Searcharxiv⌕ Search

arXiv subjects

R. Mahapatra

Publications and source records attributed to R. Mahapatra.

At least 37 records · Page 2Linked to original sources

First Demonstration of the HeRALD Superfluid Helium Detector Concept

The SPICE/HeRALD collaboration is performing R&D to enable studies of sub-GeV dark matter models using a variety of target materials. Here we report our recent progress on instrumenting a superfluid $^4$He target mass with a transition-edge sensor based calorimeter to detect both atomic signals (scintillation) and $^4$He quasiparticle (phonon and roton) excitations. The sensitivity of HeRALD to the critical "quantum evaporation" signal from $^4$He quasiparticles requires us to block the superfluid film flow to the calorimeter. We have developed a heat-free film-blocking method employing an unoxidized Cs film, which we implemented in a prototype "HeRALD v0.1" detector of ~10 g target mass. This article reports initial studies of the atomic and quasiparticle signal channels. A key result of this work is the measurement of the quantum evaporation channel's gain of 0.15 $\pm$ 0.01, which will enable $^4$He-based dark matter experiments in the near term. With this gain the HeRALD detector reported here has an energy threshold of 145 eV at 5 sigma, which would be sensitive to dark matter masses down to 220 MeV/c$^2$.

physics.ins-det↗

Light Dark Matter Constraints from SuperCDMS HVeV Detectors Operated Underground with an Anticoincidence Event Selection

This article presents constraints on dark-matter-electron interactions obtained from the first underground data-taking campaign with multiple SuperCDMS HVeV detectors operated in the same housing. An exposure of 7.63 g-days is used to set upper limits on the dark-matter-electron scattering cross section for dark matter masses between 0.5 and 1000 MeV/$c^2$, as well as upper limits on dark photon kinetic mixing and axion-like particle axioelectric coupling for masses between 1.2 and 23.3 eV/$c^2$. Compared to an earlier HVeV search, sensitivity was improved as a result of an increased overburden of 225 meters of water equivalent, an anticoincidence event selection, and better pile-up rejection. In the case of dark-matter-electron scattering via a heavy mediator, an improvement by up to a factor of 25 in cross-section sensitivity was achieved.

hep-ex↗

Improved Modelling of Detector Response Effects in Phonon-based Crystal Detectors used for Dark Matter Searches

Various dark matter search experiments employ phonon-based crystal detectors operated at cryogenic temperatures. Some of these detectors, including certain silicon detectors used by the SuperCDMS Collaboration, are able to achieve single-charge sensitivity when a voltage bias is applied across the detector. The total amount of phonon energy measured by such a detector is proportional to the number of electron-hole pairs created by the interaction. However, crystal impurities and surface effects can cause propagating charges to either become trapped inside the crystal or create additional unpaired charges, producing non-quantized measured energy as a result. A new analytical model for describing these detector response effects in phonon-based crystal detectors is presented. This model improves upon previous versions by demonstrating how the detector response, and thus the measured energy spectrum, is expected to differ depending on the source of events. We use this model to extract detector response parameters for SuperCDMS HVeV detectors, and illustrate how this robust modelling can help statistically discriminate between sources of events in order to improve the sensitivity of dark matter search experiments.

physics.ins-det↗

Exploring Charge Transport Dynamics in a Cryogenic P-Type Germanium Detector

This study explores the dynamics of charge transport within a cryogenic P-type Ge particle detector, fabricated from a crystal cultivated at the University of South Dakota (USD). By subjecting the detector to cryogenic temperatures and an Am-241 source, we observe evolving charge dynamics and the emergence of cluster dipole states, leading to the impact ionization process at 40 mK. Our analysis focuses on crucial parameters: the zero-field cross-section of cluster dipole states and the binding energy of these states. For the Ge detector in our investigation, the zero-field cross-section of cluster dipole states is determined to be $8.45 \times 10^{-11}\pm 4.22\times 10^{-12}~cm^2$. Examination of the binding energy associated with cluster dipole states, formed by charge trapping onto dipole states during the freeze-out process, reveals a value of $0.034 \pm 0.0017$ meV. These findings shed light on the intricate charge states influenced by the interplay of temperature and electric field, with potential implications for the sensitivity in detecting low-mass dark matter.

physics.ins-det↗

Physics Opportunities at a Beam Dump Facility at PIP-II at Fermilab and Beyond

The Fermilab Proton-Improvement-Plan-II (PIP-II) is being implemented in order to support the precision neutrino oscillation measurements at the Deep Underground Neutrino Experiment, the U.S. flagship neutrino experiment. The PIP-II LINAC is presently under construction and is expected to provide 800~MeV protons with 2~mA current. This white paper summarizes the outcome of the first workshop on May 10 through 13, 2023, to exploit this capability for new physics opportunities in the kinematic regime that are unavailable to other facilities, in particular a potential beam dump facility implemented at the end of the LINAC. Various new physics opportunities have been discussed in a wide range of kinematic regime, from eV scale to keV and MeV. We also emphasize that the timely establishment of the beam dump facility at Fermilab is essential to exploit these new physics opportunities.

hep-ex↗

Prospects for detecting axionlike particles at the Coherent CAPTAIN-Mills experiment

We show results from the Coherent CAPTAIN Mills (CCM) 2019 engineering run which begin to constrain regions of parameter space for axion-like particles (ALPs) produced in electromagnetic particle showers in an 800 MeV proton beam dump, and further investigate the sensitivity of ongoing data-taking campaigns for the CCM200 upgraded detector. Based on beam-on background estimates from the engineering run, we make realistic extrapolations for background reduction based on expected shielding improvements, reduced beam width, and analysis-based techniques for background rejection. We obtain reach projections for two classes of signatures; ALPs coupled primarily to photons can be produced in the tungsten target via the Primakoff process, and then produce a gamma-ray signal in the Liquid Argon (LAr) CCM detector either via inverse Primakoff scattering or decay to a photon pair. ALPs with significant electron couplings have several additional production mechanisms (Compton scattering, $e^+e^-$ annihilation, ALP-bremsstrahlung) and detection modes (inverse Compton scattering, external $e^+e^-$ pair conversion, and decay to $e^+e^-$). In some regions, the constraint is marginally better than both astrophysical and terrestrial constraints. With the beginning of a three year run, CCM will be more sensitive to this parameter space by up to an order of magnitude for both ALP-photon and ALP-electron couplings. The CCM experiment will also have sensitivity to well-motivated parameter space of QCD axion models. It is only a recent realization that accelerator-based large volume liquid argon detectors designed for low energy coherent neutrino and dark matter scattering searches are also ideal for probing ALPs in the unexplored $\sim$MeV mass scale.

hep-ph↗

A Strategy for Low-Mass Dark Matter Searches with Cryogenic Detectors in the SuperCDMS SNOLAB Facility

The SuperCDMS Collaboration is currently building SuperCDMS SNOLAB, a dark matter search focused on nucleon-coupled dark matter in the 1-5 GeV/c$^2$ mass range. Looking to the future, the Collaboration has developed a set of experience-based upgrade scenarios, as well as novel directions, to extend the search for dark matter using the SuperCDMS technology in the SNOLAB facility. The experienced-based scenarios are forecasted to probe many square decades of unexplored dark matter parameter space below 5 GeV/c$^2$, covering over 6 decades in mass: 1-100 eV/c$^2$ for dark photons and axion-like particles, 1-100 MeV/c$^2$ for dark-photon-coupled light dark matter, and 0.05-5 GeV/c$^2$ for nucleon-coupled dark matter. They will reach the neutrino fog in the 0.5-5 GeV/c$^2$ mass range and test a variety of benchmark models and sharp targets. The novel directions involve greater departures from current SuperCDMS technology but promise even greater reach in the long run, and their development must begin now for them to be available in a timely fashion. The experienced-based upgrade scenarios rely mainly on dramatic improvements in detector performance based on demonstrated scaling laws and reasonable extrapolations of current performance. Importantly, these improvements in detector performance obviate significant reductions in background levels beyond current expectations for the SuperCDMS SNOLAB experiment. Given that the dominant limiting backgrounds for SuperCDMS SNOLAB are cosmogenically created radioisotopes in the detectors, likely amenable only to isotopic purification and an underground detector life-cycle from before crystal growth to detector testing, the potential cost and time savings are enormous and the necessary improvements much easier to prototype.

physics.ins-det↗

Observation of Time-Dependent Internal Charge Amplification in a Planar Germanium Detector at Cryogenic Temperature

For the first time, time-dependent internal charge amplification through impact ionization has been observed in a planar germanium (Ge) detector operated at cryogenic temperature. In a time period of 30 and 45 minutes after applying a bias voltage, the charge energy corresponding to a baseline of the 59.54 keV $γ$ rays from a $^{241}$Am source is amplified for a short period of time and then decreases back to the baseline. The amplification of charge energy depends strongly on the applied positive bias voltage with drifting holes across the detector. No such phenomenon is visible with drifting electrons across the detector. We find that the observed charge amplification is dictated by the impact ionization of charged states, which has a strong correlation with impurity level and applied electric field. We analyze the dominant physics mechanisms that are responsible for the creation and the impact ionization of charged states. Our analysis suggests that the appropriate level of impurity in a Ge detector can enhance charge yield through the impact ionization of charged states to achieve extremely low-energy detection threshold ($<$ 10 meV) for MeV-scale dark matter searches if the charge amplification can be stabilized.

physics.ins-det↗

First measurement of the nuclear-recoil ionization yield in silicon at 100 eV

We measured the nuclear--recoil ionization yield in silicon with a cryogenic phonon-sensitive gram-scale detector. Neutrons from a mono-energetic beam scatter off of the silicon nuclei at angles corresponding to energy depositions from 4\,keV down to 100\,eV, the lowest energy probed so far. The results show no sign of an ionization production threshold above 100\,eV. These results call for further investigation of the ionization yield theory and a comprehensive determination of the detector response function at energies below the keV scale.

physics.ins-det↗

A Search for Low-mass Dark Matter via Bremsstrahlung Radiation and the Migdal Effect in SuperCDMS

We present a new analysis of previously published of SuperCDMS data using a profile likelihood framework to search for sub-GeV dark matter (DM) particles through two inelastic scattering channels: bremsstrahlung radiation and the Migdal effect. By considering these possible inelastic scattering channels, experimental sensitivity can be extended to DM masses that are undetectable through the DM-nucleon elastic scattering channel, given the energy threshold of current experiments. We exclude DM masses down to $220~\textrm{MeV}/c^2$ at $2.7 \times 10^{-30}~\textrm{cm}^2$ via the bremsstrahlung channel. The Migdal channel search provides overall considerably more stringent limits and excludes DM masses down to $30~\textrm{MeV}/c^2$ at $5.0 \times 10^{-30}~\textrm{cm}^2$.

hep-ex↗

A portable and high intensity 24 keV neutron source based on $^{124}$Sb-$^{9}$Be photoneutrons and an iron filter

A portable monoenergetic 24 keV neutron source based on the $^{124}$Sb-$^9$Be photoneutron reaction and an iron filter has been constructed and characterized. The coincidence of the neutron energy from SbBe and the low interaction cross-section with iron (mean free path up to 29 cm) makes pure iron specially suited to shield against gamma rays from $^{124}$Sb decays while letting through the neutrons. To increase the $^{124}$Sb activity and thus the neutron flux, a $>$1 GBq $^{124}$Sb source was produced by irradiating a natural Sb metal pellet with a high flux of thermal neutrons in a nuclear reactor. The design of the source shielding structure makes for easy transportation and deployment. A hydrogen gas proportional counter is used to characterize the neutrons emitted by the source and a NaI detector is used for gamma background characterization. At the exit opening of the neutron beam, the characterization determined the neutron flux in the energy range 20-25 keV to be 5.36$\pm$0.20 neutrons per cm$^2$ per second and the total gamma flux to be 213$\pm$6 gammas per cm$^2$ per second (numbers scaled to 1 GBq activity of the $^{124}$Sb source). A liquid scintillator detector is demonstrated to be sensitive to neutrons with incident kinetic energies from 8 to 17 keV, so it can be paired with the source as a backing detector for neutron scattering calibration experiments. This photoneutron source provides a good tool for in-situ low energy nuclear recoil calibration for dark matter experiments and coherent elastic neutrino-nucleus scattering experiments.

physics.ins-det↗

Development of a large-mass, low-threshold detector system with simultaneous measurements of athermal phonons and scintillation light

We have combined two low-threshold detector technologies to develop a large-mass, low-threshold detector system that simultaneously measures the athermal phonons in a sapphire detector while an adjacent silicon high-voltage detector detects the scintillation light from the sapphire detector. This detector system could provide event-by-event discrimination between electron and nuclear events due to the difference in their scintillation light yield. While such systems with simultaneous phonon and light detection have been demonstrated earlier with smaller detectors, our system is designed to provide a large detector mass with high amplification for the limited scintillation light. Future work will focus on at least an order of magnitude improvement in the light collection efficiency by having a highly reflective detector housing and custom phonon mask design to maximize light collection by the silicon high-voltage detector.

physics.ins-det↗

Investigating the sources of low-energy events in a SuperCDMS-HVeV detector

Recent experiments searching for sub-GeV/$c^2$ dark matter have observed event excesses close to their respective energy thresholds. Although specific to the individual technologies, the measured excess event rates have been consistently reported at or below event energies of a few-hundred eV, or with charges of a few electron-hole pairs. In the present work, we operated a 1-gram silicon SuperCDMS-HVeV detector at three voltages across the crystal (0 V, 60 V and 100 V). The 0 V data show an excess of events in the tens of eV region. Despite this event excess, we demonstrate the ability to set a competitive exclusion limit on the spin-independent dark matter--nucleon elastic scattering cross section for dark matter masses of $\mathcal{O}(100)$ MeV/$c^2$, enabled by operation of the detector at 0 V potential and achievement of a very low $\mathcal{O}(10)$ eV threshold for nuclear recoils. Comparing the data acquired at 0 V, 60 V and 100 V potentials across the crystal, we investigated possible sources of the unexpected events observed at low energy. The data indicate that the dominant contribution to the excess is consistent with a hypothesized luminescence from the printed circuit boards used in the detector holder.

hep-ex↗

Ionization yield measurement in a germanium CDMSlite detector using photo-neutron sources

Two photo-neutron sources, $^{88}$Y$^{9}$Be and $^{124}$Sb$^{9}$Be, have been used to investigate the ionization yield of nuclear recoils in the CDMSlite germanium detectors by the SuperCDMS collaboration. This work evaluates the yield for nuclear recoil energies between 1 keV and 7 keV at a temperature of $\sim$ 50 mK. We use a Geant4 simulation to model the neutron spectrum assuming a charge yield model that is a generalization of the standard Lindhard model and consists of two energy dependent parameters. We perform a likelihood analysis using the simulated neutron spectrum, modeled background, and experimental data to obtain the best fit values of the yield model. The ionization yield between recoil energies of 1 keV and 7 keV is shown to be significantly lower than predicted by the standard Lindhard model for germanium. There is a general lack of agreement among different experiments using a variety of techniques studying the low-energy range of the nuclear recoil yield, which is most critical for interpretation of direct dark matter searches. This suggests complexity in the physical process that many direct detection experiments use to model their primary signal detection mechanism and highlights the need for further studies to clarify underlying systematic effects that have not been well understood up to this point.

physics.ins-det↗

Effective Field Theory Analysis of CDMSlite Run 2 Data

CDMSlite Run 2 was a search for weakly interacting massive particles (WIMPs) with a cryogenic 600 g Ge detector operated in a high-voltage mode to optimize sensitivity to WIMPs of relatively low mass from 2 - 20 GeV/$c^2$. In this article, we present an effective field theory (EFT) analysis of the CDMSlite Run 2 data using an extended energy range and a comprehensive treatment of the expected background. A binned likelihood Bayesian analysis was performed on the recoil energy data, taking into account the parameters of the EFT interactions and optimizing the data selection with respect to the dominant background components. Energy regions within 5$σ$ of known activation peaks were removed from the analysis. The Bayesian evidences resulting from the different operator hypotheses show that the CDMSlite Run 2 data are consistent with the background-only models and do not allow for a signal interpretation assuming any additional EFT interaction. Consequently, upper limits on the WIMP mass and coupling-coefficient amplitudes and phases are presented for each EFT operator. These limits improve previous CDMSlite Run 2 bounds for WIMP masses above 5 GeV/$c^2$.

astro-ph.CO↗

First Dark Matter Search Results From Coherent CAPTAIN-Mills

This paper describes the operation of the Coherent CAPTAIN-Mills (CCM) detector located at the Lujan Neutron Science Center (LANSCE) at Los Alamos National Laboratory (LANL). CCM is a 10-ton liquid argon (LAr) detector located 20 meters from a high flux neutron/neutrino source and is designed to search for sterile neutrinos ($ν_s$) and light dark matter (LDM). An engineering run was performed in Fall 2019 to study the characteristics of the CCM120 detector by searching for coherent scattering signals consistent with $ν_s$'s and LDM resulting from $π^+$ and $π^0$ decays in the tungsten target. New parameter space in a leptophobic dark matter model was excluded for DM masses between $\sim2.0$ and 30 MeV. The lessons learned from this run have guided the development and construction of the new CCM200 detector that will begin operations in 2021 and significantly improve on these searches.

hep-ex↗

First Leptophobic Dark Matter Search from Coherent CAPTAIN-Mills

We report the first results of a search for leptophobic dark matter (DM) from the Coherent CAPTAIN-Mills (CCM) liquid argon (LAr) detector. An engineering run with 120 photomultiplier tubes (PMTs) and $17.9 \times 10^{20}$ protons-on-target (POT) was performed in Fall 2019 to study the characteristics of the CCM detector. The operation of this 10-ton detector was strictly light-based with a threshold of 50 keV and used coherent elastic scattering off argon nuclei to detect DM. Despite only 1.5 months of accumulated luminosity, contaminated LAr, and non-optimized shielding, CCM's first engineering run already achieved sensitivity to previously unexplored parameter space of light dark matter (LDM) models with a baryonic vector portal. With an expected background of 115,005 events, we observe 115,005+16.5 events which is compatible with background expectations. For a benchmark mediator-to-dark matter mass ratio of $m_{_{V_B}}/m_χ=2.1$, DM masses within the range $9\,\text{MeV} \lesssim m_χ\lesssim 50\,\text{MeV}$ have been excluded at 90% C.L. in the leptophobic model after applying the Feldman-Cousins test statistic. CCM's upgraded run with 200 PMTs, filtered LAr, improved shielding, and ten times more POT will be able to exclude the remaining thermal relic density parameter space of this model, as well as probe new parameter space of other leptophobic DM models.

hep-ex↗

Scintillation yield from electronic and nuclear recoils in superfluid $^4$He

Superfluid $^4$He is a promising target material for direct detection of light ($<$ 1 GeV) dark matter. Possible signal channels available for readout in this medium include prompt photons, triplet excimers, and roton and phonon quasiparticles. The relative yield of these signals has implications for the sensitivity and discrimination power of a superfluid $^4$He dark matter detector. Using a 16~cm$^3$ volume of 1.75~K superfluid $^4$He read out by six immersed photomultiplier tubes, we measured the scintillation from electronic recoils ranging between 36.3 and 185 keV$_\mathrm{ee}$, yielding a mean signal size of $1.25^{+0.03}_{-0.03}$~phe/keV$_\mathrm{ee}$, and nuclear recoils from 53.2 to 1090 keV$_\mathrm{nr}$. We compare the results of our relative scintillation yield measurements to an existing semiempirical model based on helium-helium and electron-helium interaction cross sections. We also study the behavior of delayed scintillation components as a function of recoil type and energy, a further avenue for signal discrimination in superfluid $^4$He.

physics.ins-det↗