SearcharxivSearch

arXiv subjects

R. Schwartz

Publications and source records attributed to R. Schwartz.

7 recordsLinked to original sources

Programmable CMOS DAC Operating in Cryogenic Environments for Controlling Superconducting Qubits

This paper presents the design and test results of a CMOS current-based Digital to Analog Converter (DAC) that operates at cryogenic temperatures and that can be used to precisely control the amount of flux coupled to qubits or that can be used in the readout of superconducting circuits. The current pulse output can be controlled in terms of its amplitude, rise and fall slopes, via digital controls, and pulse width, via external triggers, while driving a superconducting circuit. The design has been implemented in a planar 90 nm CMOS process and test results closely match circuit predictions. The solution's wide degree of digital tunability affords potential application of the same device to many types of quantum circuits, beyond those discussed here. Due to the wide-ranging flexibility of digital CMOS control, we envision that this DAC design will enable the next generation of high-fidelity cryo-CMOS control architectures for superconducting qubits.

quant-ph

Controlling instrumental systematics for the BICEP inflation survey

The BICEP series of experiments has been observing CMB polarisation from the South Pole for over 20 years, with the goal of constraining inflationary gravitational waves. The upcoming data release, using data taken through 2024, is forecasted to constrain the tensor-to-scalar ratio $r$ at the level of $\sigma(r) \sim 0.005$ (including delensing), with the longer-term goal of reaching $\sigma(r) \sim 0.001$ by 2034. As the survey sensitivity increases, it is crucial to control instrumental systematics to unprecedented levels, and our goal is to limit dominant sources of systematics to 20% of $\sigma(r)$ or lower. Achieving this requires careful instrumental characterisation and dedicated end-to-end studies to evaluate the impact of each systematic on cosmological parameters. We first present the BICEP calibration program, which characterises the optical, spectral, and polarisation response of the receivers. We then describe the analysis strategies implemented to identify and mitigate systematic contamination, and we detail simulations used to evaluate the impact of residual effects. We focus in particular on beam systematics, the dominant source of systematics for BICEP receivers. Finally, we report preliminary estimates of the expected level of systematic contamination for upcoming BICEP results, and we discuss approaches to evaluate and mitigate instrumental systematics for future surveys.

astro-ph.CO

BICEP/Keck XX: Component-separated maps of polarized CMB and thermal dust emission using Planck and BICEP/Keck Observations through the 2018 Observing Season

We present component-separated polarization maps of the cosmic microwave background (CMB) and Galactic thermal dust emission, derived using data from the BICEP/Keck experiments through the 2018 observing season and Planck. By employing a maximum-likelihood method that utilizes observing matrices, we produce unbiased maps of the CMB and dust signals. We outline the computational challenges and demonstrate an efficient implementation of the component map estimator. We show methods to compute and characterize power spectra of these maps, opening up an alternative way to infer the tensor-to-scalar ratio from our data. We compare the results of this map-based separation method with the baseline BICEP/Keck analysis. Our analysis demonstrates consistency between the two methods, finding an 84% correlation between the pipelines.

astro-ph.CO

Two-color Kerr microscopy of two-dimensional materials with sub-picosecond time resolution

We present a two-color Kerr microscopy system based on two electronically synchronized erbium-fiber laser oscillators with independently tunable emission energies spanning most of the visible spectrum. Combining a spatial resolution below 2 $μ$m and sub-ps time resolution with high sensitivity and cryogenic sample temperatures, it is ideally suited for studying spin and valley dynamics in a wide range of two-dimensional materials. We illustrate its capabilities by studying a monolayer of the common semiconducting transition metal disulfide MoS$_2$.

cond-mat.mes-hall

Laser wakefield acceleration with mid-IR laser pulses

We report on the first results of laser plasma wakefield acceleration driven by ultrashort mid-infrared laser pulses (λ= 3.9 μm, 100 fs, 0.25 TW), which enable near- and above-critical density interactions with moderate-density gas jets. Relativistic electron acceleration up to ~12 MeV occurs when the jet width exceeds the threshold scale length for relativistic self-focusing. We present scaling trends in the accelerated beam profiles, charge and spectra, which are supported by particle-in-cell simulations and time-resolved images of the interaction. For similarly scaled conditions, we observe significant increases in accelerated charge compared to previous experiments with near-infrared (λ=800 nm) pulses.

physics.plasm-ph

ECFA Detector R&D Panel, Review Report

Two special calorimeters are foreseen for the instrumentation of the very forward region of an ILC or CLIC detector; a luminometer (LumiCal) designed to measure the rate of low angle Bhabha scattering events with a precision better than 10$^{-3}$ at the ILC and 10$^{-2}$ at CLIC, and a low polar-angle calorimeter (BeamCal). The latter will be hit by a large amount of beamstrahlung remnants. The intensity and the spatial shape of these depositions will provide a fast luminosity estimate, as well as determination of beam parameters. The sensors of this calorimeter must be radiation-hard. Both devices will improve the e.m. hermeticity of the detector in the search for new particles. Finely segmented and very compact electromagnetic calorimeters will match these requirements. Due to the high occupancy, fast front-end electronics will be needed. Monte Carlo studies were performed to investigate the impact of beam-beam interactions and physics background processes on the luminosity measurement, and of beamstrahlung on the performance of BeamCal, as well as to optimise the design of both calorimeters. Dedicated sensors, front-end and ADC ASICs have been designed for the ILC and prototypes are available. Prototypes of sensor planes fully assembled with readout electronics have been studied in electron beams.

physics.ins-det