Design and Performance Evaluation of a Quad-panel Dual-isotope PET Imaging System

In simultaneous dual-isotope PET, prompt-gamma-based separation is challenged by the low statistics of triple coincidences and the limited flexibility of coincidence logic for multi-energy event extraction. We designed and evaluated a compact quad-panel dual-isotope PET system without dedicated prompt gamma detectors. The system comprised four orthogonally arranged detector panels, each providing an effective area of 107.0 * 145.5 mm. GPU-accelerated software coincidence processing extracted double- and prompt-gamma-tagged triple coincidences from raw single-photon data. Triple-coincidence images were reconstructed with correlated-random-triple correction using the consistent delayed expectation-maximization method, followed by image-domain isotope separation using a spatially varying scaling factor. System performance was evaluated using phantom and in vivo studies, with emphasis on 68Ga/18F imaging because of the low prompt gamma yield. The system achieved energy resolutions of 15.7%, 12.9% and 10.2% at 511, 1077, and 1275 keV, and a timing resolution of 1.35 ns. In the 68Ga Derenzo, 1.6-mm rods were resolved in double-coincidence images, with 1.2-mm rods partially distinguishable, while 1.6-mm rods remained discernible in triple-coincidence images. The mean prompt gamma detection efficiencies along the three axes ranged from 8.19% to 9.31%. The system sensitivity was 1.12% for doubles with an energy window of 350-650 keV, and 0.068% for triples after random correction with a dual-energy window. The scatter fraction was 27.81%, and the NECR reached 83 kcps at 9.38 MBq for doubles and 106 cps at 21.42 MBq for triples. Phantom and in vivo studies demonstrated successful separation of 18F/68Ga and 18F/124I tracer distributions. By maintaining high-resolution and quantitative imaging performance, the system provides a preclinical platform for multitracer PET studies.

physics.med-ph↗

Joint Poisson Reconstruction for Prompt-Gamma-Enabled 68Ga/18F Dual-Isotope Quantitative PET Imaging

Objective:To enable simultaneous quantitative 68Ga/18F PET imaging despite low prompt-gamma triple-coincidence counts and random-triple contamination. Methods: We developed an expectation-maximization reconstruction method (PNR-EM) that jointly estimates pure-emitter, non-pure-emitter, and random-triple components using a Poisson model of prompt double, prompt triple, and delayed triple measurements. A consistent-delay strategy estimates random triples while preserving true-pair temporal correlations. Prompt doubles additionally constrain the non-pure component, and total variation regularization suppresses reconstruction noise. The method was evaluated with quantitative and Derenzo phantoms, a nine-well separation phantom, and tumor-bearing mice. Results: Phantom quantitation showed strong linearity (r2>0.99) and a maximum relative deviation below 9.9% relative to single-isotope references. The separated images largely preserved rod resolvability relative to their corresponding single-isotope references. The best PSNR, SSIM, and RMSE were 33.72 dB, 0.975, and 0.0206 for 18F, and 34.86 dB, 0.955, and 0.0181 for 68Ga in the 9-well phantom. The 68Ga RMSE was 41.4% lower than that of the best image-domain separation baseline. Tumor-bearing mouse imaging demonstrated in vivo separation of 68Ga-DOTA-NOC and 18F-FDG distributions. Conclusion: Joint estimation improved dual-isotope separation under the evaluated low-count conditions. Significance: To our knowledge, this study provides the first experimental demonstration of simultaneous 68Ga/18F PET separation using prompt-gamma coincidences, supporting simultaneous imaging of complementary metabolic and receptor-targeted tracer distributions.

physics.med-ph↗