literature. The results demonstrate that TPB-coated WLS fiber systems can reliably detect scintillation light in high-pressure gaseous noble detectors, with a LCE representing an upper limit for realistic large-scale TPCs, where additional photon losses from materials and fiber attenuation are expected.

physics.ins-det

Probing Nuclear Effects with Transverse Kinematic Imbalance in Muon-neutrino Induced Charged-Current $\pi^0$ Production on Argon with the MicroBooNE Detector

Neutrino-nucleus cross-section measurements are needed to improve interaction modeling and to enable precision neutrino oscillation measurements in upcoming experiments such as the Deep Underground Neutrino Experiment (DUNE), Hyper-Kamiokande, and the Short-Baseline Neutrino program. Baryon-resonance neutrino interactions constitute a dominant contribution near the peak of the DUNE neutrino energy spectrum. We present the first measurement of muon neutrino charged-current resonance-like interactions on argon using transverse kinematic imbalance variables with the MicroBooNE detector. These observables are highly sensitive to the modeling of final-state interactions. This measurement probes kinematic imbalances using the reconstructed momenta of the muon, leading proton, and neutral pion. A comprehensive characterization of the $\pi^0$-proton final state is presented; however, none of the models considered are able to simultaneously reproduce all measured observables.

hep-ex

First Measurement of Sub-GeV $\nu_{\mu}$ Charged-Current Coherent Pion Production on Argon in MicroBooNE

We report a measurement of the charged-current coherent pion production cross section on argon using the MicroBooNE liquid argon time projection chamber exposed to the Booster Neutrino Beam at Fermilab. The measurement uses the MicroBooNE data set corresponding to $1.26 \times 10^{21}$ protons on target with a mean neutrino energy of $0.8$~GeV. The flux-averaged cross section is measured to be $(9.1 \pm 1.2_{\text{stat}} \pm 1.2_\text{syst}) \times 10^{-40}\,\text{cm}^2/\text{Ar}$. This result represents the first measurement of charged-current coherent pion production on argon at sub-GeV neutrino energies. Due to its clean two-body kinematics, where the neutrino interacts coherently with the entire nucleus producing a forward muon and pion with no nuclear breakup, this process provides a useful tool for constraining neutrino flux uncertainties in current and future oscillation experiments such as DUNE.

hep-ex

Characterizing the energy resolution of the MicroBooNE LArTPC at the MeV scale using monoenergetic features of $^{208}$Tl decays

A detailed understanding of the capabilities and fidelity of low-energy reconstruction is crucial for taking advantage of MeV-scale neutrino physics opportunities in liquid argon time projection chambers (LArTPCs). This study presents a measurement of the resolution of reconstructed energy in the MicroBooNE LArTPC at $\approx 1.5$ MeV. The characterization is performed using monoenergetic signals generated by $2.614$ MeV $\gamma$-rays from $^{208}$Tl decays undergoing pair production in the detector. The resolution is found to be ($7.52 \pm 0.78 \text{(stat)} \pm 0.92 \text{(syst)}$)%. This value is consistent with the MicroBooNE simulation prediction of ($9.70 \pm 0.65 \text{(stat)}$)% at the $1.6 \sigma$ level. This study represents the first ever measurement of LArTPC energy resolution at the MeV scale and provides a pathway for monoenergetic energy calibrations in future experiments using LArTPC detectors.

physics.ins-det

Improved muon energy estimation using a detailed model of multiple Coulomb scattering in the MicroBooNE LArTPC

We present an improved technique for estimating a muon's energy by measuring the deflections along its path inside the MicroBooNE detector from multiple Coulomb scattering (MCS). This approach implements several innovations that better capture detector non-idealizations compared to previous MCS-based muon energy estimators. As a result, it achieves improved resolution, reduced bias, and better data-model agreement. Using model simulation, for fully contained events the estimated bias is within 1% and the estimated resolution varies from 4.3% to 10% as muon energy increases from 0.1 GeV to 2 GeV. For events with particles exiting the detector volume, at least a meter of reconstructed muon track, and a muon energy below 2 GeV, the estimated bias is less than 2% and the estimated resolution varies from 7% to 17% over muon energy. These demonstrate significant improvements over the performance of previous work using an MCS-based energy estimator at MicroBooNE, which achieves twice as large a resolution as well as a bias of 20% over the same energy region. Data-model goodness-of-fit studies are used to validate the estimator's performance on data, showing good agreement within model uncertainties.

hep-ex

Radon-induced backgrounds in the NEXT-100 experiment

The NEXT-100 detector at the LSC aims at the first competitive search for the \bbnonu decay using a high-pressure \Xe{136} electroluminescent time projection chamber. The first low-background run of NEXT-100 at 3.95 bar has been devoted to the measurement of the radon-induced backgrounds impacting this search. The contributions from both the internal and external airborne radon have been evaluated. The internal \Rn{222} activity is found to be (0.95$\pm$0.04(stat)$\pm$0.09(sys)) Bq/m$^3$, while no traces of \Rn{220} have been observed. Most of the \Rn{222} progeny plate-out on the surface of the cathode of the detector, leading to a rate of Rn-induced \Bi{214} of (0.97$\pm$0.05(stat)$\pm$0.10(sys)) Hz for visible energies above 400 keV. The corresponding background index in the \bbnonu region of interest is evaluated as (7.3$\pm$1.5(stat)$\pm$0.8(sys))$\times10^{-4}$ counts/(keV$\cdot$kg$\cdot$yr) after selection of the fully contained events. This background index is reduced to $\sim$4$\times10^{-5}$ counts/(keV$\cdot$kg$\cdot$yr) by applying a topological selection requiring only one double-electron-like track in the events. This value is one order of magnitude below the total radiogenic background expectation in NEXT-100. By analyzing the correlation of the airborne radon activity and the measured rate of events in NEXT-100, it is concluded that the detector operates in a virtually radon-free environment thanks to the radon abatement system of the LSC.

hep-ex

Electroluminescence Yield Measurements in Xenon Gas with the NEXT-DEMO++ Detector

The NEXT-DEMO++ detector, a high-pressure xenon gas time projection chamber serving as a prototype for the NEXT-100 experiment, was used to measure the electroluminescence (EL) yield as a function of reduced electric field ($E/p$) across pressures from 2.0 to 9.4 bar, utilizing the 41.5 keV de-excitation peak of $^{83m}$Kr. These measurements were made to examine the pressure dependence of the slope of the reduced EL yield $Y/p$, which has shown inconsistencies in the literature. The reduced yield was fitted with a linear model, revealing a modest ($\sim$5%) change in slope, beginning around 5 bar and increasing with pressure up to 9.4 bar.

physics.ins-det

Scintillation light calibrations, systematic uncertainties, and triggering efficiency in the MicroBooNE detector

Scintillation light, produced alongside ionisation charge from particle interactions, plays a critical role in liquid argon time projection chamber (LArTPC) detectors. A detailed understanding of its production and detection mechanisms is essential for robust calibration, systematic uncertainty evaluation, and physics analysis. This article describes the MicroBooNE light simulation, light-based triggering schemes, photomultiplier tube gain calibration, light response stability, and light-based systematic uncertainties over the course of five years of data collection. In addition, we present a measurement of scintillation light triggering efficiency, focusing on the lowest-light regime relevant to rare-event searches and low-energy neutrino interactions. Finally, we discuss two notable observations in MicroBooNE's data, both reported here for the first time: an approximately 50% decline in MicroBooNE's light yield over time, concentrated in the first two years of running; and a higher than expected O(200 kHz) rate of single photoelectron noise. The results presented provide an important benchmark of long-term light detection performance in LArTPC neutrino detectors.

physics.ins-det

Measurements of the electron neutrino-argon differential cross section without pions in the final state in MicroBooNE

We present a new measurement of the electron neutrino charged current cross section on argon without pions in the final state. This measurement uses the full MicroBooNE booster neutrino beam dataset of $1.3\times 10^{21}$ protons on target collected at Fermi National Accelerator Laboratory. Events are considered both with and without protons above the kinetic energy visibility threshold. Differential cross sections are extracted in proton and electron kinematics, including energy and angle relative to the neutrino beam direction. The relationship between the hadronic and leptonic systems is explored through the angle between the proton and electron directions. The resulting cross sections are compared to a variety of available generator predictions using different models of neutrino interactions. We find good agreement with most models in lepton kinematics and some discrepancies in the hadronic system modeling, particularly in proton angle.

hep-ex

Demonstration and performance of an online data selection algorithm for liquid argon time projection chambers using MicroBooNE

The MicroBooNE detector is a liquid argon time projection chamber (LArTPC) that produces three-dimensional images of particle interactions using ionization charge collected by anode wire plane arrays and scintillation light collected by a light detection system. In addition to testing long-standing experimental neutrino anomalies and performing measurements of neutrino interactions with argon nuclei using the Fermilab Booster Neutrino Beam, MicroBooNE aims to develop methodologies for rare beyond the Standard Model and off-beam physics searches. Looking ahead to the upcoming Deep Underground Neutrino Experiment (DUNE), with MicroBooNE serving as a valuable testbed, achieving high sensitivity and livetime for off-beam physics while satisfying data processing and storage constraints will require data-driven, intelligent, and online or real-time data selection techniques. These techniques are essential for reducing data rates and preserving rare signals with high accuracy. In this paper, we describe a fast data selection algorithm suitable for online execution to identify electrons from stopping cosmic ray muons in the MicroBooNE detector utilizing ionization charge information, and present its performance. This represents the first demonstration of online data selection in a LArTPC using real data and charge information exclusively and provides an important proof-of-principle for applying such techniques to other LArTPC experiments such as the Short-Baseline Near Detector and DUNE.

hep-ex

Search for Light Sterile Neutrinos With Two Neutrino Beams at MicroBooNE

The existence of three distinct neutrino flavours, $\nu_{e}$, $\nu_{\mu}$, and $\nu_{\tau}$, is a central tenet of the Standard Model of particle physics. Quantum-mechanical interference can allow a neutrino of one initial flavour to be detected some time later as a different flavour, a process called neutrino oscillation. Several anomalous observations inconsistent with this three-flavour picture have motivated the hypothesis that an additional neutrino state exists which does not interact directly with matter, termed a "sterile" neutrino, $\nu_s$. This includes anomalous observations from the LSND and MiniBooNE experiments, consistent with $\nu_{\mu}\rightarrow\nu_{e}$ transitions at a distance inconsistent with the three-neutrino picture. Here, we use data obtained from the MicroBooNE liquid-argon time projection chamber in two accelerator neutrino beams to exclude the single light sterile neutrino interpretation of the LSND and MiniBooNE anomalies at the 95\% confidence level (CL). Additionally, we rule out a significant portion of the parameter space that could explain the gallium anomaly. This is the first measurement to use two accelerator neutrino beams to break a degeneracy between $\nu_{e}$ appearance and disappearance that would otherwise weaken the sensitivity to the sterile neutrino hypothesis. We find no evidence for either $\nu_{\mu}\rightarrow\nu_{e}$ flavour transitions or $\nu_{e}$ disappearance that would indicate non-standard flavour oscillations. Our results show that previous anomalous observations consistent with $\nu_{\mu}\rightarrow\nu_{e}$ transitions cannot be explained by introducing a single sterile neutrino state.

hep-ex

Measurements of differential charged-current cross sections on argon for electron neutrinos with final-state protons in MicroBooNE

This work presents single-differential electron-neutrino charged-current cross sections on argon measured using the MicroBooNE detector at the Fermi National Accelerator Laboratory. The analysis uses data recorded when the Neutrinos at the Main Injector beam was operating in both neutrino and antineutrino modes, with exposures of $2 \times 10^{20}$ and $5 \times 10^{20}$ protons on target, respectively. A selection algorithm targeting electron-neutrino charged-current interactions with at least one proton, one electron, and no pions in the final topology is used to measure differential cross sections as a function of outgoing electron energy, total visible energy, and opening angle between the electron and the most energetic proton. The interaction rate as a function of proton multiplicity is also reported. The total cross section is measured as [4.1 $\pm$ 0.3 (stat.) $\pm$ 1.1 (syst.)]$ $$\times 10^{-39} \mathrm{cm}^{2}/ \mathrm{nucleon}$. The unfolded cross-section measurements are compared to predictions from neutrino event generators commonly employed in the field. Good agreement is seen across all variables within uncertainties.

hep-ex

Demonstration of Sub-Percent Energy Resolution in the NEXT-100 Detector

NEXT-100 is a high-pressure xenon time projection chamber with electroluminescent amplification, designed to operate with up to approximately 70.5 kg at 13.5 bar. It is the most recent detector developed by the NEXT collaboration to search for the neutrinoless double-beta decay ($\beta\beta 0\nu$) of Xe-136. The NEXT gas TPC technology offers the best energy resolution near the Q-value of the decay ($Q_{\beta\beta}$ = 2458 keV) among xenon detectors, which is set by design to be <1% FWHM. We report here the high-energy calibration of the detector using a Th-228 source, demonstrating linear response and an energy resolution of $(0.90 \pm 0.02)$% FWHM at the Tl-208 photopeak (2615 keV). This performance extrapolates to a resolution at the double-beta decay end-point of $R(Q_{\beta\beta})$ = $(0.93 \pm 0.02)$% FWHM, confirming the detector's capability for precision energy measurement in the search for $\beta\beta 0\nu$.

physics.ins-det

First results of the NEXT-100 detector using $^{83m}$Kr decays

The NEXT collaboration is investigating the double beta decay of $^{136}$Xe using high-pressure gas electroluminescent time projection chambers, which provide excellent energy resolution together with a robust topological signature. Operating at the Laboratorio Subterr\'aneo de Canfranc (LSC) and building on the success of the NEXT-White detector, the NEXT-100 apparatus began commissioning in May 2024 and started operation with xenon at a pressure of 4 bar in October 2024. We report here the first results obtained with NEXT-100 using low-energy calibration data from $^{83m}$Kr decays, which allow mapping of the detector response in the active volume and monitoring of its stability over time. After homogenizing the light response, we achieve an energy resolution of 4.37% FWHM at 41.5 keV for $^{83m}$Kr point-like energy deposits contained in a radius of 425 mm. In a fiducial region representing the operating conditions of NEXT-100 at 10 bar we obtain an improved energy resolution of 4.16% FWHM. These results are in good agreement with that obtained in NEXT-White, and an $E^{-1/2}$ extrapolation to $Q_{\beta\beta}$ yields an energy resolution close to 0.5% FWHM, well below the 1% FWHM design target.

hep-ex

Measurement of single charged pion production in charged-current $\nu_\mu$-Ar interactions with the MicroBooNE detector

We present flux-averaged charged-current $\nu_\mu$ cross-section measurements on argon for final states containing exactly one $\pi^\pm$ and no other hadrons except nucleons. The analysis uses data from the MicroBooNE experiment in the Booster Neutrino Beam, corresponding to $1.11 \times 10^{21}$ protons on target. Total and single-differential cross-section measurements are provided within a phase space restricted to muon momenta above 150 MeV, pion momenta above 100 MeV, and muon-pion opening angles smaller than 2.65 rad. Differential cross sections are reported with respect to the scattering angles of the muon and pion relative to the beam direction, their momenta, and their combined opening angle. The differential cross section with respect to muon momentum is based on a subset of selected events with the muon track fully contained in the detector, whereas the cross section with respect to pion momentum is based on a subset of selected events rich in pions that have not hadronically scattered on the argon before coming to rest. The latter has not been measured on argon before. The total cross section is measured as $(3.75~\pm~0.07~\textrm{(stat.)}~\pm~0.80~\textrm{(syst.)}) \times 10^{-38} \, \text{cm}^2/\text{Ar}$ at a mean energy of approximately 0.8 GeV. Comparisons of the measured cross sections with predictions from multiple neutrino-nucleus interaction generators show good overall agreement, except at very forward muon angles.

hep-ex

Opportunities and challenges to study solar neutrinos with a Q-Pix pixel readout

The study of solar neutrinos presents significant opportunities in astrophysics, nuclear physics, and particle physics. However, the low-energy nature of these neutrinos introduces considerable challenges to isolate them from background events, requiring detectors with low-energy threshold, high spatial and energy resolutions, and low data rate. We present the study of solar neutrinos with a kiloton-scale liquid argon detector located underground, instrumented with a pixel readout using the Q-Pix technology. We explore the potential of using volume fiducialization, directional topological information, light signal coincidence and pulse-shape discrimination to enhance solar neutrino sensitivity. We find that discriminating neutrino signals below 5 MeV is very difficult. However, we show that these methods are useful for the detection of solar neutrinos when external backgrounds are sufficiently understood and when the detector is built using low-background techniques. When building a workable background model for this study, we identify {\gamma} background from the cavern walls and from capture of {\alpha} particles in radon decay chains as both critical to solar neutrino sensitivity and significantly underconstrained by existing measurements. Finally, we highlight that the main advantage of the use of Q-Pix for solar neutrino studies lies in its ability to enable the continuous readout of all low-energy events with minimal data rates and manageable storage for further offline analyses.

hep-ex

Measurement of charged-current muon neutrino-argon interactions without pions in the final state using the MicroBooNE detector

We report a new measurement of flux-integrated differential cross sections for charged-current (CC) muon neutrino interactions with argon nuclei that produce no final-state pions ($\nu_\mu\mathrm{CC}0\pi$). These interactions are of particular importance as a topologically defined signal dominated by quasielasticlike interactions. This measurement was performed with the MicroBooNE liquid argon time projection chamber detector located at the Fermilab Booster Neutrino Beam and uses an exposure of $1.3\times10^{21}$ protons on target collected between 2015 and 2020. The results are presented in terms of single- and double-differential cross sections as a function of the final-state muon momentum and angle. The data are compared with widely used neutrino event generators. We find good agreement with the single-differential measurements, while only a subset of generators are also able to adequately describe the data in double-differential distributions. This work facilitates comparison with Cherenkov detector measurements, including those located at the Booster Neutrino Beam.

hep-ex

The NEXT-100 Detector

The NEXT collaboration is dedicated to the study of double beta decays of $^{136}$Xe using a high-pressure gas electroluminescent time projection chamber. This advanced technology combines exceptional energy resolution ($\leq 1\%$ FWHM at the $Q_{\beta\beta}$ value of the neutrinoless double beta decay) and powerful topological event discrimination. Building on the achievements of the NEXT-White detector, the NEXT-100 detector started taking data at the Laboratorio Subterr\'aneo de Canfranc (LSC) in May of 2024. Designed to operate with xenon gas at 13.5 bar, NEXT-100 consists of a time projection chamber where the energy and the spatial pattern of the ionising particles in the detector are precisely retrieved using two sensor planes (one with photo-multiplier tubes and the other with silicon photo-multipliers). The detector has been operating at stable conditions using argon and xenon gases at $\sim$4 bar and drift fields of 74 V/cm and 118 V/cm, respectively. Alpha decays from the $^{222}$Rn chain have been used to test and monitor the stability of the detector, showing a constant electron lifetime in the drift volume. In this paper, in addition to reporting the results of the commissioning run, we provide a detailed description of the NEXT-100 detector, describe its assembly, and present the current estimation of the radiopurity budget.

physics.ins-det