Searcharxiv⌕ Search

arXiv subjects

Rajendra Nath Patra

Publications and source records attributed to Rajendra Nath Patra.

10 recordsLinked to original sources

Influence of Radiation and AC Coupling on Time Performance of Analog Pixels Test Structures in 65 nm CMOS technology

Monolithic Active Pixel Sensors (MAPS) in advanced CMOS imaging technologies are key to next-generation tracking systems for high-energy physics, where radiation hardness and precise vertex reconstruction are essential. As part of the ALICE ITS3 R&D program in synergy with the CERN R&D, we evaluated the performance of the Analog Pixel Test Structures (APTS) fabricated in the TPSCo 65 nm CMOS imaging process. The prototypes employ 10 um pitch pixels with a fast operational amplifier-based buffering stage at the output, enabling direct characterization of intrinsic sensor response. Beam tests with minimum ionizing particles assessed the timing and charge collection of DC- and AC-coupled designs, including devices exposed to 10^14 NIEL and 10^15 NIEL non ioninsing energy loss. DC-coupled sensors demonstrated stable performance, maintaining time resolution lower than 70 ps and >99% detection efficiency up to 10^15 NIEL. AC-coupled sensors demonstrated a wide operational margin, with efficiencies above 99% for clusterization thresholds below 150 electrons. Even though the AC coupling allows higher reverse bias than DC-coupled sensors, the reduced signal amplitude lowers the signal-to-noise ratio, increasing the jitter contribution. At high reverse bias, the AC-coupled sensors achieve time resolutions comparable to the DC-coupled version, demonstrating the viability of both approaches. These results also suggest that combining the low capacitance of DC-coupled designs with the high-bias capability of AC coupling could further enhance time resolution. These results confirm the suitability of 65 nm MAPS for future collider detectors requiring high radiation tolerance, efficiency, and timing precision.

physics.ins-det↗

Characterisation of the first wafer-scale prototype for the ALICE ITS3 upgrade: the monolithic stitched sensor (MOSS)

This paper presents the characterisation and testing of the first wafer-scale monolithic stitched sensor (MOSS) prototype developed for the ALICE ITS3 upgrade that is to be installed during the LHC Long Shutdown 3 (2026-2030). The MOSS chip design is driven by the truly cylindrical detector geometry that imposes that each layer is built out of two wafer-sized, bent silicon chips. The stitching technique is employed to fabricate sensors with dimensions of 1.4 $\times$ 25.9 cm, thinned to 50 $μ$m. The chip architecture, in-pixel front-end, laboratory and in-beam characterisation, susceptibility to single-event effects, and series testing are discussed. The testing campaign validates the design of a wafer-scale stitched sensor and the performance of the pixel matrix to be within the ITS3 requirements. The MOSS chip demonstrates the feasibility of the ITS3 detector concept and provides insights for further optimisation and development.

physics.ins-det↗

Time performance of Analog Pixel Test Structures with in-chip operational amplifier implemented in 65 nm CMOS imaging process

In the context of the CERN EP R&D on monolithic sensors and the ALICE ITS3 upgrade, the Tower Partners Semiconductor Co (TPSCo) 65 nm process has been qualified for use in high energy physics, and adopted for the ALICE ITS3 upgrade. An Analog Pixel Test Structure (APTS) featuring fast per pixel operational-amplifier-based buffering for a small matrix of four by four pixels, with a sensor with a small collection electrode and a very non-uniform electric field, was designed to allow detailed characterization of the pixel performance in this technology. Several variants of this chip with different pixel designs have been characterized with a (120 GeV/$c$) positive hadron beam. This result indicates that the APTS-OA prototype variants with the best performance achieve a time resolution of 63 ps with a detection efficiency exceeding 99% and a spatial resolution of 2 $μ$m, highlighting the potential of TPSCo 65nm CMOS imaging technology for high-energy physics and other fields requiring precise time measurement, high detection efficiency, and excellent spatial resolution.

physics.ins-det↗

Collective phenomena study in small systems using the bulk of particle production in high-multiplicity pp collisions at $\sqrt{s}=$ 13 TeV with ALICE

The heavy-ion collisions (A--A) at the Large Hadron Collider (LHC) energies have confirmed the production of the quark-gluon plasma (QGP), a new state of nuclear matter where quarks and gluons are deconfined. The light-flavour hadrons ($π$, K, p), constitute the bulk of the produced particles, carry useful information of the collision geometry, collective behaviour and thermal property of the QGP. The measurements of light-flavour hadron production in small collision systems (pp and p--A) at the LHC energies have shown the onset of collective phenomena (e.g. radial flow and long-range correlations) that resemble what is typically observed in nucleus-nucleus collisions and attributed to the formation of a deconfined system of quarks and gluons. The new results of the identified light-flavour particle production measured in high-multiplicity triggered pp collisions at $\sqrt{s}=13$~TeV of ALICE Run 2 will be presented in search of collective behaviour in small collision systems. The transverse momenta $p_{\rm T}$-spectra of the identified particles show hardening at the mid-$p_{\rm T}$. The mean transverse momenta ($\langle p_{\rm T} \rangle$) are shown as a function of charged-particle multiplicity. The ratios of $p_{\rm T}$-spectra and the ratios of the integrated yields of kaon- and proton-to-pion are also presented and compared with published results.

nucl-ex↗

Centrality, transverse momentum and collision energy dependence of the Tsallis parameters in relativistic heavy-ion collisions

The thermodynamic properties of matter created in high-energy heavy-ion collisions have been studied in the framework of the non-extensive Tsallis statistics. The transverse momentum ($p_{\rm T}$)~spectra of identified charged particles (pions, kaons, protons) and all charged particles from the available experimental data of Au-Au collisions at the Relativistic Heavy Ion Collider (RHIC) energies and Pb-Pb collisions at the Large Hadron Collider (LHC) energies are fitted by the Tsallis distribution. The fit parameters, $q$ and $T$ measure the degree of deviation from an equilibrium state and the effective temperature of the thermalized system, respectively. The $p_{\rm T}$~spectra are well described by the Tsallis distribution function from peripheral to central collisions for the wide range of collision energies, from $\sqrt{s_{\rm NN}}$ = 7.7 GeV to 5.02 TeV. The extracted Tsallis parameters are found to be dependent on the particle species, collision energy, centrality, and fitting ranges in $p_{\rm T}$. For central collisions, both $q$ and $T$ depend strongly on the fit ranges in $p_{\rm T}$. For most of the collision energies, $q$ remains almost constant as a function of centrality, whereas $T$ increases from peripheral to central collisions. For a given centrality, $q$ systematically increases as a function of collision energy whereas $T$ has a decreasing trend. A profile plot of $q$ and $T$ with respect to collision energy and centrality shows an anti-correlation between the two parameters.

hep-ph↗

Fabrication and beam test of a silicon-tungsten electromagnetic calorimeter

A silicon-tungsten (Si-W) sampling calorimeter, consisting of 19 alternate layers of silicon pad detectors (individual pad area of 1~cm$^2$) and tungsten absorbers (each of one radiation length), has been constructed for measurement of electromagnetic showers over a large energy range. The signal from each of the silicon pads is readout using an ASIC with a dynamic range from $-300$~fC to $+500$~fC. Another ASIC with a larger dynamic range, $\pm 600$~fC has been used as a test study. The calorimeter was exposed to pion and electron beams at the CERN Super Proton Synchrotron (SPS) to characterise the response to minimum ionising particles (MIP) and showers from electromagnetic (EM) interactions. Pion beams of 120 GeV provided baseline measurements towards the understanding of the MIP behaviour in the silicon pad layers, while electron beams of energy from 5 GeV to 60 GeV rendered detailed shower profiles within the calorimeter. The energy deposition in each layer, the longitudinal shower profile, and the total energy deposition have been measured for each incident electron energy. Linear behaviour of the total measured energy ($E$) with that of the incident particle energy ($E_{0}$) ensured satisfactory calorimetric performance. For a subset of the data sample, selected based on the cluster position of the electromagnetic shower of the incident electron, the dependence of the measured energy resolution on $E_{0}$ has been found to be $σ/E = (15.36/\sqrt{E_0(\mathrm{GeV)}} \oplus 2.0) \%$.

physics.ins-det↗

Characteristic study of a quadruple GEM detector and its comparison with a triple GEM detector

A quadruple GEM detector has been assembled in a standalone configuration and operated using Ar and CO$_2$ gas mixtures in proportions of 70:30 and 90:10. Detailed performance study of the detector has been made by using $^{106}$Ru-Rh $β$-source and X-ray spectrum of $^{55}$Fe source. Results of these measurements are presented in terms of gain, efficiency, energy and time resolutions and also compared with our earlier triple GEM results. The energy resolution has been found to be somewhat worse compared with that of the triple-GEM detector. Effect of drift field on electron transparency and time resolution has been studied in detail.

physics.ins-det↗

Time resolution and characteristic study of MWPC detectors with different Argon based gas

A prototype of Multi-Wire Proportional Chambers (MWPC) has been fabricated for the study of its various characteristics. The detector contains gold-coated tungsten wires (20 $μm$ diameter) on the anode frame, with a pitch of 2.8 mm. The gap between the anode and the cathode is 3 mm and the gap between anode and read-out is also 3 mm. Detailed study of MWPC in terms of gain, energy and timing resolution and efficiency measurements have been performed. The detector has been operated using Ar/CO$_{2}$ gas mixtures with 70:30 and 90:10 ratio. Energy spectrum of $^{55}$Fe X-ray source is obtained for the detector. The gain and energy resolution of the detector were calculated using X-ray spectrum. Time resolution is obtained $\sim$10 ns.

physics.ins-det↗

Measurement of basic characteristics and gain uniformity of a triple GEM detector

Large area Gas Electron Multiplier (GEM) detectors have been the preferred choice for tracking devices in major nuclear and particle physics experiments. Uniformity over surface of the detector in terms of gain, energy resolution and efficiency is crucial for the optimum performance of these detectors. In the present work, detailed performance study of a 10x10 cm^2 triple GEM detector operated using Ar and CO_2 gas mixtures in proportions of 70:30 and 90:10, has been made by making a voltage scan of the efficiency with 106^Ru-Rh beta-source and cosmic rays. The gain and energy resolution of the detector were studied using the X-ray spectrum of 55^Fe source. The uniformity of the detector has been investigated by dividing the detector in 7x7 zones and measuring the gain and energy resolution at the center of each zone. The variations of the gain and energy resolution have been found to be 8.8% and 6.7%, respectively. These studies are essential to characterise GEM detectors before their final use in the experiments.

physics.ins-det↗

Characterizations of GEM detector prototype

At NISER-IoP detector laboratory an initiative is taken to build and test Gas Electron Multiplier (GEM) detectors for ALICE experiment. The optimisation of the gas flow rate and the long-term stability test of the GEM detector are performed. The method and test results are presented.

physics.ins-det↗