SearcharxivSearch

arXiv subjects

R. Mahapatra

Publications and source records attributed to R. Mahapatra.

At least 19 recordsLinked to original sources

Axion-Like Particle Search with a Hybrid Cherenkov-Scintillation Detector

This analysis presents the first proof-of-concept search for axion-like particles (ALPs) using a hybrid Cherenkov-scintillation detector at a beam-dump facility. The work is based on the Coherent CAPTAIN-Mills (CCM) experiment, a 10-ton liquid argon light collection detector located at Los Alamos National Laboratory. The CCM200 detector is instrumented with 200 photomultiplier tubes (PMTs), providing approximately 50% photocathode coverage. To enable optical discrimination, 80% of the PMTs are coated with a wavelength-shifting material while the remaining 20% are left uncoated. This configuration, combined with nanosecond-scale timing resolution, provides sensitivity to prompt Cherenkov radiation while maintaining efficient detection of liquid argon scintillation light [1, 2]. This analysis constructs four observables that exploit the Cherenkov emission and event topology expected from ALP-induced electromagnetic interactions. These observables are combined into a likelihood-ratio classifier that provides powerful rejection of steady-state backgrounds. No statistically significant excess above the expected background prediction is observed for $10^{-3}~\mathrm{MeV} < m_a < 10~\mathrm{MeV}$. Nevertheless, the improved background rejection enabled by hybrid Cherenkov-scintillation detection allows this analysis to surpass the sensitivity of the previous CCM120 search [3] despite less exposure and demonstrate the physics potential for hybrid Cherenkov-scintillation detectors.

hep-ex

Calibration and Performance of Germanium High Voltage Detectors for SuperCDMS SNOLAB

As SuperCDMS SNOLAB is getting ready to search for low mass dark matter particles, using cryogenic Ge and Si detectors, a set of six of the new SuperCDMS High Voltage (HV) detectors (four Ge and two Si) were tested in the Cryogenic Underground TEst facility (CUTE) at SNOLAB. This provided the first opportunity to gain experience with this new detector type and assess their performance thoroughly under low background conditions. Here we describe the SuperCDMS HV detector concept and discuss some of the newly developed analysis methods and approaches. Focusing on the Ge detectors, we investigate the detector performance under voltage bias (up to 90 V), exercise the low energy (keV to sub-keV range) calibration based on the electron capture peaks generated by the decay of $^{71}$Ge, assess the detector resolution, and demonstrate the unexpected (and encouraging) ability of these detectors to also measure high energy interactions in the hundreds of keV range with good resolution (better than 3% at 356 keV).

physics.ins-det

Exploring Low Energy Excess in MINER with sapphire detectors using Convolutional Variational Autoencoder (CVAE)

As cryogenic detectors push toward ever-lower energy thresholds, their sensitivity is increasingly constrained by a persistent low-energy background known as the low-energy excess (LEE). We report observation of LEE in the MINER experiment using a sapphire ($\mathrm{Al_2O_3}$) detector at energies around 200 eV, with the excess reproducibly reappearing after each non-operational warm-up period. To address this limiting background, we implement an unsupervised convolutional variational autoencoder (CVAE) framework that identifies anomalous events through a reconstruction-based anomaly score. For the first time in a pulse-shape driven analysis, we uncover a significant deviation in the rise-time of LEE events relative to Monte Carlo simulated ideal signals. Using this feature, we develop a discrimination pipeline based on rise-time selection. This method achieves up to 53\% rejection of LEE events, corresponding to an expected sensitivity improvement of nearly 10\% for MINER at HFIR. These findings are consistent with a scenario in which a substantial fraction of the LEE originates from bulk-related defects or microfractures within the detector crystal, while leaving room for additional detector-related contributions. Our result provides a powerful, data-driven pathway for mitigating LEE and enhancing the discovery potential of next-generation cryogenic experiments.

physics.ins-det

Low Energy Phonon Bursts Created By Fast Neutron Damage

Solid state athermal phonon calorimeters used in the search for low mass dark matter or coherent neutrino-nucleus interactions have long observed a large excess of events below several hundred eV. The relaxation of damage created by the interaction of fast cosmic ray neutrons with the detector has been proposed as a source of these excess events. By comparing neutron exposed detectors to control detectors, we report the first measurement of phonon bursts caused by damage created by fast neutrons. Differences in the spectral shape, the rate dependence on thermal history, and the observed spectral rate scaled to the neutron exposure between irradiated and control detectors suggest that our observed LEE backgrounds are not dominated by neutron damage-induced phonon bursts.

physics.ins-det

Characterization of a CsI(Tl) Scintillator Coupled to a SiPM at Cryogenic Temperatures

We report on the scintillation characterization of a 1 cm^3 CsI(Tl) crystal coupled to a 6 x 6 mm^2 SiPM read out with a custom transimpedance amplifier at cryogenic temperatures. The crystal was prepared with optical-grade surfaces and enclosed in a multi layer shielding system to suppress ambient light and background radiation. The detector response was studied at temperatures ranging from 100 K to room temperature. A figure of merit, defined as the ratio of the 59.5 keV peak position to the baseline resolution, showed a maximum at 175 K, indicating optimal photon detection efficiency. Pulse shape analysis demonstrated temperature-dependent variations in scintillation decay. At 175 K, the baseline resolution was sigma ~ 1 keV, corresponding to an effective threshold of ~ 3 keV. These results confirm the capability of the CsI(Tl) SiPM system to operate at low thresholds for rare-event searches and low-energy particle detection.

physics.ins-det

CE$\nu$NS Search with Cryogenic Sapphire Detectors at MINER: Results from the TRIGA reactor data and Future Sensitivity at HFIR

We report on a search for coherent elastic neutrino--nucleus scattering (CE$\nu$NS) using cryogenic sapphire (Al$_2$O$_3$) detectors deployed at the Mitchell Institute Neutrino Experiment at Reactor (MINER), located near the 1~MW$_\text{th}$ TRIGA research reactor at Texas A\&M University. The experiment operated with a primary detector mass of 72~g and achieved a baseline energy resolution of $\sim 40$~eV. Using exposures of 158~g-days (reactor-on) and 381~g-days (reactor-off), we performed a statistical background subtraction in the energy region of 0.25--3~keV. A GEANT4 simulation has been performed to understand the reactor-correlated background present in the data and it agrees with our observations. The resulting best-fit ratio of the observed CE$\nu$NS rate to the Standard Model prediction after rejecting the reactor induced background from the data with the help of simulation, is $\rho = 0.26\pm 1534.74~\mathrm{(stat)} \pm 0.05~\mathrm{(sys)}$ with a significance of $0.007 \pm 0.022~\mathrm{(stat)} \pm 0.001~\mathrm{(sys)}$. This low significance indicates a high background rate at low energies. To have enhanced sensitivity, the MINER collaboration plans to relocate the experiment to the 85~MW$_\text{th}$ High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL). With improved shielding, increased detector mass, and higher antineutrino flux, the upgraded setup is projected to achieve a 3$\sigma$ CE$\nu$NS detection within 30~kg$\cdot$days of exposure.

nucl-ex

Search for low-mass electron-recoil dark matter using a single-charge sensitive SuperCDMS-HVeV Detector

We present constraints on low-mass dark matter electron scattering and absorption interactions using a SuperCDMS high-voltage eV-resolution (HVeV) detector. Data were taken underground in the NEXUS facility located at Fermilab with an overburden of 225 meters of water equivalent. The experiment benefits from the minimizing of luminescence from the printed circuit boards in the detector holder used in all previous HVeV studies. A blind analysis of $6.1\,\mathrm{g\cdot days}$ of exposure produces exclusion limits for dark matter-electron scattering cross sections for masses as low as $1\,\mathrm{MeV}/c^2$, as well as on the photon-dark photon mixing parameter and the coupling constant between axionlike particles and electrons for particles with masses $>1.2\,\mathrm{eV}/c^2$ probed via absorption processes.

hep-ex

Multi-channel, multi-template event reconstruction for SuperCDMS data using machine learning

SuperCDMS SNOLAB uses kilogram-scale germanium and silicon detectors to search for dark matter. Each detector has Transition Edge Sensors (TESs) patterned on the top and bottom faces of a large crystal substrate, with the TESs electrically grouped into six phonon readout channels per face. Noise correlations are expected among a detector's readout channels, in part because the channels and their readout electronics are located in close proximity to one another. Moreover, owing to the large size of the detectors, energy deposits can produce vastly different phonon propagation patterns depending on their location in the substrate, resulting in a strong position dependence in the readout-channel pulse shapes. Both of these effects can degrade the energy resolution and consequently diminish the dark matter search sensitivity of the experiment if not accounted for properly. We present a new algorithm for pulse reconstruction, mathematically formulated to take into account correlated noise and pulse shape variations. This new algorithm fits N readout channels with a superposition of M pulse templates simultaneously - hence termed the N$\times$M filter. We describe a method to derive the pulse templates using principal component analysis (PCA) and to extract energy and position information using a gradient boosted decision tree (GBDT). We show that these new N$\times$M and GBDT analysis tools can reduce the impact from correlated noise sources while improving the reconstructed energy resolution for simulated mono-energetic events by more than a factor of three and for the 71Ge K-shell electron-capture peak recoils measured in a previous version of SuperCDMS called CDMSlite to $<$ 50 eV from the previously published value of $\sim$100 eV. These results lay the groundwork for position reconstruction in SuperCDMS with the N$\times$M outputs.

physics.ins-det

Low-Energy Calibration of SuperCDMS HVeV Cryogenic Silicon Calorimeters Using Compton Steps

Cryogenic calorimeters for low-mass dark matter searches have achieved sub-eV energy resolutions, driving advances in both low-energy calibration techniques and our understanding of detector physics. The energy deposition spectrum of gamma rays scattering off target materials exhibits step-like features, known as Compton steps, near the binding energies of atomic electrons. We demonstrate a successful use of Compton steps for sub-keV calibration of cryogenic silicon calorimeters, utilizing four SuperCDMS High-Voltage eV-resolution (HVeV) detectors operated with 0 V bias across the crystal. This new calibration at 0 V is compared with the established high-voltage calibration using optical photons. The comparison indicates that the detector response at 0 V is about 30% weaker than expected, highlighting challenges in detector response modeling for low-mass dark matter searches.

physics.ins-det

A GEANT4-Based Simulation of Directional Neutron Detectors Using Liquid Scintillators and Boron Carbide Moderators

We present a simulation-based study of a compact directional neutron detector composed of liquid scintillator, Cesium Iodide, with boron carbide (B4C) moderation, and silicon photomultipliers (SiPMs). Using GEANT4, we explored multiple detector geometries and material configurations, finding neutron detection efficiencies ranging from approximately 10% to 30%. To evaluate directionality, spatial energy distributions were analyzed and used to train a machine learning classifier, which achieved 100% accuracy in identifying neutron source directions along four cardinal axes. The model remained effective for sources near detector edges, demonstrating robustness. These results establish the feasibility of the proposed detector for applications in nuclear safety, environmental monitoring, and scientific research applications, with future work focused on experimental validation.

physics.ins-det

First Event-by-Event Identification of Cherenkov Radiation from Sub-MeV Particles in Liquid Argon

This Letter reports the event-by-event observation of Cherenkov light from sub-MeV electrons in a high scintillation light-yield liquid argon (LAr) detector by the Coherent CAPTAIN-Mills (CCM) experiment. The CCM200 detector, located at Los Alamos National Laboratory, instruments 7 tons (fiducial volume) of LAr with 200 8-inch photomultiplier tubes (PMTs), 80% of which are coated in a wavelength shifting material and the remaining 20% are uncoated. In the prompt time region of an event, defined as $-6 \leq t < 0$ ns relative to the event start time $t=0$, the uncoated PMTs are primarily sensitive to visible Cherenkov photons. Using gamma-rays from a $^{22}$Na source for production of sub-MeV electrons, we isolated prompt Cherenkov light with $>5\sigma$ confidence and developed a selection to obtain a low-background electromagnetic sample. This is the first event-by-event observation of Cherenkov photons from sub-MeV electrons in a high-yield scintillator detector, and represents a milestone in low-energy particle detector development.

physics.ins-det

Measurement of the Liquid Argon Scintillation Pulse Shape Using Differentiable Simulation in the Coherent CAPTAIN-Mills Experiment

The Coherent CAPTAIN-Mills (CCM) experiment is a liquid argon (LAr) light collection detector searching for MeV-scale neutrino and Beyond Standard Model physics signatures. Two hundred 8-inch photomultiplier tubes (PMTs) instrument the 7 ton fiducial volume with 50% photocathode coverage to detect light produced by charged particles. CCM's light-based approach reduces requirements of LAr purity, compared to other detection technologies, such that sub-MeV particles can be reliably detected without additional LAr filtration and with O(1) parts-per-million of common contaminants. We present a measurement of LAr light production and propagation parameters, with uncertainties, obtained from a sample of MeV-scale electromagnetic events. The optimization of this high-dimensional parameter space was facilitated by a differentiable optical photon Monte-Carlo simulation, and detailed PMT response characterization. This result accurately predicts the timing and spatial distribution of light due to scintillation and Cherenkov emission in the detector. This is the first description of photon propagation in LAr to include several effects, including: anomalous dispersion of the index of refraction near the ultraviolet resonance, Mie scattering from impurities, and Cherenkov light production.

physics.ins-det

Spontaneous generation of athermal phonon bursts within bulk silicon causing excess noise, low energy background events and quasiparticle poisoning in superconducting sensors

Solid state phonon detectors used in the search for dark matter and coherent neutrino nucleus interactions (CE$\nu$NS) require excellent energy resolution (eV-scale or below) and low backgrounds. An unknown source of phonon bursts, the low energy excess (LEE), dominates other above-threshold backgrounds and generates excess shot noise from sub-threshold bursts. In this paper, we measure these phonon bursts for 12 days after cooldown in two nearly identical 1 cm$^2$ silicon detectors that differ only in the thickness of their substrate (1 mm vs. 4 mm thick). We find that both the channel-correlated shot noise and near-threshold shared LEE relax with time since cooldown. Additionally, both the correlated shot noise and LEE rates scale linearly with substrate thickness. When combined with previous measurements of other silicon phonon detectors with different substrate geometries and mechanical support strategies, these measurements strongly suggest that the dominant source of both above and below threshold LEE is the bulk substrate. By monitoring the relation between bias power and excess phonon shot noise, we estimate that the energy scale for sub-threshold noise events is $0.68 \pm 0.38$ meV. In our final dataset, we report a world-leading energy resolution of 258.5$\pm$0.4 meV in the 1 mm thick detector. Simple calculations suggest that these silicon substrate phonon bursts are likely a significant source of quasiparticle poisoning in superconducting qubits operated in well shielded and vibration free environments.

physics.ins-det

MINER Reactor Based Search for Axion-Like Particles Using Sapphire (Al2O3) Detectors

The absence of definitive results for WIMP dark matter has sparked growing interest in alternative dark matter candidates, such as axions and Axion-Like Particles (ALPs), which also provide insight into the strong CP problem. The Mitchell Institute Neutrino Experiment at Reactor (MINER), conducted at the Nuclear Science Center of Texas A&M University, investigated ALPs near a 1 MW TRIGA nuclear reactor core, positioned approximately 4 meters away. This experiment employed cryogenic sapphire detectors with a low detection threshold (approximately 100 eV), equipped with a Transition Edge Sensor capable of detecting athermal phonons. Due to the low-background environment, we were able to exclude ALPs with axion-photon coupling and axion-electron coupling as small as \(g_{a\gamma\gamma} = 10^{-5}\) and \(g_{aee} = 10^{-7}\), respectively. Energy depositions below 3 keV were not considered and remain blinded for our Coherent Elastic Neutrino Nucleus Scattering (CEvNS) analysis. This is the first result demonstrating the MINER experiment's potential to probe low-mass ALPs, enabled by its low-threshold detector and proximity to a reactor.

hep-ex

First Limits on Light Dark Matter Interactions in a Low Threshold Two Channel Athermal Phonon Detector from the TESSERACT Collaboration

We present results of a search for spin-independent dark matter-nucleon interactions in a 1 cm$^2$ by 1 mm thick (0.233 gram) high-resolution silicon athermal phonon detector operated above ground. For interactions in the substrate, this detector achieves a r.m.s. baseline energy resolution of 361.5 $\pm$ 0.4 MeV/$c^2$, the best for any athermal phonon detector to date. With an exposure of 0.233g $\times$ 12 hours, we place the most stringent constraints on dark matter masses between 44 and 87 MeV/$c^2$, with the lowest unexplored cross section of 4 $\times 10^{-32}$ cm$^2$ at 87 MeV/$c^2$. We employ a conservative salting technique to reach the lowest dark matter mass ever probed via direct detection experiment. This constraint is enabled by two-channel rejection of low-energy backgrounds that are coupled to individual sensors.

hep-ex

Design Studies Of A Pulsed Quasimonoenergetic 2-keV Neutron Source For Calibration Of Low Threshold Dark Matter Detectors

We describe design studies for a pulsed quasi-monoenergetic 2-keV neutron source for calibration of sub-keV nuclear recoils. Such a calibration is required for detectors sensitive to sub-GeV dark matter and also the coherent elastic scattering of reactor neutrinos. In our design, neutrons from a commercial deuterium-tritium generator are moderated to the keV scale and then filtered to the monoenergetic spectrum using a feature in the neutron cross section of scandium. In this approach, unmoderated high-energy neutrons form a challenging background, along with gammas from neutron capture in the moderator materials. We describe the optimization of the moderator+filter and shielding geometry, and find a geometry that in simulation achieves both the target neutron flux at 2 keV and subdominant rates of background interactions. Lastly, we describe a future path to lower-energy (few eV scale) calibrations using time-of-flight and sub-keV neutrons.

physics.ins-det

Reactor-based Search for Axion-Like Particles using CsI(Tl) Detector

The absence of conclusive signals in weakly interacting massive particle (WIMP) searches has motivated increased interest in alternative dark matter candidates such as axions and axion-like particles (ALPs), which also provide a solution to the strong CP problem. In this work, we employ a $\sim100~\mathrm{kg}$ scale CsI(Tl)-based detector operated in proximity to a nuclear reactor to achieve a sub-100 DRU (differential rate unit, expressed in counts/keV/kg/day) background level in the MeV energy range through a combination of active veto and passive shielding techniques. Such a low-background environment enables sensitivity to ALPs with axion--photon coupling $g_{a\gamma\gamma} \gtrsim 10^{-6}$ and axion--electron coupling in the range $10^{-8} < g_{aee} < 10^{-4}$ for ALP masses between 1~keV and 10~MeV. These results demonstrate that the experiment has the potential to probe previously unexplored regions of parameter space, including the so-called cosmological triangle in the ALP--photon coupling for MeV-scale ALPs.

hep-ex

Light Dark Matter Constraints from SuperCDMS HVeV Detectors Operated Underground with an Anticoincidence Event Selection

This article presents constraints on dark-matter-electron interactions obtained from the first underground data-taking campaign with multiple SuperCDMS HVeV detectors operated in the same housing. An exposure of 7.63 g-days is used to set upper limits on the dark-matter-electron scattering cross section for dark matter masses between 0.5 and 1000 MeV/$c^2$, as well as upper limits on dark photon kinetic mixing and axion-like particle axioelectric coupling for masses between 1.2 and 23.3 eV/$c^2$. Compared to an earlier HVeV search, sensitivity was improved as a result of an increased overburden of 225 meters of water equivalent, an anticoincidence event selection, and better pile-up rejection. In the case of dark-matter-electron scattering via a heavy mediator, an improvement by up to a factor of 25 in cross-section sensitivity was achieved.

hep-ex